Breast Localization Wire & Guide Needle Basic information Localization wire (wire) and marker clip (clip) are implantable positioning devices that can be used to locate primary breast lesions and axillary lymph metastases through image-guided percutaneous puncture. Clinical studies It is an important tool for accurate functional breast surgery [1-4]. Benefits By using breast tissue positioning guide wire and positioning marker clip to accurately locate breast and axillary lesions, the target lesions can be completely removed, and the damage to surrounding normal tissues can be reduced on the basis of ensuring tumor safety [1 -4], Designed to lock securely while being able to reposition after placement [1] Kapoor MM, Patel MM, Scoggins ME. The Wire and Beyond: Recent Advances in Breast Imaging Preoperative Needle Localization [J] . Radiographics, 2019, 39(7): 1886-1906. [2] Chen WZ, Jiang JX, Sun SS, et al. Clinical practice guidelines for visualized percutaneous breast tissue clips: Chinese Society of Breast Surgery (CSBrS) practice guideline 2021 [J] . Chin Med J (Engl), 2021,134(15): 1768-1770. [3] Breast Surgery Group, Surgical Society of Chinese Medical Association. Expert consensus and technical operation Opinion on clinical application of visual percutaneous breast tissue positioning marker clip (2020) [J], Chinese Journal of Surgery, 2020, 58(3): 165-169. [4] Chen Wuzhen, Chen Zhiye, Yu Xiuyan, et al. Clinical application of visual percutaneous breast focal location clamp [J], Chinese Journal of Practical Surgery, 2018,38(11): 1248-1254. (in Chinese)

 Open the catalog to page 1
Breast localization needle BL series-2

The back of the positioning guide wire pre-installed in the guide needle has two release indication markers to indicate the position of the wire tip relative to the needle. The first release indicator mark for the localization wire is located outside the guide needle handle, indicating that the "Q/double J" shape of the localization wire is completely inside the piercing needle. As the positioning localization wire gradually enters the guide needle, the first release indicator mark enters the guide needle handle, and the shape of the localization guide wire begins to unfold. The localization...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.