Catalog excerpts

Cystatin C is a relatively small protein that is produced throughout the body by all cells that contain a nucleus and is found in a variety of body fluids, including the blood. It is produced, filtered from the blood by the kidneys, and broken down at a constant rate. This test measures the amount of cystatin C in blood to help evaluate kidney function. Cystatin C is filtered out of the blood by the glomeruli, clusters of tiny blood vessels in the kidneys that allow water, dissolved substances, and wastes to pass through their walls while retaining blood cells and larger proteins. What passes through the walls of the glomeruli forms a filtrate fluid. From this fluid, the kidneys reabsorb cystatin C, glucose, and other substances. The remaining fluid and wastes are carried to the bladder and excreted as urine. The reabsorbed cystatin C is then broken down and is not returned to the blood. Test cassette Extraction buffer
Open the catalog to page 1
Specification Sample type Sample vol. Assay time Working range Performance Storage Shelf Life Ordering Information Item Cystatin C (Cys-C) Test Kit Packing 25 tests/box; 20 boxes/ctn Beijing O&D Biotech Co., Ltd. Web: www.odbio.com Contact: Grace Zhang, zhangjh@odbio.com; Jason Du, dujf@odbio.com ADD: West, Floor 4, Building 1, No.1, Shunqiang Road, Renhe Town, Shunyi District, Beijing, C
Open the catalog to page 2
Compatible Instruments Specifications Item KS-001 Dry Fluorescent Immunoassay Analyzer KS-002 Dry Fluorescent Immunoassay Analyzer Catalogue Number Testing Modes Auto-test/Queuing/Instant test Automatic testing Testing Speed 120 T/h under the Queuing Mode 8" LCD screen. The instrument can be connected to a monitor by VGA interface. Built-in thermal printer Built-in thermal printer
Open the catalog to page 3
Technical Strength 1. Semi-Liquid Phase Reaction Half of the immune reaction is done in the liquid phase, which effectively improves the sensitivity and accuracy of the product. In the sample, the antigen binds more fully to the fluorescently labeled antibody. The release of fluorescent microspheres on the NC membrane is more uniform. Test results of whole blood samples have better repeatability. 2. Red Nanofluorescent Technology a. Comparing with ordinary fluorescein 1) FITC (fluorescein isothiocyanate) and other fluorescent substances are light sensitive and thus easily quenched. Their...
Open the catalog to page 4
O&D Biotech Fluorescent Immunoassay Parameters Sample Test Item Working Range Shelf Life NT-proBNP Cardiac
Open the catalog to page 5All Beijing O&D Biotech Co. catalogs and technical brochures
-
Company Profile-O&D Biotech
42 Pages
-
ACT99 Plus 0055HC
2 Pages
-
AMH Test Kit (FIA) 00025C
5 Pages
-
NGAL Test Kit (FIA) 00020C
5 Pages
-
PCT Test Kit (FIA) 00005C
5 Pages
-
HbA1C Test Kit (FIA) 00021C
5 Pages
-
H-FABP Test Kit (FIA) 00008C
5 Pages
-
cTnI Test Kit (FIA) 00001C
5 Pages
-
CK-MB Test Kit (FIA) 00003C
5 Pages
-
Myo Test Kit (FIA) 00002C
5 Pages
-
MPO Test Kit (FIA) 00027C
5 Pages
-
CRP Test Kit (FIA) 00006C
5 Pages