1. Catalogs
  2. Bettersize
  3. Bettersizer 2600
video corpo

Bettersizer 2600

Bettersizer 2600
1 / 11 PagesView full catalog

Bettersizer 2600

Product catalog summary
Introduction
The Bettersizer 2600 is a versatile instrument for particle analysis, utilizing laser diffraction and dynamic imaging technologies to measure particle size and shape. It is widely used across various industries for quality control and development purposes.
Specifications
The Bettersizer 2600 measures particle sizes ranging from 0.02 to 2,600 μm using laser diffraction, with 92 photoelectric detectors and Mie scattering theory for accurate distribution. The dynamic imaging module extends the range to 3,500 μm for comprehensive analysis. It complies with ISO 13320 and ISO 13322-2 standards.
Applications and Industries
This instrument is applicable in pharmaceuticals, abrasives, batteries, building materials, paints, inks, coatings, mining, minerals, food, beverages, 3D printing materials, ceramics, and cosmetics, optimizing particle size distribution for product performance, safety, and quality.
Technological Features
The Bettersizer 2600 combines laser diffraction and dynamic imaging systems, minimizing total internal reflection for enhanced reliability. It measures refractive indices for samples with unknown properties and complies with RoHS, CE, and USP <429> standards.
Performance
Offering a wide measurement range from 0.02 μm to 2,600 μm, the Bettersizer 2600 provides high resolution and sensitivity, detecting oversized particles and analyzing 24 particle parameters.
Dispersion Systems
It includes wet and dry dispersion modules. Wet modules handle liquid volumes from 8 mL to 600 mL, with semi-automated and fully automated options. Dry modules are fully automated, handling powder masses from 0.02 g to 10 g.
Modules
The BT-902 and BT-903 are dry dispersion units for different sample volumes, using compressed gas for dispersion. The PIC-1 dynamic imaging module integrates for real-time size and shape analysis.
Software
Bettersizer software automates tasks, supports automated and manual operations, and enhances data quality through system cleaning, optical alignment, and sample dispersion. It provides real-time insights and customizable report generation, compliant with 21 CFR Part 11.
Key Features
The system offers versatile test setups, automatic pre-processing, real-time testing, and comprehensive data analysis. It supports SOP settings, refractive index measurement, and sample ratio calculation.
Conclusion
The Bettersizer 2600 is a comprehensive tool for particle analysis, offering advanced features and flexibility to meet diverse industry needs. Its dual optical systems and modular design make it indispensable for precise and reliable particle characterization.
See more

Catalog excerpts

Bettersizer 2600-1

BETTER PARTICLE SIZE SOLUTIONS Particle Analysis for Your Every Need PARTICLE SIZE PARTICLE SHAPE

 Open the catalog to page 1
Bettersizer 2600-2

Particle Analysis for Your Every Need The Bettersizer 2600 employs a well-established particle measurement technology— "Ultra-Met has been using the Bettersize Laser Particle Size analyzer for over 1 year. We Laser Diffraction Technology, covering a particle size range of 0.02 - 2,600 μm. There are able to obtain accurate, repeatable results of our tungsten carbide spray dry powder. are 92 photoelectric detectors to convert light signals from the scattering spectrum to This is a crucial tool for our company for development and quality control for our powder electrical signals, which are transmitted...

 Open the catalog to page 2
Bettersizer 2600-3

Industries Samples Industries Samples Pharmaceuticals Lactose, powder inhalers, magnesium stearate, microcrystalline cellulose, etc. The particle size and size distribution of pharmaceuticals could affect the dissolution, body absorption, efficacy, and safety of drugs. The Bettersizer 2600 is capable of closely monitoring the particle sizes during the processes of pharmaceuticals development. Mining & Minerals Calcium carbonate, kaolin, talc, quartz powder, graphite, barite, wollastonite, hydromagnesite, diatomite, mica, zirconium silicate, etc. Minerals are used in many industries, including...

 Open the catalog to page 3
Bettersizer 2600-4

Why the Bettersizer 2600? The Bettersizer 2600 excels in particle analysis through its dual optical systems: laser diffraction and dynamic imaging. The combination of dual optical systems allows for comprehensive particle characterization, making the Bettersizer 2600 a versatile and indispensable tool for advanced particle analysis. The laser diffraction system, supported by two robust patents, ensures precise and reliable particle size results in compliance with ISO 13320, enabling a wide range of industries and applications to achieve new levels of performance. Owing to its modular design,...

 Open the catalog to page 4
Bettersizer 2600-5

Laser Diffraction System Dynamic Imaging System Superior Performance in Particle Size Analysis PIC-1: Modular Dual-Camera Imaging System Design The PIC-1 features a dual-camera dynamic Dual-Camera Imaging System Ⅰ. Wide Measurement Range imaging system, making it a leading dynamic imaging module that seamlessly integrates with Very fine gravel 2,600 μm laser system design with 92 Coarse abrasive powder 439 μm detectors and a very wide angular range from 0.016° to 165°, it achieves a measurement range images to digital format for real-time analysis. both nano and millimeter scales. Samples Samples...

 Open the catalog to page 5
Bettersizer 2600-6

Imaging Module Wet Dispersion System The wet dispersion process begins with adding water or an organic solvent as the dispersing medium. A stirrer prevents settling, and an ultrasonic transducer aids dispersion and removes bubbles. The dispersed particles then flow into the optical systems for measurement and are recirculated to ensure continuous analysis. Dry powder samples are loaded into a sample container, which feeds them into the main disperser through vibration or high-pressure air produced by an air compressor. Inside the disperser, the particles are separated and any clumps are broken...

 Open the catalog to page 6
Bettersizer 2600-7

Dry Dispersion Modules BT-802 - Automatic Wet Dispersion Unit BT-902 - Automatic Dry Dispersion Unit BT-802 is designed for particle dispersion with water as the medium. It is made up of ABS shells. The components of it include centrifugal pump, peristaltic pump, ultrasonic disperser, pinch valve, control circuit, etc. BT-804 - Small Volume Wet Dispersion Module Effective Particle Dispersion BT-804 is designed for valuable or small-volume sample measurements, where the medium is water or organic solvent. The Bettersizer 2600's advanced wet and dry dispersion systems are engineered to optimize...

 Open the catalog to page 7
Bettersizer 2600-8

PIC-1 Dynamic Imaging Module The PIC-1 dynamic imaging module is a versatile and comprehensive dynamic image analysis instrument, designed for seamless integration with the Bettersizer 2600 laser particle size analyzer and the wet dispersion system. It primarily comprises two high-speed cameras, white and blue LED lights, and a sample cell, among other components. Utilizing dynamic image analysis, the PIC-1 precisely captures high-resolution images of particles in real time as they flow through the sample cell, allowing for detailed analysis of both particle size distribution and shape characteristics....

 Open the catalog to page 8
Bettersizer 2600-9

Bettersizer software is engineered to enhance your entire measurement process, from pre-processing to final data analysis. By seamlessly automating routine tasks and integrating with the Bettersizer 2600, the software empowers you to focus on scientific intricacies. Experience a streamlined workflow that delivers precise and reliable results with Bettersizer software, accelerating your research, and driving innovation. 1. Versatile Test Setup Users can easily create new tests based on laser diffraction and dynamic image analysis methods. The software supports both automated and manual operations,...

 Open the catalog to page 9
Bettersizer 2600-10

• Complete and detailed data: Frequency and cumulative distribution curves, simplified and complete distribution table, etc. • Editability: Users can easily edit the reports and change the font, layout, format, etc. Analysis Mie scattering theory and Fraunhofer diffraction theory; Image analysis • Convertibility: Users can switch the formats of reports freely among PDF, Excel, Text, etc. Bettersize Bette rsizer 2600{Wet) Particle Size Analysis Report Typical measurement time Measuring range 0.02 - 2,600 pm (wet)*; 0.1 - 2,600 pm (dry)*; 2 - 3,500 pm (dynamic image)* Number of size classes 100...

 Open the catalog to page 10
Bettersizer 2600-11

Bettersize Instruments Ltd. No. 9, Ganquan Road, Jinquan Industrial Park, Dandong, Liaoning, China Postcode: 118009 Tel: +86-755-26926582 Bettersize Inc. 3185 Airway Ave, Suite C2, Costa Mesa, CA 92626, United States Tel: +1 833-699-7493 (SIZE) [email protected] www.bettersizeinstruments.com Visit Our Bettersizer 2600 Site Visit Our Official YouTube Channel Disclaimer: By using or accessing the brochure, you agree with the Disclaimer without any qualification or limitation. Diligent care has been used to ensure that the information in this brochure is accurate, Bettersize Instruments Ltd. shall...

 Open the catalog to page 11

All Bettersize catalogs and technical brochures

  1. BetterPyc 380

    9  Pages

  2. HFlow-1

    2  Pages

  3. PowderPro A1

    5  Pages

  4. BeVision M1

    7  Pages

  5. BeVision S1

    7  Pages

  6. PowderPro A1

    5  Pages

  7. benano-series

    11  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About MedicalExpo
MedicalExpo is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. MedicalExpo is an entity of VirtualExpo Group.