Catalog excerpts

Implants for primary surgery Catalogue - primary implants
Open the catalog to page 1
■ List of materials MATERIAL
Open the catalog to page 2
Femoral components Plugs and collar washers Acetabular components Femoral components Tibial components Patellar components RADIAL HEAD
Open the catalog to page 3
type CSB one - piece (see page 7) type POLDI (see page 10) type BEZNOSKA TRIO cemented (see page 11) Cementless femoral stems type BEZNOSKA TRIO cementless (see page 12) type CSB modular (see page 8) Cemented femoral stems type POLDI (see page 6) type BEZNOSKA TRIO cementless HA (see page 13) type BEZNOSKA TRIO modular (see page 14) typ BEZNOSKA TRIO modular HA (see page 15)
Open the catalog to page 4
Cemented cups type POLDI (see page 19) Cementless shells Hip joint head replacements
Open the catalog to page 5
Cemented hip hemiarthroplasty - type Poldi Material: Order number
Open the catalog to page 6
Cemented hip hemiarthroplasty - type CSB Material: Stem - Stainless steel (ISO 5832-1) Centralizer - PMMA Order number 60* 315922 *available as custom-made option only 9 Order number
Open the catalog to page 7
■ Cemented stem - type CSB Material: Stem - Wrought high nitrogen stainless steel (ISO 5832-9) Centralizer - PMMA
Open the catalog to page 8
■ Cemented stem - type CSC Material: Stem - Wrought high nitrogen stainless steel (ISO 5832-9)
Open the catalog to page 9
■ Cemented stem - type Poldi Material: Wrought high nitrogen stainless steel (ISO 5832-9)
Open the catalog to page 10
Material: Stem - Wrought high nitrogen stainless steel (ISO 5832-9) Cemented stem Centralizer PMMA
Open the catalog to page 11
■ Cementless stem - type BEZNOSKA TRIO Material: Wrought titanium Ti6Al4V alloy (ISO 5832-3)
Open the catalog to page 12
■ Cementless modular stem - type BEZNOSKA TRIO Material: Stem - Wrought titanium Ti6Al4V alloy (ISO 5832-3) Neck - Wrought titanium Ti6Al4V alloy (ISO 5832-3) standard ante/retro varus/valgus varus/ante valgus/retro © varus/retro valgus/ante d
Open the catalog to page 14
ante/retro varus/valgus varus/ante valgus/retro D ® varus/ante valgus/retro varus/retro valgus/ante ©
Open the catalog to page 15
■ Cementless stem - type SF Material: Wrought titanium Ti6Al4V alloy (ISO 5832-3)
Open the catalog to page 16
■ Femoral stem collar washerMaterial: UHMWPE (ISO 5834-2) S [mm]
Open the catalog to page 17
■ Cemented cup - type 02 Material: Cup - Crosslinked UHMWPE (ISO 5834-2)
Open the catalog to page 18
Cemented cup - type Poldi Material: Order number Order number Order number Order number Order number Order number
Open the catalog to page 19
■ Cementless shell - type SF Material: Unalloyed titanium (ISO 5832-2) Cementless shell - standard Cementless shell - flat
Open the catalog to page 20
Insert - type SF - standard Material: Crosslinked UHMWPE (ISO 5834-2) Shell diameter -D [mm] Shell diameter - 0 A Order Insert - type SF with offset 10° Insert - type SF - flat
Open the catalog to page 21
■ Screw - type SF Material: Wrought titanium alloy Ti6Al4V (ISO 5832-3) Cortical screw for cementless shell - type SF
Open the catalog to page 22
Cobalt head CoCrMo
Open the catalog to page 23
■ Hip joint head replacementsMaterial: Ceramic head: BIOLOX(R) delta Hemiarthroplasty head: Stainless steel (ISO 5832-1) Biarticular head: Head cover - Stainless steel (ISO 5832-1) Head inner - Wrought high nitrogen stainless steel (ISO 5832-9) Head liner - UHMWPE (ISO 5834-2) Ceramic head
Open the catalog to page 24
Total knee joint replacement: - type SVL (with LCP) - type SVS (without LCP) - type SVL/N (computer assisted) Total knee joint replacement: - type SVL/RP (with rotary tibial plateau)
Open the catalog to page 25
Admissible combinations of SVL components with other knee replacement components made by BEZNOSKA Ltd. Patellar component Femoral component type SVS Femoral component type SVL/N PE liner type SVL/RP Tibial component type SVL/RP Tibial component type SVL
Open the catalog to page 26
■ Femoral component - type SVSMaterial: Co-Cr-Mo casting alloy (ISO 5832-4) Size
Open the catalog to page 27
■ Tibial component - type SVL Material: Wrought titanium Ti6Al4V alloy (ISO 5832-3) ■ Tibial component modular - type SVL Material: Wrought titanium Ti6Al4V alloy (ISO 5832-3)
Open the catalog to page 28
■ Stem of tibial component - type SVLMaterial: Wrought titanium Ti6Al4V alloy (ISO 5832-3) 0D [mm]
Open the catalog to page 29
■ Insert - type SVL Material: UHMWPE (ISO 5834-2) Left insert
Open the catalog to page 30
Left insert
Open the catalog to page 31
■ Insert - type SVL/RP Material: UHMWPE (ISO 5834-2) Left insert Right insert
Open the catalog to page 32
Material: UHMWPE (ISO 5834-2) Size Note: For femoral coponents SVL/N, SVS and SVR.
Open the catalog to page 33
■ Cemented shoulder hemiarthroplasty Material: Stainless steel (ISO 5832-1)
Open the catalog to page 34
Material: Co-Cr-Mo casting alloy (ISO 5832-4) Size
Open the catalog to page 35
■ Radial head Material: Wrought high nitrogen stainless steel (ISO 5832-9)
Open the catalog to page 36
Wrought high nitrogen stainless steel (ISO 5832-9) 0 D [mm]
Open the catalog to page 37
■ TMCJ - Cementless stem - type T/II (Ti + HA) Material: Wrought titanium Ti6Al4V alloy (ISO 5832-3) + HA ■ TMCJ - Cementless stem - type T Material: Wrought titanium Ti6Al4V alloy (ISO 5832-3)
Open the catalog to page 38
Material: Wrought Co-Cr-Mo alloy (ISO 5832-12) ■ TMCJ - Cementless shell - type T/III Material: Wrought titanium Ti6Al4V alloy (ISO 5832-3) + HA
Open the catalog to page 39
■ TMCJ - Insert of cup - type T/III, for head 5 mm Material: Crosslinked UHMWPE (ISO 5834-2)
Open the catalog to page 40
Material: Wrought Co-Cr-Mo alloy (ISO 5832-12) ■ TMCJ - Insert of trapezium - type TR Material: Crosslinked UHMWPE (ISO 5834-2)
Open the catalog to page 41
BEZNOSKA, s.r.o. Delnicka 2727, 272 01 Kladno, Czech Republic www.beznoska.com, export@beznoska.cz
Open the catalog to page 44All Beznoska catalogs and technical brochures
-
SKIN STAPLER 35W
1 Pages
-
Cementless cup – type SF
20 Pages
-
Radial Head Replacement
12 Pages
-
Humeral head resurfacing
12 Pages
-
Hip Joint Head Replacements
8 Pages
-
Cemented femoral stem - type CSC
16 Pages
-
Hip Hemiarthroplasty – type CSB
20 Pages
-
Cerclage System
12 Pages
-
UNIQUE MANUFACTURING METHOD
1 Pages
-
Implants for Traumatology
16 Pages
-
Revision systems
32 Pages
-
Individual oncological implants
24 Pages