CB 220 - 6 Pages

Add to MyMedicalExpo favorites
CB 220

Catalog excerpts

Data Sheet Model CB 220 Model CB 220 | CO2 incubators with hot air sterilization and heat sterilizable CO2 sensor BENEFITS • Hot air sterilization at 180 °C, with sterilizable built-in CO2 sensor minimizes the risk of contamination • Homogeneous temperature distribution thanks to VENTAIR™ air jacket system • Stable pH-values thanks to drift-free CO2 IR sensor technology • Saturated relative humidity up to 95 % RH • Easy cleaning thanks to seamless, deep-drawn inner chamber MAIN FEATURES • Temperature range: room temperature plus 7 °C to 60 °C • Tightly-sealed inner door made of tempered safety glass • Seamless, deep-drawn inner stainless steel chamber • 3 perforated stainless steel shelves • Double-pan humidification system with condensation protection • Units are stackable with stacking adapter • CO2 gas-mixing jet with Venturi effect • Troubleshooting system with visual and audible alarms • Hot-air sterilizable CO2 sensor with infrared technology • Computer interface: Ethernet • Humidity sensor with infrared technology • Internal data recording and USB interface • Display via color LCD monitor • Zero-voltage alarm contact • Lockable door handle ORDERING INFORMATION Interior volume [L] Option model with 6x divided inner door with O2 control and with 6x divided inner door with 6x divided inner door with O2 control and with 6x divided inner door BINDER Data Sheet | As of: 02.03.2016 Technica

 Open the catalog to page 1

Data Sheet Model CB 220 TECHNICAL DATA (Version 1-4 from 8) Description Article Number Temperature range 7 °C above ambient temperature to [°C] Recovery time after 30 seconds door open at 37 °C [min] Recovery time after 30 seconds door open at 5 Vol.-% CO2 [min] Performance Data Temperature Recovery time after 30 seconds door open at 5 Vol.-% O2 [min] Performance Data Climate Humidity range [% RH] Phase (Nominal voltage) Wall clearance back [mm] Wall clearance sidewise [mm] Inner doors Unit doors Net weight of the unit (empty) [kg] Gas Data - O2-Data O2 range [Vol.-% O2] Electrical data...

 Open the catalog to page 2

Data Sheet Model CB 220 TECHNICAL DATA (Version 5-8 from 8) Description Article Number Temperature range 7 °C above ambient temperature to [°C] Recovery time after 30 seconds door open at 37 °C [min] Recovery time after 30 seconds door open at 5 Vol.-% CO2 [min] Performance Data Temperature Recovery time after 30 seconds door open at 5 Vol.-% O2 [min] Performance Data Climate Humidity range [% RH] Phase (Nominal voltage) Wall clearance back [mm] Wall clearance sidewise [mm] Inner doors Unit doors Net weight of the unit (empty) [kg] Gas Data - O2-Data O2 range [Vol.-% O2] Electrical data...

 Open the catalog to page 3

Data Sheet Model CB 220 OPTIONS AND ACCESSORIES Designation 30 mm, back Access port with silicone plug for temperature and CO2 values (outputs not adjustable) with casters Calibration certificate, expanded each measurement at additional measuring point or testing temperature for optional O2 control, O2 measurement with test gas 1 % O2 for temperature, measurement in center of chamber at specified temperature temperature measurement incl. certificate and 27 measuring points at specified temperature temperature measurement incl. certificate, 15- 18 measuring points at specified temperature...

 Open the catalog to page 4

Data Sheet Model CB 220 Stacking adapter, flat for thermally decoupled stacking of two identical units Stacking frame stable, vibration-free stacking frame on casters with stop brake for safe stacking of two CB series units and set up of unit at operating location, connect to existing connections unit function instructions for operation and programming of the controller Execution of equipment inspection according to maintenance plan including certificate, CO2 measurement with analyzed test gas at 5 % or at specified value calibration of O2, including certificate (one measuring point in...

 Open the catalog to page 5

Data Sheet Model CB 220 Condensation may occur in the area around the access port. Access ports may be placed in custom locations for an additional charge. UL mark is not granted when this option is used. Heat resistant only to max. 200 °C. Only available on units rated for 230 V. Attention: The pump is delivered separately. The electric connection for the pump (230 V/1~/50 Hz) must be carried out by an authorized electrician. Heating-up time may increase as a result of the lower heat conductivity. The additional heat input may affect the temperature behavior. The pump (packaged separately)...

 Open the catalog to page 6

All BINDER GmbH catalogs and technical brochures

  1. C 170

    5 Pages

  2. VDL 115

    5 Pages

  3. VDL 53

    5 Pages

  4. FDL 115

    5 Pages

  5. VD 23

    5 Pages

  6. VD 53

    5 Pages

  7. VD 115

    5 Pages

  8. VDL 23

    5 Pages

  9. M 115

    6 Pages

  10. M 240

    5 Pages

  11. FP 115

    6 Pages

  12. FP 53

    6 Pages

  13. E 28

    4 Pages

  14. UF V 700

    7 Pages

  15. UF V 500

    7 Pages

  16. KBWF 720

    6 Pages

  17. KBWF 240

    6 Pages

  18. KBW 720

    6 Pages

  19. KBW 400

    6 Pages

  20. KBW 240

    6 Pages

  21. KB 720

    5 Pages

  22. KB 400

    6 Pages

  23. KB 240

    5 Pages

  24. KB 53

    5 Pages

  25. KB 23

    5 Pages

  26. KT 170

    6 Pages

  27. KT 115

    6 Pages

  28. KT 53

    5 Pages

  29. B 28

    4 Pages

  30. Model MKF 56

    6 Pages

  31. KBF P 720

    6 Pages

  32. KBF LQC 240

    6 Pages

  33. KBF LQC 720

    7 Pages

  34. KMF 115

    6 Pages

  35. KMF 240

    6 Pages

  36. KMF 720

    6 Pages

  37. MK 53

    6 Pages

  38. MK 115

    6 Pages

  39. MK 240

    6 Pages

  40. MK 720

    6 Pages

  41. MKF 115

    7 Pages

  42. MKF 240

    7 Pages

  43. MKF 720

    7 Pages

  44. MKT 115

    6 Pages

  45. MKT 240

    6 Pages

  46. MKT 720

    6 Pages

  47. MKFT 115

    7 Pages

  48. MKFT 240

    7 Pages

  49. MKFT 720

    7 Pages

  50. BINDER Service

    12 Pages

  51. BD 56

    4 Pages

  52. CB 160

    6 Pages

  53. CB 60

    6 Pages