Suction & Oxygen Therapy - 1

Continuous Suction Regulators Built for easy use BeaconMedæs regulators are designed to be easy to see and easy to operate. The bright gauge face allows checking the vacuum level from across the room and the big, convenient knobs allow easy adjustment. BeaconMedæs regulators are especially compact to t even in tight arrangements where other regulators are squeezed out by other equipment. Built to stay on duty, not on the bench Illustrated: ustrated: US Standard S Tri-mode with i-mode Tubing nipple ubing A regulator built to last Built tough BeaconMedæs suction regulators are constructed using a cast metal backplate with the gauge fully encased in the protective housing. That means the BeaconMedæs regulator can withstand stresses which would normally crack an all plastic regulator and will continue to operate when other regulators would have to be replaced. BeaconMedaes regulators are fully modular (only six modules in a continuous regulator), which means if they do need service, the work can quickly be done with ordinary tools and ordinary skills. No need for the regulator to sit unusable, waiting for a complex repair operation. Warranty BeaconMedæs Continuous Suction Regulators are warranted against defects in parts or workmanship for 3 years from the date of shipment. At it’s discretion BeaconMedæs will replace or repair the defective unit. This warranty excludes regulators which are damaged or abused through incorrect use or negligence. Extended warranties and service agreements are available through BeaconMedæs factory service. Please inquire through your BeaconMedæs representative. Continuous Regulator Models Gauge Range 0-300 mmHg and “MAX VACUUM” Standard Tri-Mode LINE - OFF - REG(ulated) Tri-Mode LINE - OFF - REG(ulated) All regulator models can be equipped with inlet and outlet ttings in all popular styles. See table on reverse. 0-760 mmHg and “MAX VACUUM” High Flow Technical Specications Weight 1.1 lbs (0.5 kG) Gage Accuracy ± 1% FS Digital ± 5% FS of maximum Analog REG(ulated) mode Maximum Vacuum 396 mmHg for Standard Regulators REG(ulated) mode Maximum Vacuum 760 mmHg for High Flow Surgical Regulators 1 Dimensions: 3.7” (9.4 cm) deep; 2.8” (7.1 cm) wide; 5.2” (13.2 cm) high 1 Actual obtainable vacuum may be limited by vacuum pump, medical vacuum terminal, and altitude. Specications subject to change without notice

Open the catalog to page 1
Suction & Oxygen Therapy - 2

Ordering Data BeaconMedæs regulators are available with all popular inlet and outlet combinations. Outlet Fittings (back of regulator) 1/8 NPTF (tting by others) Tubing Nipple Inlet Fittings (bottom of regulator) DISS Standard 2205601507 High Flow Surgical 2205601563 Standard 2205601508 High Flow Surgical 2205601564 Standard 2205601509 High Flow Surgical 2205601565 Standard 2205601510 High Flow Surgical 2205601566 Standard 2205601511 High Flow Surgical 2205601567 Standard 2205601512 High Flow Surgical 2205601568 Standard 2205601513 High Flow Surgical 2205601569 Tubing Nipple Standard...

Open the catalog to page 2

All BeaconMedaes catalogs and technical brochures

  1. Local alarm

    4 Pages

  2. Magnis MSV

    2 Pages

  3. mVAC

    12 Pages

Archived catalogs