
Catalog excerpts

Implants for Traumatology '.VtTU> 4 Catalogue - implants
Open the catalog to page 1
Reconstruction Nails CR Screws for CR Nails ■ List of materials MATERIAL
Open the catalog to page 2
Reconstruction Nails CR Screws for CR Nails ■ Cortical Screw Material: Stainless steel (ISO 5832-1) Order number Order number
Open the catalog to page 4
Reconstruction Nails CR Screws for CR Nails ■ Cannulated Cancellous Screw Material: Stainless steel (ISO 5832-1)
Open the catalog to page 6
■ MiniscrewMaterial: Wrought titanium 6AI-4V alloy (ISO 5832-3) Diameter D [mm] ■ Locking MiniscrewMaterial: Wrought titanium Ti6Al4V alloy (ISO 5832-3) Diameter D [mm]
Open the catalog to page 7
Reconstruction Nails CR Screws for CR Nails ■ Straight Miniplate Material: Unalloyed titanium (ISO 5832-2) ■ L - Oblique Miniplate Material: Unalloyed titanium (ISO 5832-2)
Open the catalog to page 8
■ Y - Miniplate Material: Unalloyed titanium (ISO 5832-2) ■ T - Miniplate Material: Unalloyed titanium (ISO 5832-2) ■ T - Oblique Miniplate Material: Unalloyed titanium (ISO 5832-2)
Open the catalog to page 9
Reconstruction Nails CR Screws for CR Nails ■ Sagittal Split Miniplate Material: Unalloyed titanium (ISO 5832-2) ■ Y - Oblique Miniplate Material: Unalloyed titanium (ISO 5832-2)
Open the catalog to page 10
■ Oncological Straight Miniplate Material: Unalloyed titanium (ISO 5832-2) ■ Oncological Oblique Miniplate left (L) / right (R)
Open the catalog to page 11
Reconstruction Nails CR Screws for CR Nails ■ Reconstruction Nail CR - short Material: Wrought titanium Ti6Al4V alloy (ISO 5832-3) ■ Screw CR - proximal Material: Wrought titanium Ti6Al4V alloy (ISO 5832-3)
Open the catalog to page 12
■ Screw CR - distal Material: Wrought titanium Ti6Al4V alloy (ISO 5832-3) Order number ■ Plug Screw CR Material: Wrought titanium Ti6Al4V alloy (ISO 5832-3) Material: Wrought titanium Ti6Al4V alloy (ISO 5832-3)
Open the catalog to page 13
Reconstruction Nails CR Screws for CR Nails ■ Cortical Nut Material: Stainless steel (ISO 5832-1) ■ Screw Washer Material: Stainless steel (ISO 5832-1) ■ Guide Wire Material: Stainless steel (ISO 5832-1) ■ Cerclage Wire Material: Stainless steel (ISO 5832-1)
Open the catalog to page 14
■ Kirschner Wire - triangular pointMaterial: Stainless steel (ISO 5832-1) Length [mm] ■ Kirschner Wire - lance point Material: Stainless steel (ISO 5832-1) 15
Open the catalog to page 15
BEZNOSKA, s.r.o. Delnicka 2727, 272 01 Kladno, Czech Republic www.beznoska.com, export@beznoska.cz
Open the catalog to page 16All Beznoska catalogs and technical brochures
-
SKIN STAPLER 35W
1 Pages
-
Cementless cup – type SF
20 Pages
-
Radial Head Replacement
12 Pages
-
Humeral head resurfacing
12 Pages
-
Hip Joint Head Replacements
8 Pages
-
Cemented femoral stem - type CSC
16 Pages
-
Hip Hemiarthroplasty – type CSB
20 Pages
-
Cerclage System
12 Pages
-
UNIQUE MANUFACTURING METHOD
1 Pages
-
Revision systems
32 Pages
-
Implants for primary surgery
44 Pages
-
Individual oncological implants
24 Pages