Pepsinogen I/Pepsinogen Ⅱ (PGI/PGII) Test Kit (FIA) 00032C
5Pages

{{requestButtons}}

Catalog excerpts

Pepsinogen I/Pepsinogen Ⅱ (PGI/PGII) Test Kit (FIA) 00032C - 1

Pepsinogen I and II, the precursors of pepsin, are produced by the gastric mucosa and released into the gastric lumen and peripheral circulation (Samloff and Liebman, 1973). Severe inflammation of gastric mucosa and its progression toward atrophic gastritis (AG) is correlated with a change in serum biomarkers pepsinogen I and II. It has been previously reported that pepsinogen II is a good marker for the diagnosis of any type of gastritis as it can differentiate between subjects with gastritis from those with normal mucosa. The progression of gastritis to acute and pangastritis is associated with a continual increase in serum pepsinogen II levels, whereas the levels of pepsinogen I in the early stage of acute gastritis remain unchanged and in the normal range. Test cassette Extraction buffer

Open the catalog to page 1
Pepsinogen I/Pepsinogen Ⅱ (PGI/PGII) Test Kit (FIA) 00032C - 2

Specification Sample type Sample vol. Assay time Working range Performance Storage Shelf Life Ordering Information Item Pepsinogen I/Pepsinogen Ⅱ (PGI/PGII) Test Kit Packing 25 tests/box; 20 boxes/ctn Beijing O&D Biotech Co., Ltd. Web: www.odbio.com Contact: Grace Zhang, zhangjh@odbio.com; Jason Du, dujf@odbio.com ADD: West, Floor 4, Building 1, No.1, Shunqiang Road, Renhe Town, Shunyi District, Beijing, C

Open the catalog to page 2
Pepsinogen I/Pepsinogen Ⅱ (PGI/PGII) Test Kit (FIA) 00032C - 3

Compatible Instruments Specifications Item KS-001 Dry Fluorescent Immunoassay Analyzer KS-002 Dry Fluorescent Immunoassay Analyzer Catalogue Number Testing Modes Auto-test/Queuing/Instant test Automatic testing Testing Speed 120 T/h under the Queuing Mode 8" LCD screen. The instrument can be connected to a monitor by VGA interface. Built-in thermal printer Built-in thermal printer

Open the catalog to page 3
Pepsinogen I/Pepsinogen Ⅱ (PGI/PGII) Test Kit (FIA) 00032C - 4

Technical Strength 1. Semi-Liquid Phase Reaction Half of the immune reaction is done in the liquid phase, which effectively improves the sensitivity and accuracy of the product. In the sample, the antigen binds more fully to the fluorescently labeled antibody. The release of fluorescent microspheres on the NC membrane is more uniform. Test results of whole blood samples have better repeatability. 2. Red Nanofluorescent Technology a. Comparing with ordinary fluorescein 1) FITC (fluorescein isothiocyanate) and other fluorescent substances are light sensitive and thus easily quenched. Their...

Open the catalog to page 4
Pepsinogen I/Pepsinogen Ⅱ (PGI/PGII) Test Kit (FIA) 00032C - 5

O&D Biotech Fluorescent Immunoassay Parameters Sample Test Item Working Range Shelf Life NT-proBNP Cardiac

Open the catalog to page 5