Individual oncological implants - 24 Pages

Add to MyMedicalExpo favorites
Individual oncological implants

Catalog excerpts

Individual oncological implants Catalogue - individual oncological implants

 Open the catalog to page 1

■ CONTENTS KNEE Knee type CMS, cemented with partial replacement of femur    4 - 5 Knee type CMS, cemented with partial replacement of femur and tibia    6 - 7 Knee type CMS, cemented with partial replacement of tibia    8 - 11 Knee type CMS, with total replacement of femur    12 - 13 HIP Cemented femoral stem with partial replacement of proximal femur, taper neck    14 - 15 SHOULDER Cemented shoulder hemiarthroplasty with partial replacement of proximal humerus    16 - 17 ELBOW Elbow arthroplasty with partial replacement of humerus    18 - 19 Elbow arthroplasty with total replacement of...

 Open the catalog to page 3

Knee type CMS, cemented with partial replacement of femur

 Open the catalog to page 4

■ Knee type CMS, cemented with partial replacement of femur Material: Stainless steel - stem (ISO 5832-1), UHMWPE - partial replacement (ISO 5834-2) and distance ring (ISO 5834-2), Wrought high nitrogen stainless steel (ISO 5832-9), Co-Cr-Mo casting alloy (ISO 5832-4) Hinged with rotation Femoral and tibial part of CMS knee must have same size. It is not possible to combine diferent sizes of CMS. Order number TIBIAL RESECTION

 Open the catalog to page 5

Knee type CMS, cemented with partial replacement of femur and tibia

 Open the catalog to page 6

■ Knee type CMS, cemented with partial replacement of femur and tibia Material: Stainless steel - stem (ISO 5832-1), UHMWPE - partial replacement (ISO 5834-2) and distance ring (ISO 5834-2), Wrought high nitrogen stainless steel (ISO 5832-9), Co-Cr-Mo casting alloy (ISO 5832-4) Hinged with rotation Femoral and tibial part of CMS knee must have same size. It is not possible to combine diferent sizes of CMS. Order number Pocet distancnfch krouzkfl Distance rings pcs 0    12    3

 Open the catalog to page 7

Knee type CMS, cemented with partial replacement of tibia

 Open the catalog to page 8

Knee type CMS, cemented with partial replacement of tibia

 Open the catalog to page 9

Knee type CMS, cemented with partial replacement of tibia Material: Stainless steel - stem (ISO 5832-1), UHMWPE - partial replacement (ISO 5834-2) and distance ring (ISO 5834-2), Wrought high nitrogen stainless steel (ISO 5832-9), Co-Cr-Mo casting alloy (ISO 5832-4) Hinged with rotation Femoral and tibial part of CMS knee must have same size. It is not possible to combine diferent sizes of CMS.

 Open the catalog to page 10

■ Knee type CMS, cemented with partial replacement of tibia Material: Stainless steel - stem (ISO 5832-1), UHMWPE - partial replacement (ISO 5834-2) and distance ring (ISO 5834-2), Wrought high nitrogen stainless steel (ISO 5832-9), Co-Cr-Mo casting alloy (ISO 5832-4) Hinged with rotation Femoral and tibial part of CMS knee must have same size. It is not possible to combine diferent sizes of CMS. Order number TIBIAL RESECTION

 Open the catalog to page 11

Knee type CMS, with total replacement of femur

 Open the catalog to page 12

HIP/Oncological ■ Knee type CMS, with total replacement of femur Material: Stainless steel - stem (ISO 5832-1), UHMWPE - partial replacement (ISO 5834-2), Wrought high nitrogen stainless steel (ISO 5832-9), Co-Cr-Mo casting alloy (ISO 5832-4)

 Open the catalog to page 13

Cemented femoral stem with partial replacement of proximal femur, taper neck

 Open the catalog to page 14

 Cemented femoral stem with partial replacement of proximal femur, taper neck Material: Stainless steel - stem (ISO 5832-1), UHMWPE - partial replacement and distance ring (ISO 5834-2) It is possible to deliver the replacement with 1 - 3 distance rings (thickness of each - 10 mm) in cylindrical part in order to widen the variability of resection. Highlighted sizes are recomended by manufacturer. Order number 340050

 Open the catalog to page 15

 Cemented shoulder hemiarthroplasty with partial replacement of proximal humerus

 Open the catalog to page 16

■ Cemented shoulder hemiarthroplasty with partial replacement of proximal humerus Material: Stainless steel - stem (ISO 5832-1), UHMWPE - partial replacement (ISO 5834-2) and distance ring (ISO 5834-2) It is possible to deliver the replacement with I - 2 distance rings (thickness of each 5 -10 mm) in cylindrical part in order to widen the variability of resection.

 Open the catalog to page 17

Elbow arthroplasty with partial replacement of humerus

 Open the catalog to page 18

Elbow arthroplasty with partial replacement of humerus Material: Stainless steel - stem (ISO 5832-1), UHMWPE - partial replacement (ISO 5834-2) It is possible to deliver the replacement with 1 - 2 distance rings (thickness of each is 8 mm) in cylindrical part in order to widen the variability of resection.

 Open the catalog to page 19

Elbow arthroplasty with total replacement of humerus

 Open the catalog to page 20

Elbow arthroplasty with total replacement of humerus Material: Stainless steel - stem (ISO 5832-1), UHMWPE - partial replacement (ISO 5834-2)

 Open the catalog to page 21

Partial replacement of pelvis based on patient's CT data Material: Wrought titanium Ti6Al4V alloy (ISO 5832-3)

 Open the catalog to page 22

Partial replacement of pelvis based on patient's CT data One of the important services that our company provides to customers is delivery of individual customized implants designated for use by concrete patients. The advantage of these products is their adjustment to the concrete patient's anatomical and biomechanical setup, as well as indications, including any allergic predispositions. Of course, specific solution requirements call for a specific approach to the input data. Particularly important are the dimensions that the given joint replacement is designed for. The necessary...

 Open the catalog to page 23

BEZNOSKA, s.r.o. Delnicka 2727, 272 01 Kladno, Czech Republic www.beznoska.com, export@beznoska.cz

 Open the catalog to page 24

All Beznoska catalogs and technical brochures

  1. Cerclage System

    12 Pages

  2. Revision systems

    32 Pages