Constant climate chambers: KBF | KBF P | KBF LQC | KMF series - 12 Pages

Add to MyMedicalExpo favorites
Constant climate chambers: KBF | KBF P | KBF LQC | KMF series

Catalog excerpts

Best conditions for your success Constant climate Always the right climate

 Open the catalog to page 1

TABLE OF CONTENTS Advantages Constant climate chambers with large temperature / humidity range – KBF Constant climate chambers with ICH-compliant light source and light dose control – KBF P, KBF LQC Constant climate chambers with expanded temperature / humidity range – KMF 2

 Open the catalog to page 2

PRECISE CLIMATE CONDITIONS FRESH WATER AND CONDENSATION MANAGEMENT FAST AND PRECISE HUMIDIFICATION HOMOGENEOUS LIGHT DISTRIBUTION Always the right climate Research and quality assurance is solely focused on the optimization and monitoring of the performance standards as well as the functions and service life of materials, products and systems. A climate chamber is expected to simulate the effects of temperature, humidity, and light on the chemical and physical behavior of the test material in a reproducible manner. With these specific requirements in mind, BINDER offers a range of constant...

 Open the catalog to page 3

Constant climate chambers | Advantages The one-stop solution Constant climate chambers from BINDER NO RISK OF ELECTROCHEMICAL CORROSION • The inner chamber and all fixtures are made entirely from stainless steel FLEXIBLE FRESH WATER AND CONDENSATION MANAGEMENT • Standard connection to the domestic water supply • Optional external water supply set • Sewage pump integrated as standard for discharges of up to 1 m in height • Connection option for the BINDER Pure Aqua Service in order to provide the required water quality EXCEPTIONAL AMBIENT TEMPERATURE DISTRIBUTION • BINDER APT.lineTM...

 Open the catalog to page 4

Advantages | Constant climate chambers ACCURATE HUMIDITY CONTROL • Capacitive humidity sensor • Fast-reacting, hot-steam humidification with long-life steam humidification system • Patented humidification system • Self-cleaning (KBF P, KBF LQC) CONDENSATION-FREE OPERATION • Even at high temperatures and humidity levels thanks to an extended climate range of up to 98 % RH. (KMF) HOMOGENEOUS LIGHT DISTRIBUTION OVER THE ENTIRE USABLE SPACE (KBF P, KBF LQC) • ICH-Q1 B Option 2 compliant light spectrum with BINDER Synergy Light™ • Variable positionable and removable illumination cassettes...

 Open the catalog to page 5

Constant climate chambers with large temperature / humidity range | KBF KBF series The long-term, constant climate conditions of BINDER constant climate chambers are impressive. The KBF series is ideal for standard-compliant work according to ICH guidelines. As an inexpensive alternative to using multiple types of climate chambers, the BINDER constant climate chambers can be used for a number of applications. Standard features • • • • • • • • • • Temperature range: 0 to 70 °C Humidity range: 10 to 80 % RH APT.line™ preheating chamber technology Humidity regulation with capacitive humidity...

 Open the catalog to page 6

KBF | Constant climate chambers with large temperature / humidity range TECHNICAL DATA KBF SERIES Description Basic data Technical data: Temperature Temperature range [°C] Temperature variation at 40 °C [± K] Recovery time after door was opened for 30 sec. at 40 °C and 75 % RH [min] Technical data: Climate We reserve the right to alter technical specifications at any time. A: Guaranteed condensation-free range A: Garantiert kondensationsfreier Bereich B: Time-limited operation (max. 24 hours) B: Zeitliche ei

 Open the catalog to page 7

Constant climate chambers with ICH-compliant light source and light dose control | KBF P | KBF LQC KBF P | KBF LQC series BINDER's constant climate chambers with ICH-compliant illumination provide impressive long-term constant climate and illumination values. With the patented Light Quantum ControlTM (LQC), they offer a complete and reliable solution for photostability testing in one chamber. Temperature range with light: 10 to 60 °C Humidity range: 10 to 75 % RH APT.line™ preheating chamber technology Model 240/720: 2/3 positionable illumination cassettes with ICH-compliant UVA/visible...

 Open the catalog to page 8

KBF P, KBF LQC | Constant climate chambers with ICH-compliant light source and light dose control TECHNICAL DATA KBF P, KBF LQC SERIES Description ICH-compliant illumination (visible light) [lx] Basic data Technical data: Temperature Temperature range without illumination cassettes [°C] Temperature range with illumination cassettes with illumination [°C] Recovery time after door was opened for 30 sec. at 40 °C and 75 % RH with illumination [min] Technical data: Climate Temperature range without illumination cassettes [°C] Temperature range with illumination cassettes with illumination [°C]...

 Open the catalog to page 9

Constant climate chambers with expanded temperature / humidity range | KMF KMF series BINDER's constant climate chambers with expanded temperature / humidity range ensure absolutely constant test conditions throughout the testing area during stress tests. In addition to the exceptionally broad temperature range of -10 to 100 °C, the KMF series features enormous power reserves in the humidity range of up to 98% RH. Ideal for meeting the test standards of the electronics industry as well as many other areas of application. Standard features • • • • • • • • • • Temperature range: -10 to 100 °C...

 Open the catalog to page 10

KMF | Constant climate chambers with expanded temperature / humidity range TECHNICAL DATA KMF SERIES Description Mean warm-up rate acc. to IEC 60068-3-5 [K/min] Mean cooling rate acc. to IEC 60068-3-5 [K/min] Basic data Technical data: Temperature Technical data: Climate We reserve the right to alter technical specifications at any time. KMF series TEMPERATURE-HUMIDITY CHART 100 A: Control range of temperature and relative humidity A: Regelbereich von Temperatur und relativer Feuchtigkeit B: Discontinuous areaBereichcontinuous operation) B: Diskontinuierlicher (no (kein Dauerbetrieb) C:...

 Open the catalog to page 11

Representative Office for CIS Moscow, Russia BINDER Asia Pacific (Hong Kong) Ltd. Kowloon, Hong Kong, P.R. China BINDER Environmental Testing Equipment (Shanghai) Co., Ltd. Shanghai , P.R.China 7002-0271 2_V08-2015 Deviations from the figures, information, and technical data are reserved. BINDER GmbH Tuttlingen, Germany

 Open the catalog to page 12

All BINDER GmbH catalogs and technical brochures

  1. C 170

    5 Pages

  2. VDL 115

    5 Pages

  3. VDL 53

    5 Pages

  4. FDL 115

    5 Pages

  5. VD 23

    5 Pages

  6. VD 53

    5 Pages

  7. VD 115

    5 Pages

  8. VDL 23

    5 Pages

  9. M 115

    6 Pages

  10. M 240

    5 Pages

  11. FP 115

    6 Pages

  12. FP 53

    6 Pages

  13. E 28

    4 Pages

  14. UF V 700

    7 Pages

  15. UF V 500

    7 Pages

  16. KBWF 720

    6 Pages

  17. KBWF 240

    6 Pages

  18. KBW 720

    6 Pages

  19. KBW 400

    6 Pages

  20. KBW 240

    6 Pages

  21. KB 720

    5 Pages

  22. KB 400

    6 Pages

  23. KB 240

    5 Pages

  24. KB 53

    5 Pages

  25. KB 23

    5 Pages

  26. KT 170

    6 Pages

  27. KT 115

    6 Pages

  28. KT 53

    5 Pages

  29. B 28

    4 Pages

  30. Model MKF 56

    6 Pages

  31. KBF P 720

    6 Pages

  32. KBF LQC 240

    6 Pages

  33. KBF LQC 720

    7 Pages

  34. KMF 115

    6 Pages

  35. KMF 240

    6 Pages

  36. KMF 720

    6 Pages

  37. MK 53

    6 Pages

  38. MK 115

    6 Pages

  39. MK 240

    6 Pages

  40. MK 720

    6 Pages

  41. MKF 115

    7 Pages

  42. MKF 240

    7 Pages

  43. MKF 720

    7 Pages

  44. MKT 115

    6 Pages

  45. MKT 240

    6 Pages

  46. MKT 720

    6 Pages

  47. MKFT 115

    7 Pages

  48. MKFT 240

    7 Pages

  49. MKFT 720

    7 Pages

  50. BINDER Service

    12 Pages

  51. BD 56

    4 Pages

  52. CB 220

    6 Pages

  53. CB 160

    6 Pages

  54. CB 60

    6 Pages