1. Catalogs
  2. BeaconMedaes
  3. Flow Meters and Vacuum Regulators HTM/ISO Specification Sheet
video corpo

Flow Meters and Vacuum Regulators HTM/ISO Specification Sheet

Flow Meters and Vacuum Regulators HTM/ISO Specification Sheet

Flow Meters and Vacuum Regulators HTM/ISO Specification Sheet

Product catalog summary
Terminal Unit Connections: Flowmeters and vacuum suction units are supplied with connection probes compliant with BS 5682: 1998. Other standards such as DIN, NFPA, AFNOR, JIS, and ISO are available upon request. Extra long probes are recommended for use with bedhead trunking systems to avoid connectivity issues.
Gas Specificity: Devices are equipped with gas-specific probes to ensure correct assembly and prevent cross-connection of parts from different gases.
Materials: Flowmeters are constructed from chromium-plated brass, polycarbonate, and stainless steel. Vacuum suction devices use ABS, polycarbonate, and chrome-plated brass. Oxygen regulators are made from chrome-plated brass and aluminium.
Sterilising Specification: SafetyTrap® and DISS adapters can be steam sterilized. SafetyTrap® PC can be sterilized up to 40 times, PSU up to 100 times, and DISS adapters an unlimited number of times. Humidifiers should be autoclaved at 121 ºC for 25 minutes.
Warranty: A two-year warranty is provided, contingent on routine maintenance by competent personnel.
CE Marking: Products are CE marked under the Medical Devices Directive 93/42/EEC as Class IIa Medical Devices.
Technical Specifications: Flowmeters are available in single, double, and selector models with precision of ±10%. Vacuum regulating units are available in high and low suction models with precision of ±5%. Venturi vacuum units are also available internationally.
Accessories: Includes universal rail clamps, wall brackets, connectors, face masks, nasal cannulas, and humidifiers.
Oxygen Regulators: Available with supply pressure of 300 bar and outlet pressure of 4.5 ±0.5 bar, supporting flow rates up to 250 l/min.
Portable Electrical Suction Units: Various models are available with different vacuum and flow specifications, power requirements, and battery options.
Repair and Maintenance: Repair kits and replacement parts are available for flowmeters and vacuum suction devices.
See more

Catalog excerpts

Flow Meters and Vacuum Regulators HTM/ISO Specification Sheet-1

SOT Flowmeter and Vacuum Regulator Unit SPECIFICATION Terminal Unit Connections Flowmeter’s and vacuum suction units shall be supplied with connection probes to BS 5682: 1998. Other norms are available upon request but shall include: DIN German, NFPA American - DISS, Diamond, Latch and Geometric (P.B), AFNOR French, JIS Japanese, SS Swedish, Uni Italian,ISO European and AGA - other types are available upon request. Note - where flow meters or suction devices are connected to medical gas terminal units installed within bedhead trunking systems, on occasion there can be problems with clearance and the connection of humidifiers/collection jars. In these instances an extra long probe shall be available. Please consult with the bedhead trunking supplier as BeaconMedæs cannot be held responsible for connectivity problems in these circumstances. NOTE: Whenever BeaconMedæs Envirom bedhead trunking systems are installed extra long probes must be used if humidifiers/jars are to be connected directly to the devices. SOT FLOWMETER & VACUUM SUCTION Oxygen regulators shall be supplied to ISO 10524-1:2006, EN 7381:1997 and constructed from chrome-plated brass (high pressure stage), chrome-plated aluminium, stainless steel, polycarbonate, NBR, sintered bronze (inlet filter) and TPE (gauge cover). Sterilising Specification SafetyTrap ® and DISS adapter: Steam sterilization in gravity autoclave: - SafetyTrap® PC: 121ºC, 1,3kg/cm2, for 25 minutes* - SafetyTrap® PSU: 134ºC, 2,4kg/cm2, for 15 minutes* - DISS adapter: 134 ºC, 2,4 kg/cm2, for 15 minutes * * Drying time: 30 min SafetyTrap® PC can be sterilized up to 40 times and SafetyTrap® PSU can be sterilized up to 100 times. The DISS adapter can be sterilized an unlimited number of times. Before each use, verify that the device is not damaged. Never put the product in direct contact with the autoclave chamber (it could be damaged). It is recommended to use a basket. Humidifier: Sterilisation should be conducted in an autoclave on a 25 min cycle at 121 ºC, 1,3 kPa (max. 40 times). Before sterilisation remove the tube and diffuser and consequently disposed. Flowmeter’s and vacuum suction units shall be supplied with gas specific probes and only attach to the corresponding medical gas terminal unit. Gas specific components shall be specifically sized to ensure that a correct gas specific assembly is achieved so that in normal course of dismantling for repair or maintenance, parts from other gases cannot inadvertently be used. Flowmeter shall be manufactured to EN 13220:1999 and ISO 15002:2008 and constructed from chromium-plated brass body, inner and external tube in polycarbonate and stainless steel ball. Other pieces shall be in brass, polyamide and NBR. Latex free. High precision dial flowmeter’s shall be aluminium body, polycarbonate dial and chromium-plated brass DISS outlet. Other parts shall be made of stainless steel, NBR, silicone and polyamide. Vacuum suction devices (high and low) shall be ABS and polycarbonate body and a polycarbonate vacuum gauge cover. O-rings shall be NBR and silicone, pneumatic mechanism in POM and TPE. inlet thread female WGAS ¼” shall be chrome-plated brass. High precision continuous/intermittent suction devices shall be manufactured in aluminum (body), polycarbonate (scale), polysulfone (water trap), with remaining internal pieces made out of silicone, viton, POM and TPE. Water trap and bacterial filter housing shall be in polycarbonate as standard or polysulphone on request. Atlas Copco Ltd. trading as Atlas Copco Medical Unit 18 Nuffield Way, Abingdon, Oxfordshire, UK OX14 1RL www.beaconmedaes.com The flowmeter and vacuum suction unit shall have a two-year warranty, subject to the recommended minimum routine maintenance operations being carried out by correctly competent persons. The standard range of BeaconMedæs SOT, flow meter and Vacuum Regulator Unit are ‘CE’ marked under the Medical Devices Directive 93/42/EEC with approval from notified body no. 0051. Under this directive, the specified products are classified as Clas

 Open the catalog to page 1
Flow Meters and Vacuum Regulators HTM/ISO Specification Sheet-2

Technical Specification and Ordering:lowmeter Product High Precision Dial Flowmeter * 0.50 l/min flowmeter is indicated for CPAP Atlas Copco Ltd. trading as Atlas Copco Medical Unit 18 Nuffield Way, Abingdon, Oxfordshire, UK OX14 1RL www.beaconmedaes.com

 Open the catalog to page 2
Flow Meters and Vacuum Regulators HTM/ISO Specification Sheet-3

Vacuum Regulating Units * Powered from vacuum source Atlas Copco Ltd. trading as Atlas Copco Medical Unit 18 Nuffield Way, Abingdon, Oxfordshire, UK OX14 1RL www.beaconmedaes.com

 Open the catalog to page 3
Flow Meters and Vacuum Regulators HTM/ISO Specification Sheet-4

Accessories Product Atlas Copco Ltd. trading as Atlas Copco Medical Unit 18 Nuffield Way, Abingdon, Oxfordshire, UK OX14 1RL www.beaconmedaes.com

 Open the catalog to page 4
Flow Meters and Vacuum Regulators HTM/ISO Specification Sheet-5

Oxygen Regulators Product * Other gas types available include N20, Air and CO2 Atlas Copco Ltd. trading as Atlas Copco Medical Unit 18 Nuffield Way, Abingdon, Oxfordshire, UK OX14 1RL www.beaconmedaes.com

 Open the catalog to page 5
Flow Meters and Vacuum Regulators HTM/ISO Specification Sheet-6

Flowmeter Selector Flow selector she PA 66 ♦ Chromum plated brass Selector body Chromum plated brass Hose -tube racorn selector control knob Chromium plated brass plated brass Atlas Copco Ltd. trading as Atlas Copco Medical Unit 18 Nuffield Way, Abingdon, Oxfordshire, UK OX14 1RL www.beaconmedaes.com

 Open the catalog to page 6
Flow Meters and Vacuum Regulators HTM/ISO Specification Sheet-7

In an effort to continuously improve our products, the right is reserved to change the specification of the items described herein at any time. Please contact us for further information and up to date specifications. High Vacuum Suction Venturi Suction Atlas Copco Ltd. trading as Atlas Copco Medical Unit 18 Nuffield Way, Abingdon, Oxfordshire, UK OX14 1RL www.beaconmedaes.com

 Open the catalog to page 7

All BeaconMedaes catalogs and technical brochures

  1. Central alarm

    4  Pages

  2. Magnis MSV

    2  Pages

  3. mVAC

    12  Pages

Archived catalogs

  1. Local alarm

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.