Vacuum microneedle RF machine
1 / 13Pages

Catalog excerpts

Vacuum microneedle RF machine - 1

PINXEL-VS The Newest Generation- In Advanced Microneedling

Open the catalog to page 1
Vacuum microneedle RF machine - 2

APPLICATION One device. All skin types. All skin esurfacing. Face Fine Lines Deep Wrinkles Acne Scars Skin Reconstruction Appearance of Large Pores Body Stretch Marks Scars from injury or surgery Loose & Sagging Skin

Open the catalog to page 2
Vacuum microneedle RF machine - 3

WORKING MECHANISM Collagen induction therapy is one of the safest skin resurfacing treatment available. Also known as skin needling. It involves the use of a single use needle gently penetrating into the skin needling stimulates the release of growth factors that build up natural collagen and elastin in the area that’s being treated. This is an excellent method of collagen insuction as the epidermis and melanocytes in the deep layer of the skin are not damaged so there is no possibility of pose inflammatory hyper pigmentation. Unlike lasers or dermabrasion, RF powered microneedling can be...

Open the catalog to page 3
Vacuum microneedle RF machine - 4

ADVANTAGE-VACUUM Pinxel-VS update RF microneedling with vacuum, push the topical deeper with one kind dual air chamber design, air is captured through enhanced tissue engagement, microneedles creat channels and RF energy is delivered, as needles retract, air is released towards the skin, driving topicals deeper into the dermis, resulting in enhanced topical penetration up to 67% with the M and F Type needles. Pinxel-VS takes RF microneedling to new levels. The versatility this system provides allows you to customize treatments based on your patients’ specific needs – all skin types,...

Open the catalog to page 4
Vacuum microneedle RF machine - 5

Metal Frame Stepping Motor Driving Modular Component Button Switch Large screen display

Open the catalog to page 5
Vacuum microneedle RF machine - 6

MICRO NEEDLE RF Applicator - MICRO NEEDLE RF (RF) applicator for procedures requiring ablation and resurfacing of the skin. Add vacuum - suction combined probe for better skin contact, especially around eyes and neck areas. Stepping Motor Type Gold Plating Stepping Motor Type, different to existing solenoid type, the needle inserts to the skin smoothly with no shock, and causes no bleeding and no pain after the procedure Safety Needle System Needle Depth Control ⚫ Operate epidermis and dermis layer by controlling the needle depth in unit of 0.2mm. Needle is durable and also have high...

Open the catalog to page 6
Vacuum microneedle RF machine - 7

INSULATED & NON INSULATED In s u l ate d RF Target Area Less painful Treat Dermis only Less redness, easy to recovery Insulated NonInsulated Less result ▘Suitable for person who need go to work everyday -Epidermis & Dermis Painful Treat Dermis and Epidermis More recovery time, easy scab NonInsulated Better result ▘Suitable for person who want good resul

Open the catalog to page 7
Vacuum microneedle RF machine - 8

FRACTIONAL RF Applicator -- FRACTIONAL RF applicator for non-invasive wrinkle reduction, suit for the patients fear of needle, no down time, recovery soon. ▘Eyes ▘Nose Area ▘Face Area

Open the catalog to page 8
Vacuum microneedle RF machine - 9

PINXEL-VS -MONO/BIPOLAR -- Negtive polar (MONO/BI POLAR) Face :Evenly Under Bipolar 50% percent needle is positive and Negtive Handle: Together with MONO polar, energy transfer Deeper the other 50% is negative polar. this make the energy only works on depth of the needle. This mode is more suitable for face treatment. Body: Deeper Under the Mono mode all the needles on the tip is positive polar. The customer need to hold the negative polar in hand during the treatment. The RF energy can go to more deeper to skin than Bipolar ▘NEGATIVE POLE ▘POSITIVE ELECTRODE mode. So it's more suitable for...

Open the catalog to page 9
Vacuum microneedle RF machine - 10

UI INTERFACE 10.4 inch Full-size touch operation , Sliding menus, easy operation. Wording Mode Working/Stop Pressure level Needle deepth Negtive polar (MONO/BI POLAR) Preservation

Open the catalog to page 10
Vacuum microneedle RF machine - 11

W orkin g m o d e Mo d e Co o lin g Tip s I n va sive Tip s No n in va sive Tip s

Open the catalog to page 11
Vacuum microneedle RF machine - 12

Before & After Befo re Stretch Marks -Age 36 Level 5 2.0 mm tip 150 ms 2 pass 3 weeks delay 1 treatment times Scars from injury Acne Pores Level 4 I.0 mm tip 140 ms 2 pass 3 weeks delay 3 treatment times Level 4 1.5 mm tip 120 ms 1 pass 3 weeks delay 1 treatment times

Open the catalog to page 12
Vacuum microneedle RF machine - 13

THANKS www.sanhemedical.com Address: 2rd floor, Building No.7, Maohuagongchang, Nancaizhen, Shunyi District, Beijing Tel: +8618501921559 Email: anny@sanhebeauty.com

Open the catalog to page 13

All Beijing Sanhe Beauty catalogs and technical brochures

  1. DPL-P

    13 Pages

  2. DPL

    6 Pages

  3. SC-2

    15 Pages

  4. SC-4

    13 Pages

  5. SHR950S-2

    13 Pages

  6. SHR950B

    12 Pages

  7. ICOOL-2

    17 Pages

  8. SH650-2

    15 Pages

  9. Magshape

    15 Pages

  10. PINXEL-V

    14 Pages

  11. SP-5

    16 Pages

  12. SP-4

    18 Pages

  13. P808S

    16 Pages

  14. HIDL-808

    16 Pages

  15. 3000W

    17 Pages