MAINTENANCE OF TURBINES.
1 / 3Pages

Catalog excerpts

MAINTENANCE OF TURBINES. - 1

Refer to the user manual for the product for the complete cleaning and sterilisation maintenance procedures. This medical device is supplied in "non sterile" condition. Please ensure that this procedure is followed before the device is used. • Remove the rotary instrument from the chuck mechanism B. PRE-DISINFECTION • External disinfection D o not immerse the instrument in a disinfectant bath. CLEANING A. CLEAN UNDER RUNNING WATER AT <38°C B. REMOVING DIRT/DEPOSITS • Carefully remove all traces of dirt or deposits from the spray nozzles using the Bien-Air cleaning wire • Dry the nozzles with compressed air then dry the rest of the instrument with a cloth Do not immerse in an ultrasonic cleaner C . NTERNAL AND EXTERNAL CLEANING WITH I SPRAYNET • Shake the Spraynet before use • Use the Spraynet attachment ( for 2-/3-way and 4-way turbines, see inset below) • Keep the tip of the instrument pointing down and protect with an absorbent cloth; press the Spraynet button down for 1 second • Clean the exterior of the turbine with a cloth soaked in Spraynet C‘. LEANING THE INSIDE WITH SPRAYNET C FOR 2-/3-WAY AND 4-WAY TURBINES ONLY • Use the Spraynet attachment • Keep the tip of the instrument pointing down and protect with an absorbent cloth; press the Spraynet button down for 1 second S pray into the opening as shown in the illustrations for “2-/3-way” and “4-way” * All the references for the attachments are given on the last page

Open the catalog to page 1
MAINTENANCE OF TURBINES. - 2

DISINFECTION A.DISINFECTION USING SURFACE DISINFECTANT (follow the manufacturer's instructions for use) D o not immerse the instrument in a disinfectant bath OR B. THERMAL DISINFECTION (follow the manufacturer's instructions for use) A. LUBRICATION WITH LUBRIMED OR B. LUBRICATION WITH LUBRIFLUID • Shake the Lubrifluid before use • Use the Lubrifluid attachment 2 , 3 or 4 depending on the type of instrument * (For 2-/3-way and 4-way turbines, see inset below) • Keep the tip of the instrument pointing down and protect with an absorbent cloth; press the Lubrifluid button down for 1 second •...

Open the catalog to page 2
MAINTENANCE OF TURBINES. - 3

MAINTENANCE ACCESSORIES SPRAYNET 500 ml cleaning spray Pack of 6 LUBRIFLUID 500 ml lubricant Pack of 6 AQUACARE 500 ml cleaning spray Pack of 6 Bora L / LK, Boralina, Prestige L / LK, Tornado L / LK Bora L, Boralina, Prestige L, Tornado L, Boralina LUBRICARE Maintenance system LUBRIMED Pack of 6 cartridges BIEN-AIR CLEANING WIRE Pack of 10

Open the catalog to page 3

All Bien-Air Dental catalogs and technical brochures

  1. Tornado

    5 Pages

  2. Lubricare_2

    3 Pages

  3. Bora2

    5 Pages

  4. Nova

    7 Pages

  5. CHIROPRO PLUS

    11 Pages

Archived catalogs

  1. Optima

    7 Pages

  2. Laboratory

    2 Pages

  3. EVO 15

    11 Pages

  4. ENT CATALOGUE

    13 Pages

  5. WIRE DRIVER

    2 Pages

  6. CATALOGUE

    22 Pages

  7. MILL200

    2 Pages

  8. MILL300

    2 Pages

  9. OSSEO DUO

    8 Pages

  10. MICROMOTORS

    12 Pages