1. Catalogs
  2. Beijing O&D Biotech Co., Ltd.
  3. H-FABP Test Kit (FIA) 00008C
video corpo

H-FABP Test Kit (FIA) 00008C
1 /5Pages

H-FABP Test Kit (FIA) 00008C

H-FABP Test Kit (FIA) 00008C
1 /5Pages

Catalog excerpts

H-FABP Test Kit (FIA) 00008C-1

Heart fatty-acid binding protein (H-FABP) is one of the most abundant proteins in cardiomyocytes. Upon acute myocardial infarction (AMI) the blood and urine levels of H-FABP rise rapidly within 1-3 hours, reach their peak values at 6 hours, and return to baseline concentration within 24 hours. Characteristics of H-FABP appear to be similar to those of myoglobin. However, H-FABP concentrations are almost 10-fold higher in the heart than in the skeletal muscle. In contrast, myoglobin concentrations are 2-fold lower in cardiac cells than skeletal cells. Thus, the greater cardiospecificity of H-FABP account for its greater value in diagnostics of AMI. Test cassette Extraction buffer

 Open the catalog to page 1
H-FABP Test Kit (FIA) 00008C-2

Specification Sample type Sample vol. Assay time Working range Performance Storage Shelf Life Ordering Information Item Cat # Heart fatty-acid binding pr 00008C otein (H-FABP) Test Kit Packing 25 tests/box; 20 boxes/ctn Beijing O&D Biotech Co., Ltd. Web: www.odbio.com Contact: Grace Zhang, [email protected]; Jason Du, [email protected] ADD: West, Floor 4, Building 1, No.1, Shunqiang Road, Renhe Town, Shunyi District, Beijing, Chi

 Open the catalog to page 2
H-FABP Test Kit (FIA) 00008C-3

Compatible Instruments Specifications Item KS-001 Dry Fluorescent Immunoassay Analyzer KS-002 Dry Fluorescent Immunoassay Analyzer Catalogue Number Testing Modes Auto-test/Queuing/Instant test Automatic testing Testing Speed 120 T/h under the Queuing Mode 8" LCD screen. The instrument can be connected to a monitor by VGA interface. Built-in thermal printer Built-in thermal printer

 Open the catalog to page 3
H-FABP Test Kit (FIA) 00008C-4

Technical Strength 1. Semi-Liquid Phase Reaction Half of the immune reaction is done in the liquid phase, which effectively improves the sensitivity and accuracy of the product. In the sample, the antigen binds more fully to the fluorescently labeled antibody. The release of fluorescent microspheres on the NC membrane is more uniform. Test results of whole blood samples have better repeatability. 2. Red Nanofluorescent Technology a. Comparing with ordinary fluorescein 1) FITC (fluorescein isothiocyanate) and other fluorescent substances are light sensitive and thus easily quenched. Their fluorescence...

 Open the catalog to page 4
H-FABP Test Kit (FIA) 00008C-5

O&D Biotech Fluorescent Immunoassay Parameters Sample Test Item Working Range Shelf Life NT-proBNP Cardiac

 Open the catalog to page 5