1. Catalogs
  2. BeaconMedaes
  3. Flexible, Rigid and Retractable Pendants HTM/ISO Specification Sheet
video corpo

Flexible, Rigid and Retractable Pendants HTM/ISO Specification Sheet

Flexible, Rigid and Retractable Pendants HTM/ISO Specification Sheet

Flexible, Rigid and Retractable Pendants HTM/ISO Specification Sheet

Product catalog summary
Overview: The document provides specifications for Atlas Copco Medical's Rigid and Retractable Pendants, designed for use in operating theatres and anaesthetic rooms. These pendants deliver medical gases, electrical power, data, and extra low voltage services in a prefabricated assembly.
Specifications: The pendants are pre-piped, pre-wired, and fully tested, ensuring a 2000mm clearance above the finished floor level in the retracted position. They comply with HTM 2022, HTM02-01 NHS Model Engineering Specification C11, BS EN ISO 11197, and IEE Wiring Regulations. The body is made from 1.6mm thick Zintec steel with a RAL9002 polyester powder-coated finish, and the gas fascia plate is made from 2mm thick grade 304 stainless steel.
Design and Installation: The pendants can be surface or concealed mounted, with adjustable shrouds to accommodate ceiling thickness variations. They are octagonal, capable of mounting up to 8 medical gas/vacuum terminal units, and include BeaconMedæs GEM terminal units for gas services.
CE Marking: The pendants are CE marked under the Medical Devices Directive 93/42/EEC, classified as Class IIa Medical Devices.
Retractable Pendant: Features include a vertical range of 300mm extension/retraction at 20mm/s, powered by a single-phase linear actuator. It operates on a 230V, 50 Hz power supply, with a 12V remote hand controller and thermal overload protection.
Rigid Pendant: Rigidly piped according to BS EN ISO 11197, without flexible hoses. It accommodates up to 9 gas pipes, made from phosphorous de-oxidised non-arsenical copper, cleaned and degreased to BS EN ISO 15001 standards.
Flexible Pendants: Designed for ergonomic use in medical settings, they prevent trip hazards from trailing hoses. They are pressure and leak tested, complying with HTM 02-01, HTM 2022, and NHS Model Engineering Specification C11.
Note: Specifications are subject to change for product improvement. Contact Atlas Copco Medical for the latest information.
See more

Catalog excerpts

Flexible, Rigid and Retractable Pendants HTM/ISO Specification Sheet-1

Flexible, Rigid and Retractable Pendants SPECIFICATION Retractable Pendants Rigid & Retractable Pendants The pendant shall be designed for installation into operating theatres and anaesthetic rooms, providing medical gases, electrical power, data and extra low voltage services as specified by the customer, in a convenient prefabricated assembly. The pendant shall be supplied pre-piped, pre-wired and fully tested. Pendants shall be manufactured and installed to provide a 2000mm clearance above finished floor level (in retracted position for retractable pendants). The pendant shall fully comply with HTM 2022, HTM0201 NHS Model Engineering Specification C11, BS EN ISO 11197 and the IEE Wiring The pendant shall be capable of surface of concealed mounting, with a shroud extension being provided for surface installations. A separate shroud shall be supplied to enclose the 1st fix mounting arrangement, electrical terminations and gas service connections. The shroud shall be adjustable to compensate for variation in the finished ceiling thickness. The standard range of BeaconMedæs Flexible, Rigid and Retractable Pendants are ‘CE’ marked under the Medical Devices Directive 93/42/ EEC with approval from notified body no. 0088 (Lloyd’s Register Quality Assurance). Under this directive, the specified products are classified as Class IIa Medical Devices. U nde rside of false ceiling 5 00 square over shroud Retractable Pendant Atlas Copco Ltd. trading as Atlas Copco Medical Unit 18 Nuffield Way, Abingdon, Oxfordshire, UK OX14 1RL www.beaconmedaes.com T yp ical surface m ou nted in sta llation S up po rt S tructu re L oa dings H orizon ta l - 12 00 N V ertica l - 32 00 N M in . p u llo u t lo a d re q u ired per fixing - 3500 N T yp ical con ce aled m ou nted in sta llation 2 00 in re tracte d position 5 00 in exte nd ed position The Retractable Pendant shall be supplied with flexible hoses manufactured to BS EN ISO 5359, with NIST connectors manufactured to BS EN ISO 18082. Gas-specific NIST fittings shall be permanently attached. Pressure gas systems shall incorporate a self-closing check valve in the 1st fix termination to enable hose replacement without disruption of the system. Hoses shall have a minimum internal bore of 6.35mm (1/4”) for all pressure gases except surgical air, which shall have a minimum internal bore of 8.02mm in order to provide a higher flow/lower pressure drop for surgical tools. Vacuum hoses shall also have a minimum internal bore of 8.02mm. M 12 screw ed rod, nuts & w ashe rs for fixin g to structu ra l ce ilin g supplied b y others 7 40 m in im um , 15 00 m axim um len gth (in re tracte d position) The pendants shall be octagonal in section, capable of mounting up to 8 medical gas/vacuum terminal units plus an anaesthetic gas scavenging terminal unit, along with 8 double gang and 8 single gang electric sockets/devices. Medical gas/vacuum services shall incorporate BeaconMedæs GEM terminal units and the anaesthetic gas scavenging disposal system shall incorporate a BeaconMedæs terminal unit to BS EN ISO 9170-2. Medical gas/vacuum services shall be arranged in accordance with HTM 2022 and HTM02-01 recommendations. Electrical installations shall conform to the IEE wiring regulations and BS EN ISO 11197, routed through flexible conduit and terminate in a junction box. Actu ator su pp ly te rm ina l bo x (if fitte d) The body of the pendant shall be manufactured from 1.6mm thick Zintec steel. The pendant body shall be supplied with an ‘easy clean’ high quality RAL9002 polyester powder coated finish. The gas fascia plate shall be manufactured in 2mm thick grade 304 stainless steel and shall have a non-reflective satin brushed grain finish. All pendants shall have a soft bumper strip around the

 Open the catalog to page 1
Flexible, Rigid and Retractable Pendants HTM/ISO Specification Sheet-2

Rigid Pendants A Structru al ceiling M 1 2 scre w e d ro d, n uts & w ash ers fo r fixin g to stru ctu ra l ceiling su pplied b y o thers Stru ctura l ceiling The retractable pendant shall extend and retract through a vertical range of 300mm at an approximate rate of 20mm/s and shall be powered by a single-phase linear actuator. The linear actuator shall operate from a 230V, 50 Hz electrical power supply (110V, 60 Hz also available) fused at 5A. An extra-low voltage (12V) remote hand controller shall operate the pendant and internal micro-switches shall break the control circuit at the limits...

 Open the catalog to page 2
Flexible, Rigid and Retractable Pendants HTM/ISO Specification Sheet-3

Rigid/Retractable Pendant Order SheetPendant Type | Customer/Project [ Pendant quantity | Company Name [ Contact Person [ Date Added [ Required Date | ]of this configuration .e. Mounted on a Solid Ceiling Pendant Styie : I Painted jRAL9002) I Stainless Steel : Accessories: Medical Rail* Yes / No IV Hooks Yes i No Gases Section Input/Selection Required Electrical Section Viewed from Underside of Pendant Finished Floor Level Finished Floor Level Rigid Pendant Retractable Pendant Note: All Retractable Pendants have a single piece of Medical Rail fitted for Hand Controller Placement Maximum number...

 Open the catalog to page 3
Flexible, Rigid and Retractable Pendants HTM/ISO Specification Sheet-4

In an effort to continuously improve our products, the right is reserved to change the specification of the items described herein at any time. Please contact us for further information and up to date specifications. Atlas Copco Ltd. trading as Atlas Copco Medical Unit 18 Nuffield Way, Abingdon, Oxfordshire, UK OX14 1RL www.beaconmedaes.com

 Open the catalog to page 4

All BeaconMedaes catalogs and technical brochures

  1. Central alarm

    4  Pages

  2. Magnis MSV

    2  Pages

  3. mVAC

    12  Pages

Archived catalogs

  1. Local alarm

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.