video corpo

PAM 170

PAM 170

PAM 170

Product catalog summary
Key Features
  • Gasless scintillation detector with a compact and lightweight design.
  • User-friendly interface with high sensitivity and uniform response.
  • Fast selection from stored measurement presets and two settable alarm levels.
  • Fast replacement of light-tight foil and optional dose rate measurement.
Purpose

The PAM-170 series activity meters are portable instruments designed for measuring surface contamination. They feature a scintillator with a photomultiplier and two-channel processing electronics. Types A, B, and C have reduced sensitivity to gamma radiation, allowing lower alarm levels compared to types D and E.

  • Type A: Measures only alpha contamination, ideal for nuclear fuel production and uranium processing.
  • Type B: Measures alpha and beta contamination with high sensitivity to beta, suitable for nuclear plants.
  • Type C: Distinguishes between alpha and beta contamination, also suitable for nuclear plants.
  • Type D: Measures alpha, beta, and gamma radiation, suitable for nuclear medicine workplaces.
  • Type E: Measures all contamination types and can discriminate alpha, suitable for training or experimental settings.
Measurement Modes
  • Ratemeter: Continuous measurement for detecting contaminated surfaces.
  • Contamat: Integration measurement for assessing contamination against a threshold.

The meter is controlled via a graphical display with backlit illumination and three buttons. It can display values as count rate or in units of activity, surface activity, emission, and surface emission. Up to 25 presets can be saved for various measurement parameters.

Additional Features
  • Manual background radiation measurement and automatic deduction from results.
  • Optional integrated GM tube for gamma dose equivalent rate measurement.
  • Acoustic pulse indication with dual-channel sound differentiation.
  • Portable carrying case included.
Specifications
  • Detector type: Plastic scintillator and/or ZnS/Ag.
  • Active area: 170 cm2.
  • Dimensions: 130 × 129 × 226 mm; Weight: < 1.4 kg with batteries.
  • Power supply: 2x C size batteries or service cable; Battery life: Approx. 120 hours.
  • Temperature range: -20 to +40 °C.
  • Units: cps, cps/cm2, cpm, cpm/cm2, dpm, Bq, Bq/cm2, pps, pps/cm2.
Measurement of Dose Equivalent Rate
  • Detector type: GM tube.
  • Measurement range: 100 nSv/h to 500 mSv/h.
Related Products
  • PAM-100 Portable Activity Meter
  • PAM-525 Portable Activity Meter
Example of Radiometric Parameters
ModelChannelRadionuclideEfficiency [%]Detection threshold [Bq/cm2]
PAM-170Aα241Am410.01
PAM-170Bα241Am420.03
β36Cl450.02
PAM-170Cα241Am430.01
β36Cl350.03
PAM-170Dα241Am420.07
β36Cl520.04
γ137Cs450.05
PAM-170Eα241Am420.01
β36Cl450.05
γ137Cs380.05
See more

Catalog excerpts

PAM 170-1

NUCLEAR WASTE CALIBRATION RESEARCH INDUSTRY NUCLEAR POWER PLANTS MANAGEMENT LABORATORIES CENTRES & MANUFACTURING MEDICINE • Gasless scintillation detector • Compact, lightweight and resistant design • User friendly, ease of use • High sensitivity, uniform response • Fast selection from stored measurement presets • Two settable alarm levels • Fast replacement of light-tight foil • Optional measurement of the dose rate The PAM-170 series activity meters are portable handheld instruments intended for the measurement of surface contamination. They contain a scintillator covered with light-tight foil, with a photomultiplier and two-channel processing electronics. Types A, B, and C have suppressed sensitivity to gamma radiation and thus low response to gamma background. This allows setting of lower alarm levels comparing to the D and E types. • A measures only alpha contamination and is therefore designed especially for plants for the production and / or processing of nuclear fuel, uranium mining and / or processing. • B measure alpha and beta contamination but cannot discriminate them. It has the highest sensitivity to beta contamination, especially low energies. • C is a two-channel monitor, which can distinguish between alpha and beta contamination. Types B and C are suitable for nuclear plants, where the gamma background may be increased or variable. Types D and E have increased sensitivity to gamma radiation and thus higher response to gamma background. This prevents them from setting as low alarm levels as can be set for the B and C types. • D measures all types of radiation (alpha, beta, gamma) in one channel. It is suitable for nuclear medicine workplaces where Tc-99m radionuclide and possibly others pure gamma emitters are used. • E measures all types of contamination and can discriminate alpha. It is suitable for training or experimental workplaces. The meter allows the measurement of the surface contamination in two modes: • Ratemeter - continuous measurement of the average pulse frequency to aid searching for a contaminated surface. • Contamat - integration measurement for deciding on contamination or cleanliness of a specific area in comparison with the set threshold. The meter is controlled using a graphical display with the possibility of backlit illumination and three push buttons. One or two channels can be displayed on the display simultaneously. The measured values can be displayed as count rate, or for specific selected radionuclides in units of activity, surface activity, emission and surface emission. The display shows the selected quantity digitally and/or as a bar-graph. PAM-170 can save up to 25 different presets for measurement mode, quantity and unit, radionuclide, response factor and alarm levels. For each channel the background radiation level can be measured manually and stored in memory. This background is then automatically deducted from the measurement results indicated on the display. The PAM-170 meters can optionally contain an integrated GM tube for measurement of the gamma dose equivalent rate. It is an additional measurement, which can give a warning to the operator of higher ambient radiation levels. The meter can also acoustically indicate pulses generated by the detector. Dual-channel monitors distinguish between pulse detection in the alpha channel and in the beta channel by a different sound. To carry the monitor you can use a portable carrying case that is included in the del

 Open the catalog to page 1
PAM 170-2

Battery life Temperature range from -20 to +40 °C The currently measured values in the "Ratemeter" mode and the results of the integration measurements in the "Contamat" mode can be stored in the measurement archive together with a time stamp. The archive can then be exported to a file. Service software is used to export the archive, and set the essential parameters or update firmware by means of a PC/notebook connected by a service port. Name 1. channel 2. channel PAM-170D alpha + beta + gamma - PAM-170E beta + gamma alpha OPTIONAL ACCESSORIES Part Number Name 50- A-0016294 Shoulder strap with...

 Open the catalog to page 2

All Bertin Technologies catalogs and technical brochures

  1. PNM-02

    2  Pages

  2. Exitscan

    4  Pages

  3. FloorScan-525

    2  Pages

  4. WAM-400

    2  Pages

  5. WAM-200

    2  Pages

  6. WAM-300

    2  Pages

  7. ASSAY KIT

    2  Pages

  8. V3H14C

    4  Pages

  9. RDU 02

    2  Pages

  10. MAK 201

    2  Pages

  11. PAM 100

    2  Pages

  12. PAM 525

    2  Pages

  13. HF-6

    2  Pages

  14. HF-4

    2  Pages

  15. RIUMSTICK

    2  Pages

  16. AlphaS

    2  Pages

  17. AlphaGUARD

    2  Pages

  18. AlphaE

    2  Pages

  19. SaphyGATE GN

    2  Pages

  20. SaphyGATE G

    2  Pages

  21. SpectroTRACER

    2  Pages

  22. GammaTRACER

    2  Pages

  23. DataView

    2  Pages

  24. DataEXPERT 10

    2  Pages

  25. Skydose

    2  Pages

  26. SaphyRAD S

    2  Pages

  27. SaphyRAD C

    2  Pages

  28. Antibodies

    7  Pages

  29. MINILYS®

    2  Pages

  30. Coriolis+

    2  Pages

Archived catalogs

  1. Cryolys

    2  Pages

  2. Precellys®24

    2  Pages

  3. Minilys

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.