1. Catalogs
  2. Beijing Sincoheren
  3. ND YAG laser MonaLiza 2

ND YAG laser MonaLiza 2

ND YAG laser MonaLiza 2

ND YAG laser MonaLiza 2

Product catalog summary
Introduction
ExQ-Laser™ is a newly released Q-Switched Nd:YAG laser therapy system designed for optimal clinical treatment. It features dual-wavelength switching (1064nm & 532nm), a pulse width as short as 5ns, and energy output up to 1000mJ. The system includes a real-time energy monitor, adjustable handpiece, and water filtration system to ensure safety and efficiency. It has received CFDA and Medical CE certifications and holds multiple global patents.

Principle of Treatment
The treatment principle is based on selective photothermolysis, targeting melanin as the chromophore. The laser's high peak power and nanoseconds-level pulse width allow it to blast pigment granules without damaging surrounding tissues. These granules are then excreted through the circulatory system.

Clinical Indications
- 1064nm: Nevus of Ota, black and blue tattoos
- 532nm: Freckles, café-au-lait spots, red tattoos
Advanced tattoo removal targets dark ink with 1064nm and red ink with 532nm.

Prominent Advantages
The system uses a two-stage Nd:YAG laser with electro-optic Q-Switched technology for higher energy output. It features a cavity-optimized design for a 5ns pulse width and doubled output power density. The integrated energy monitor ensures treatment effectiveness and safety. The adjustable handpiece allows spot size settings from 2 to 10mm, with energy changing synchronously.

Clinical Cases
- Nevus of Ota: 1064nm, 4mm spot size, 4.0J/cm² fluence, 3Hz frequency
- Tattoo removal: 1064nm, 4mm spot size, 4.0J/cm² fluence, 2Hz frequency
- Freckles removal: 532nm, 2mm spot size, 1.5J/cm² fluence, 2Hz frequency
- Café-au-lait spots: 532nm, 2mm spot size, 1.5J/cm² fluence, 2Hz frequency

Technical Parameters
- Laser type: Q-Switched Nd:YAG
- Wavelength: 1064nm, 532nm
- Pulse width: 5ns
- Pulse energy: Up to 1000mJ
- Frequency: 5Hz
- Spot size: 2-10mm adjustable
- Fluence: 0.6-32J/cm²
- Electrical requirements: 110-240VAC 50-60Hz 1200VA
- Dimension: 351mm x 925mm x 775mm
- Net weight: 80Kg

Contact Information
Beijing Sincoheren Science and Technology Development Co., Ltd., AUSMED INTERNATIONAL PTY LTD, Mini Medizin GmbH.
See more

Catalog excerpts

ND YAG laser MonaLiza 2-1

Q-Switched Nd:YAG Laser Therapy Systems

 Open the catalog to page 1
ND YAG laser MonaLiza 2-2

Introduction ExQ-Laser™ is newly released Q-Switched Nd:YAG laser therapy system. The system has an optimal clinical treatment effect with following parameter designs: dual-wavelength switching of 1064nm & 532nm, pulse width short to 5ns and Energy output up to 1000mJ. ExQ-Laser™ integrated with real-time energy monitor, energy auto-changing by adjustable handpiece, water filtration system, sufficiently guarantee the safety and efficiency during using. New UI designs focuse on user experience, make the operation simpler and more convenient. ExQ-Laser™ is safety and reliable with excellent performance,...

 Open the catalog to page 2
ND YAG laser MonaLiza 2-3

Correlation Principle of Treatment Treatment principle for pigmented dermatosis of Q-Switched Nd:YAG Laser Therapy system lies in selective photothermolysis with melanin as the chromophore. Q-Switched Nd:YAG has higher Peak power and nanoseconds-level pulse width. Melanin in melanophore and cuticle formed cells have a short hot relaxation time. It could immediately make small selectively energy absorbed granules (tattoo pigment and melanin) blast without injuring surrounded normal tissues. The blasted pigment granules will be excreted from body through circulatory system. 2.Melanin granules’...

 Open the catalog to page 3
ND YAG laser MonaLiza 2-4

Prominent Advantages Two stages Nd:YAG laser system with electro-optic Q-Switched technology, which output higher energy. The designs adopt cavity optimized schedule, make the pulse width as short as 5ns, get doubled output power density under the same energy. Integrated laser energy monitor system inside, set warning signal when energy deviation over threshold, all to ensure treatment effectiveness and safety. Optical splitter Laser Control Circuit Laser output Energy monitor Laser beam Electrical signal Seven joints optical articulated arm with adjustable handpiece, spots size setting from...

 Open the catalog to page 4
ND YAG laser MonaLiza 2-5

Clinical Cases Tattoo removal Freckles removal café-au-lait spots treatment Statement The technical parameters above are based on a large numbers of clinical practices. It is suggested that the surgeons adopt proper treatment parameters in acco

 Open the catalog to page 5
ND YAG laser MonaLiza 2-6

Technical Parameters Laser type Q-Switched Nd:YAG High energy Q-Switched Nd:YAG Pulse width Pulse energy Pulse energy Range Spot size Aiming beam Electrical requirements Contacts Beijing Sincoheren Science and Technology Development Co., Ltd. Address: Room 305, No.43, Xizhimen Nor th Street, Haidian District,100044 Beijing,China Facility Address: E zone, 3rd floor, 12 plant, No. 2, Kechuang East 5 Street, TongZhou District, Beijing 101111, China Tel: 010-57734969 After-sale Ser vice: 010-82295490 Website:www. sincoheren.com Mini Medizin GmbH Add: Lange Str. 54b, 44579 Castrop-Rauxel,Germany Tel:...

 Open the catalog to page 6
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.