LST - 12 Pages

Add to MyMedicalExpo favorites
LST

Catalog excerpts

Professional Laboratory Sterilization – Safe, Fast and Reliable Steam sterilizers for research facilities, universities and biocontainment facilities

 Open the catalog to page 1

Safe, reliable sterilization in laboratories and research facilities In research institutes, universities and biosafety laboratories people work with highly sensitive laboratory materials requiring extremely responsible handling. Safety and reliability are vital factors in laboratory reprocessing. Belimed is familiar with the demands running a laboratory poses and has been providing state-of-the-art solutions used in laboratories, pharmaceutical companies, biotech companies, universities and hospitals for already over 40 years. Protecting people and the environment Reliable partner There...

 Open the catalog to page 2

State-of-the-art sterilization – the right solution for every requirement Belimed steam sterilizers are particularly suitable for use in laboratories and research, such as in developing active pharmaceutical ingredients, in vaccine research, genetic research, microbiology and in animal care facilities for sterilizing solid and porous materials, liquids and also for deactivating laboratory waste. Maximum exibility Safety about all Our strength is exibility. Sterilization processes, machine The application eld of our laboratory sterilizers meets all capacity and the quality of performance...

 Open the catalog to page 3

Designed for ease of use and ease of maintenance Easy operation Cycle documentation with integrated printer Belimed laboratory sterilizer’s modern graphic user The temperature and pressure prole are continuously interface featuring a touch screen, is simple, self-explana- recorded during sterilization in order to document the tory and well laid out. The modern touch screen technol- sterilization process. Using the integrated printer you can ogy meets all the criteria for maximum user comfort. The directly print out cycle data on the system. various program parameters are easy to modify and...

 Open the catalog to page 4

The precision sealing frame made of solid stainless steel ensures maximum operational reliability. Operational cost-effectiveness, best quality Cost-controlling is of paramount importance for your facilities' success. The Belimed laboratory sterilizers feature a variety of cost-efcient innovations. Optimized process engineering and sophisticated processes ensure efcient and economical operation. Shorter cycle times Safe, reliable and durable The active re-cooling process guarantees short program The laboratory sterilizers are designed to withstand heavy times in the sterilization of...

 Open the catalog to page 5

Sterilization in animal care facilities Belimed ensures the safe and economic reprocessing of animal care equipment. The laboratory sterilizers meet the high hygienic standards of animal care facilities, thus guaranteeing that a specic application area is properly supplied with ingoing sterilized goods or that potentially infectious or genetically modied outgoing material is reliably decontaminated. High safety in cage reprocessing Easy to clean Various standard programs and a broad range of optional The chamber bottom, particle lters and strainers are easy processes provide particularly...

 Open the catalog to page 6

Unique features – designed for BSL 3 and BSL 4 facilities Various biosafety laboratories need autoclaves for sterilization and decontamination. The pathogenic nature of the waste material from such laboratories coupled with the use of the autoclave as a barrier between the facility and the outside world places special requirements on the autoclave design and processes used that standard autoclaves cannot fulll. Belimed offers a wide range of design options referring to individual product specications. Exhaust air and condensation treatment State-of-the-art safety features One or two...

 Open the catalog to page 7

The most compact in its class: the LST-V steam sterilizer Space-saving and easy to operate: the LST-V sterilizer provides optimum conditions for professional laboratory and biotechnology applications. The device provides high performance, is compact and economical. It sets standards in terms of innovation, versatility and small footprint. Operating location Core features The LST-V sterilizer comes optionally with one or two • Excellent useable space to required space ratio (e.g. vertical doors. Featuring differing chamber sizes from 300 only 1 m2 footprint and 2 m high at a chamber size of...

 Open the catalog to page 8

Sterilization of bulky goods with the LST-H steam sterilizer Featuring different chamber sizes, loading heights, loading types and oor-level drivable variants, the LST-H steam sterilizer with horizontally sliding doors is suitable everywhere where large volume solid and porous goods, liquids and waste need to be sterilized or decontaminated. Operating location The LST-H sterilizer is suitable for sterilizing voluminous User-friendly design solid and porous goods, liquids and waste. The oor-level The LST-H sterilizer has a loading height of 320 or loading version also enables the inward and...

 Open the catalog to page 9

LST sterilization process and programs LST standard programs Program Process description as per DIN 58951-2 Hard goods (metal and glass) Solid waste (decontamination) Open liquids Agar Porous goods Bowie-Dick-Test Vacuum leak test FRVV – VMT FRVV – VOT VOVV – SAK GRAV – SAK FRVV – VMT FRVV – VMT VPR Use Hard goods, porous load, metal, glass Solid waste including low percentage of liquid, petri dishes Liquids in vented or open containers/bottles Agar sterilization; keeps agar warm at cycle end (liquid removal) Hard, porous goods Exhaust test for porous goods Leak test to check the chamber’s...

 Open the catalog to page 10

LST-V and LST-H sterilizer overview Technical characteristics General DGRL 97/23/EG, DIN 58951-2 or ASME Chamber version Material 1.4404 (316L) Ground Ra < 0,8 µm Chamber xtures Ventilator Door design Single or dual door Robust Ground Ra < 0,8 µm Vertical door movement Horizontal door movement Piping and ttings version Material 1.4404 / 1.4435 (316L) Operation side 1 and 2 Colour touch operating panel 5,7” Cycle documentation Matrix printer 42 characters A4 (8.5” x 11”) printer Cycle documentations system ICS 8535 Control SPS control Sensor system Pressure sensors, chamber Sterilization...

 Open the catalog to page 11

All Belimed catalogs and technical brochures

  1. MST-V

    12 Pages

  2. Belimed CA 9600

    2 Pages

  3. RackBrochure

    64 Pages

  4. SWP

    2 Pages

  5. WD390

    14 Pages

  6. WD200

    12 Pages

  7. Brochure DDA7

    4 Pages

  8. WD 390

    14 Pages

  9. LST

    12 Pages

  10. CS 750

    24 Pages

  11. WD 60

    2 Pages

  12. PH 880

    8 Pages

  13. PH 820

    8 Pages

  14. PH 810

    12 Pages

  15. VAPOFIX

    8 Pages

  16. CS 730

    9 Pages

  17. Brochure WD 750

    8 Pages

  18. Brochure WD 430

    12 Pages

  19. Brochure WD 350

    2 Pages

  20. MULTI-TOP

    2 Pages

  21. WD 200

    12 Pages

  22. WD 425

    8 Pages

  23. Pharma

    20 Pages

  24. PST

    16 Pages

  25. WD 150

    8 Pages