HIGH Power 40W Fractional Mode CW Mode Ultra Mode
Open the catalog to page 1The CO2 laser beam heats and vaporizes the skin tissue , instantly removing the superficial layers of the skin. Each fractional micro spot creates a thermal zone. Intact cells around the treated area help the healing process . This process induces cell regeneration. The contraction is immediate and the structural improvement of the skin you start to see about one week after the procedure . Delivers multiple arrays of 10600nm laser beam to the skin by fractional scanning, forming a burning zone of an array of laser points on the epidermis. Every laser point, consisting of single or severla highenergy...
Open the catalog to page 2SCANNER HAND PIECE 120 µm Spot l Scars Deep Wrinkles Tightening Large Pores Skin Texture Luminosity Skin Toning Texture Luminosity Zoom 0.2 a 10mm Handpiece Micro F50 Handpiece (optional spot 500 µm) Micro F100 Handpiece (optional spot 1000 µ
Open the catalog to page 3More refined More efficient long time 7-10 years More uniform l Less recovery time l Long time to use ( 7-10 years) l use air cooling,no need maintance l Energy is even in every dot
Open the catalog to page 4Healing zone selecting matches to each patient’s needs
Open the catalog to page 6Vaginal Heads & Digital Endoscope Vaginal Heads Digital Endoscope
Open the catalog to page 7What is Fractional CO2 Laser used to treat? Fractional Laser can be used for the following conditions: Fine lines and wrinkles Skin Rejuvenation Stretch marks Acne scars • Photoaging Skin Surgical scars
Open the catalog to page 8Before & After
Open the catalog to page 9Specifications Laser source: Mtal RF co2 Laser Generator Laser Type: Output Power: Focal length of working head: Indication Beam: Transmission System: Smoke Exhausting System: Cooling System: Environmental temperature: Relative Humidity: Power Supply: Working mode Continous: Power 1~40W step adjustable each 1 W Power 1~40W step adjustable each 1 Interval time: Ultra pulse: Power 1~40W step adjustable each 1 Modulated frequency of 1000 Hz Pulse Duration: Scanning mode Scan mode: Ellipse, Rectangular, Triangular, Line, Square, hexagon, round Repeat Delay: Micro Pulse Energy: Treatment Level: Estimated...
Open the catalog to page 10Standard with
Open the catalog to page 116 Pages
17 Pages
14 Pages
13 Pages
16 Pages
17 Pages
9 Pages
11 Pages
18 Pages
16 Pages
8 Pages
11 Pages
14 Pages
13 Pages
12 Pages
11 Pages
13 Pages
15 Pages
18 Pages
11 Pages
15 Pages
1 Page
13 Pages
20 Pages
14 Pages
6 Pages
15 Pages
13 Pages
12 Pages
15 Pages
18 Pages
16 Pages
15 Pages
17 Pages