1. Catalogs
  2. Beijing Sanhe Beauty
  3. Vertical Fractional CO2 Laser -Vertical co2

Vertical Fractional CO2 Laser -Vertical co2

Vertical Fractional CO2 Laser -Vertical co2
1 / 13 PagesView full catalog

Vertical Fractional CO2 Laser -Vertical co2

Product catalog summary
Overview: The Medical Metal Tube CO2 Fractional Laser Skin Care System is designed for fractional resurfacing, a laser treatment that creates microscopic thermal injury zones to promote rapid skin repair. This system allows for high-energy treatments with minimized risks when used with proper laser-delivery systems.
Machine Components: The system includes protective glasses, a foot switch, scanners, cutting surgery heads, vaginal heads, and a digital endoscope. The scanner has a maximum scanning size of 20x20mm.
Operation Interface: The interface offers various scan modes (CW/Pulse/Ultra pulse) and a green guide light. It allows customization of scan density, size, shape, and depth to match patient needs, with immediate results in skin removal and collagen remodeling.
Specifications: The laser operates at 10.6μm with a power output of 40W. It includes a red diode laser for indication, a 7-articulation joint spring arm for transmission, and built-in air cooling. The system operates within 5°C to 40°C and requires a power supply of ~220V±22V, 50Hz±1Hz.
Working Modes: The system supports continuous, pulse, and ultra pulse modes with adjustable power and pulse duration. It offers various scanning shapes and depths, with a maximum scanning diameter of 20x20mm.
Indications: The laser system is suitable for skin resurfacing, treating pigmented lesions, wrinkles, acne scars, surgical scars, melasma, actinic keratoses, and various vaginal treatments.
Pre-Treatment Notice: Patients should avoid aspirin, high doses of vitamin E, garlic, alcohol, and smoking two weeks before and after treatment. Preliminary examinations may be required, and patients should avoid makeup and wear loose clothing on the day of the procedure.
Operation Procedure: A topical anesthetic is applied 20-30 minutes before treatment. Cold air is used for comfort during the procedure, and a semi-conductor laser is applied post-treatment to enhance results.
Vaginal Treatment Procedure: The digital endoscope is used to assess the condition, followed by laser irradiation with a 360-degree revolution for rejuvenation and whitening.
See more

Catalog excerpts

Vertical Fractional CO2 Laser -Vertical co2-1

Medical Metal tube Co2 fractional laser skin care system

 Open the catalog to page 1
Vertical Fractional CO2 Laser -Vertical co2-2

How does it works? Fractional resurfacing is a new laser treatment modality that creates numerous microscopic thermal injury zones of controlled width, depth, and density that are surrounded by a reservoir of spared epidermal and dermal tissue, allowing for rapid repair of laser-induced thermal injury. This unique modality, if implemented with proper laser-delivery systems, enables high-energy treatments while minimizing risks. protective Glasses (Professional Anti laser radiation) foot switch ( Professional Anti electricity leakag

 Open the catalog to page 2
Vertical Fractional CO2 Laser -Vertical co2-3

Scanners & Cutting Surgery Heads Scanner. Scanning size: Maximum 20*20mm Cutting surgery head

 Open the catalog to page 3
Vertical Fractional CO2 Laser -Vertical co2-4

Vaginal Heads & Digital Endoscope 1 Digital Endoscope Gold plating Reflector: Reflect the Laser Speculum: Broaden the vagina for procedure

 Open the catalog to page 4
Vertical Fractional CO2 Laser -Vertical co2-5

Scan mode fefreu tootmxtch to Activate CW/Pulse/Ultra pulse Mode

 Open the catalog to page 5
Vertical Fractional CO2 Laser -Vertical co2-6

Special designing green Guide light Scan size and shape Healing zone selecting matches to each patient’s needs Leave 95% to 0% intact Scan density Shape: Ellipse, Rectangular, Triangular, Line, Square, hexagon, round Size: single pulse scanning maximum 20*20mm adjustable Scan depth Select target depth (Epidermal or Dermal) Scan Depth:20um-2000um adjustable

 Open the catalog to page 6
Vertical Fractional CO2 Laser -Vertical co2-7

Treatment Benefits Before and Afterbefore treatmentjust after treatmentMatch patient needs to results • Select healing zone volume (Density) • Select volume treated (Spot Size) • Select target depth (Epidermal or Dermal) • Removal damaged skin • Contracture via heat & ablation • Collagen remodeling and Neocollagenesis

 Open the catalog to page 7
Vertical Fractional CO2 Laser -Vertical co2-8

Specifications Laser source: Metal RF tube CO2 Laser Generator Laser Type: Output Power: Focal length of working head: Indication Beam: Transmission System: Smoke Exhausting System: Cooling System: Environmental temperature: Relative Humidity: Power Supply: Dimension: Weight: Working Mode Continous: Pulse: Interval time: Ultra pulse: Pulse Duration: Power 1~40W step adjustable each 1 W Power 1~40W step adjustable each 1 1~999ms Power 1~40W step adjustable each 1 Modulated frequency of 1000 Hz 90-

 Open the catalog to page 8
Vertical Fractional CO2 Laser -Vertical co2-10

Skin resurfacing (to improve texture) Pigmented lesions: Age spots / brown spots / sun spots Wrinkles around the eyes Acne scars Surgical scars Melasma (mask of pregnancy) Actinic Keratoses Stress Urinary Incontinence Relaxed Vagina Labium Whitening Dyspareunia Colpoxerosis Sexual satisfaction

 Open the catalog to page 10
Vertical Fractional CO2 Laser -Vertical co2-11

Notice Before Treatment The patient should not take any medications containing aspirin (acetyl salicylic acid), high doses of vitamin E, eating garlic, consuming alcohol and smoking at least 2 weeks before and after the treatment . The surgeon will decide whether preliminary examinations are necessary, such as blood tests, an electrocardiogram, or x-rays of the lungs. If this is the case, these tests should be performed 2 weeks before the surgery. It is best not to wear any makeup when the client comes in for the operation. Wear loose clothing that doesn't need to be pulled over head; the client...

 Open the catalog to page 11
Vertical Fractional CO2 Laser -Vertical co2-12

Operation Procedure About 20-30 minutes prior to treatment, apply a topical anesthetic to the treatment area. Right before treatment beginning, wash off the anesthetic and apply a thin layer of the tracking gel. During treatment, apply cold air for patient comfort. After treatment, use our semi-conductor laser (physiotherapy laser) to enhance the patient's treatment experience and accelerate the benefits of treatment.

 Open the catalog to page 12
Vertical Fractional CO2 Laser -Vertical co2-13

Vaginal Treatment procedure Use the digital endoscope to detect the condition of privates. Under the WIZ Scan Mode, insert the WIZ handpiece,Laser irradiation with 360-degree revolution ,irradiating the laser Pulling out the handpiece by checking the scales on guide tip. Under the RF Scan Mode, put the Laser Irradiation on Target area , Rejuvenation and whitening.

 Open the catalog to page 13

All Beijing Sanhe Beauty catalogs and technical brochures

  1. V-shaping

    17  Pages

  2. 360 Portable

    11  Pages

  3. Magshape 005

    6  Pages

  4. Magshape 004

    13  Pages

  5. HIDL-1800

    13  Pages

  6. HIDL-808

    16  Pages

  7. SP-3 2000PS

    16  Pages

  8. Patrix

    9  Pages

  9. PINXEL-V

    14  Pages

  10. ICOOL-3

    17  Pages

  11. 8D HIFU

    18  Pages

  12. Rollashape

    14  Pages

  13. Indeeplus-S

    14  Pages

  14. P808S

    16  Pages

  15. DPL Vertical

    6  Pages

  16. DPL-V

    14  Pages

  17. Portable DPL-P

    13  Pages

  18. SHR950B

    12  Pages

  19. SHR950S-2

    13  Pages

  20. Magshape

    15  Pages

  21. SP-4 2000PS

    18  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.