BAS-200slm Bio-Acoustic Simulator Sound Level Meter Dual Function Dependability. Monitor Background Noise During Testing. If you’re testing in locations where it’s inconvenient to have a sound booth, then you need to prove that tests were completed within legal limits for ambient noise. The BAS-200slm offers all the dependability of the BAS-200 with a sound level meter. It is a dual-function instrument that creates a legal record of the daily calibration check and of compliance with OSHA ambient noise regulation as required by 29 CFR 1910.95. The BAS-200slm meets the ANSI requirements for both a Type 2 Octave Band Filter and a Type 2 Sound Level Meter so your compliance is documented. Because the BAS-200slm is powered by the Benson Medical 3 Quick and accurate daily calibration check as required by OSHA 3 Ensures compliance with OSHA ambient noise level regulations 3 Power is supplied from audiometer 3 Place on tabletop or mount on wall of test booth 3 No need to remove from system when performing subject testing 3 Meets ANSI standards for both sound level meters and octave band filters 3 Documents compliance with OSHA regulations 3 States in reports that ambient noise levels were not exceeded 3 Stores ambient noise levels with audiogram data 3 Supports OSHA, ANSI, or user-defined maximum Instruments audiometer, there is no worry about battery life. Connecting the response switch to the BAS-200slm returns the system to subject testing. Get Started Today Contact your Benson Medical Instruments dealer for a no-obligation demonstration. 310 Fourth Avenue South Suite 5000 Minneapolis, MN 55415 U.S.A. (612) 827-2222 www.BensonMedical.com
Open the catalog to page 1
Bio-Acoustic Simulator/Sound Level Meter Assured Compliance Simulator Specifications For each audiogram the following data is stored: Sound Level Meter Specifications OSHA regulation 29 CFR 1910.95 Appendix D requires that the ambient noise in the audiometric testing room not exceed certain levels. The BAS-200slm provides iron-clad documentation that the test was performed within the limits set by OSHA. 3 Ambient noise levels for each octave band 3 Maximum permissible ambient noise levels for each octave band 3 BAS-200slm serial number and calibration date The audiometer will re-present...
Open the catalog to page 2All Benson Medical Instruments catalogs and technical brochures
-
CCS-200 Plus
2 Pages
-
CCS-200 Spirometer
2 Pages
-
BAS-200 Bio-Acoustic
1 Pages
-
Solo™ Occupational DBMS
2 Pages