1. Catalogs
  2. Beijing O&D Biotech Co., Ltd.
  3. Insulin (INS) Test Kit (FIA) 00034C
video corpo

Insulin (INS) Test Kit (FIA) 00034C

Insulin (INS) Test Kit (FIA) 00034C

Insulin (INS) Test Kit (FIA) 00034C

Product catalog summary
Overview of Insulin Function: Insulin is a hormone produced in the pancreas's beta cells, crucial for glucose transportation and storage. It regulates blood glucose levels and plays a role in lipid metabolism. The test measures insulin levels in the blood.
Test Specifications: The insulin test kit requires a sample type of whole blood, serum, or plasma with a volume of 75μL. The assay time is 15 minutes, with a working range of 1-300 mIU/L and a performance coefficient of variation (CV) of ≤15%. The storage temperature is between 2-30℃, and the shelf life is 18 months.
Ordering Information: The insulin test kit (Cat # 00034C) is available in packs of 25 tests per box, with 20 boxes per carton. Compatible instruments include KS-001 and KS-002 Dry Fluorescent Immunoassay Analyzers.
Compatible Instruments:
  • KS-001: Single-channel, auto-test/queuing/instant test modes, 120 tests/hour, CV ≤ 10%, 7" LCD touch screen, built-in thermal printer, dimensions 265x212x128 mm, weight 2.5 kg.
  • KS-002: 12-channel, automatic testing, up to 120 tests/hour, CV ≤ 10%, 8" LCD screen with VGA interface, built-in thermal printer, dimensions 490x328x336 mm, weight 16 kg.
Technical Strengths:
  • Semi-Liquid Phase Reaction: Enhances sensitivity and accuracy by allowing more complete antigen-antibody binding and uniform release of fluorescent microspheres.
  • Red Nanofluorescent Microsphere Technology: Offers stability and resistance to light quenching, maintaining fluorescence efficiency and avoiding interference from endogenous substances.
O&D Biotech Fluorescent Immunoassay Parameters: The document lists various test items, sample types, volumes, assay times, working ranges, clinical references, shelf lives, and certifications (CE, NMPA) for cardiac, diabetes, hormone, infection, and other categories.
See more

Catalog excerpts

Insulin (INS) Test Kit (FIA) 00034C-1

Insulin is a hormone that is produced and stored in the beta cells of the pancreas. It is secreted in response to elevated blood glucose following a meal and is vital for the transportation and storage of glucose, the body's main source of energy. Insulin helps transport glucose from the blood to within cells, thus helping regulate blood glucose levels, and has a role in lipid metabolism. This test measures the amount of insulin in the blood. Insulin and glucose blood levels must be in balance. After a meal, carbohydrates usually are broken down into glucose and other simple sugars. These are absorbed into the blood, causing the blood glucose level to rise, which in turn stimulates the pancreas to release insulin into the blood. As glucose moves into cells, the level in the blood decreases and release of insulin by the pancreas decreases. Test cassette Extraction buffer

 Open the catalog to page 1
Insulin (INS) Test Kit (FIA) 00034C-2

Specification Sample type Sample vol. Assay time Working range Performance Storage Shelf Life Ordering Information Item Insulin (INS) Test Kit Packing 25 tests/box; 20 boxes/ctn Beijing O&D Biotech Co., Ltd. Web: www.odbio.com Contact: Grace Zhang, [email protected]; Jason Du, [email protected] ADD: West, Floor 4, Building 1, No.1, Shunqiang Road, Renhe Town, Shunyi District, Beijing, Chi

 Open the catalog to page 2
Insulin (INS) Test Kit (FIA) 00034C-3

Compatible Instruments Specifications Item KS-001 Dry Fluorescent Immunoassay Analyzer KS-002 Dry Fluorescent Immunoassay Analyzer Catalogue Number Testing Modes Auto-test/Queuing/Instant test Automatic testing Testing Speed 120 T/h under the Queuing Mode 8" LCD screen. The instrument can be connected to a monitor by VGA interface. Built-in thermal printer Built-in thermal printer

 Open the catalog to page 3
Insulin (INS) Test Kit (FIA) 00034C-4

Technical Strength 1. Semi-Liquid Phase Reaction Half of the immune reaction is done in the liquid phase, which effectively improves the sensitivity and accuracy of the product. In the sample, the antigen binds more fully to the fluorescently labeled antibody. The release of fluorescent microspheres on the NC membrane is more uniform. Test results of whole blood samples have better repeatability. 2. Red Nanofluorescent Technology a. Comparing with ordinary fluorescein 1) FITC (fluorescein isothiocyanate) and other fluorescent substances are light sensitive and thus easily quenched. Their fluorescence...

 Open the catalog to page 4
Insulin (INS) Test Kit (FIA) 00034C-5

O&D Biotech Fluorescent Immunoassay Parameters Sample Test Item Working Range Shelf Life NT-proBNP Cardiac

 Open the catalog to page 5

All Beijing O&D Biotech Co., Ltd. catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.