1. Catalogs
  2. BINDER GmbH
  3. Drying and heating chambers

Drying and heating chambers

Drying and heating chambers
1 / 50 PagesView full catalog

Drying and heating chambers

Product catalog summary
Overview of Drying and Heating Chambers Avantgarde.Line
BINDER's Avantgarde.Line drying and heating chambers are designed for high-quality performance, emphasizing energy efficiency and temperature accuracy. Equipped with APT.line™ technology, these chambers ensure precise temperature control and uniform distribution.
Advantages
  • Easy data logging via USB or Ethernet.
  • High energy efficiency with minimal installation requirements.
  • Intuitive handling with a modern controller and LCD display.
  • Homogeneous temperature distribution for excellent accuracy.
Series ED Avantgarde.Line
This series features natural convection, suitable for drying and sterilization tasks up to 300°C. Key benefits include energy efficiency, temperature accuracy, and a USB connection for data recording. Models vary in interior volumes and offer features like stackability and ergonomic design.
Technical Specifications
  • Temperature range: +5°C above ambient to 300°C.
  • Energy consumption up to 30% lower than conventional units.
  • Available sizes range from 57L to 743L.
Optional Equipment
  • Access ports for external instruments.
  • Viewing windows and interior lighting.
  • HEPA air filters and various rack options.
Series FD Avantgarde.Line
Designed for fast drying and sterilization with forced convection, this series ensures quick dynamics and powerful performance. It includes a more powerful fan for faster processes.
Technical Specifications
  • Temperature range: +10°C above ambient to 300°C.
  • Available sizes range from 60L to 741L.
  • Improved heating-up and recovery times compared to natural convection models.
Ordering and Accessories
Both series offer a range of optional accessories and services, including calibration certificates, temperature safety devices, and various rack and shelf options. Detailed ordering information and additional options are available online.
Specifications
  • Temperature Range: +10°C above ambient to 300°C.
  • Energy Efficiency: Up to 30% lower energy consumption compared to conventional units.
  • Temperature Accuracy: High accuracy with APT.line™ technology.
  • Safety Features: Class 2 integrated independent adjustable temperature safety device with visual alarm (DIN 12880).
Models and Capacities
  • FD 56: 60L, 41kg, 70kg load capacity.
  • FD 115: 116L, 57kg, 150kg load capacity.
  • FD 260: 259L, 85kg, 270kg load capacity.
  • FD 720: 741L, 166kg, 315kg load capacity.
Key Features
  • Adjustable fan speed and enhanced time functions.
  • Electromechanical control of the exhaust air flap.
  • USB connection for data recording.
  • Stackable units up to 115 liters.
Optional Equipment
  • Access ports with silicone plugs for external measuring instruments.
  • Viewing windows with triple-glazed insulating glass and interior lighting.
  • HEPA air filters for fresh air supply.
Accessories
  • APT-COM™ software editions for data logging and management.
  • pH-neutral detergent for cleaning.
  • Qualification documents for validation support.
Technical Data
  • Interior Dimensions: Vary by model, with specific width, height, and depth measurements.
  • Performance Data: Includes temperature variation and fluctuation, heating-up time, and recovery time.
  • Electrical Data: Nominal power varies by voltage and model.
Ordering Information Detailed article numbers for each model and option are provided for easy reference.
Solid.Line Series
  • ED-S Series: Features natural convection, temperature range from +7°C to 250°C, and APT.line™ technology for homogeneous temperature distribution.
  • FD-S Series: Features forced convection, temperature range from +10°C to 250°C, and similar APT.line™ technology.
Technical Data
  • ED-S 56 and 115 Models: Interior volumes of 62L and 118L, respectively, with temperature variation and fluctuation details provided.
  • FD-S 56 and 115 Models: Interior volumes of 55L and 106L, respectively, with detailed performance data.
Advantages
  • Easy operation with digital display and adjustable exhaust air flap.
  • Excellent temperature accuracy with APT.line™ technology.
See more

Catalog excerpts

Drying and heating chambers-1

Best conditions for your success Drying and heating chambers Avantgarde.Line

 Open the catalog to page 1
Drying and heating chambers-3

Drying and heating chambers Avantgarde.Line Series ED Avantgarde.Line Page 6 Series FD Avantgarde.Line Page 12 Series FED Avantgarde.Line Page 19 Series FP Avantgarde.Line Page 26 Series M Avantgarde.Line Page 31 BINDER drying chambers with natural convection or forced convection are renowned for their high quality and reliability. Thanks to their extensive redevelopment, these all-rounders are now even more firmly focused on addressing the requirements involved in drying or heating samples. What's more, in addition to the best energy efficiency on the market and convenient operation, the latest...

 Open the catalog to page 3
Drying and heating chambers-4

| Drying and heating chambers Avantgarde.Line

 Open the catalog to page 4
Drying and heating chambers-5

Drying and heating chambers Avantgarde.Line | Advantages at a glance EASY DATA LOGGING EASY, INTUITIVE HANDLING Our state-of-the-art controller with LCD display, excellent readability, alphanumeric display, and various functions provide a user friendly interface. Choice of languages as standard: English, German, and French. BEST ENERGY EFFICIENCY AND LOW INSTALLATION REQUIREMENTS thanks to low heat dissipation and an optimized heating system. COMPLETELY HOMOGENEOUS TEMPERATURE DISTRIBUTION This feature provides excellent spatial and temporal temperature accuracy with the all-new generation of...

 Open the catalog to page 5
Drying and heating chambers-6

Series ED Avantgarde.Line | Drying and heating chambers Avantgarde.Line BENEFITS MAIN FEATURES • Best energy efficiency on the market • Excellent temporal and spatial temperature accuracy • USB connection for recording data • Temperature range: +5 °C above ambient temperature to +300 °C • Up to 30% lower energy consumption compared to conventional units on the market • High temperature accuracy thanks to APT.line™ technology • Natural convection • Controller with LCD display • Electromechanical control of the exhaust air flap • Units up to 115 liters are stackable • Class 2 integrated independent...

 Open the catalog to page 6
Drying and heating chambers-7

Drying and heating chambers Avantgarde.Line | Series ED Avantgarde.Line OPTIONAL EQUIPMENT Access port with silicone plug For introducing external measuring instruments. Large selection of different diameters Viewing window and interior lighting Viewing window in the door with a triple-glazed insulating glass and interior lighting for Shelf racks Perforated shelves or shelf racks, chrome-plated or made from stainless steel. and positions (left, right, or top) easy visibility of the samples. Particle filter on fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, > 99.995%...

 Open the catalog to page 7
Drying and heating chambers-8

TECHNICAL DATA Net weight of the unit (empty) [kg] 42 Wall clearance back [mm] 160 Wall clearance sidewise [mm] 100 Internal Dimensions Housing dimensions not incl. fittings and connections Width net [mm] 560 Performance Data Temperature Temperature range +5 °C above ambient temperature to [°C] 300 Recovery time after 30 seconds door open at 150 °C [min] 19 Tabellen Electrical data Nominal power (version 120 V) [kW] 1.15 Nominal power (version 230 V) [kW] 1.05 Nominal power (version 240 V) [kW] - Nominal power (version 400 V) [kW] - Number of shelves (std./max.) 2/4 Further details: Go to www.binder-worid.com...

 Open the catalog to page 8
Drying and heating chambers-9

Drying and heating chambers Avantgarde.Line | Series ED Avantgarde.Line DIMENSIONS incl. fittings and connections [mm] ED 56 ORDERING INFORMATION OPTIONS Designation Access port with silicone plug Alarm function for overheating Switchable acoustic alarm, with adjustable limit value on the independent temperature safety device for temperature values (output not adjustable) Calibration certificate, expa

 Open the catalog to page 9
Drying and heating chambers-10

Series ED Avantgarde.Line | Drying and heating chambers Avantgarde.Line for temperature, measurement in center of chamber at specified temperature temperature measurement incl. certificate and 27 measuring points at specified temperature temperature measurement incl. certificate, 15- 18 measuring points at specified temperature temperature measurement incl. certificate, 9 measuring points at specified temperature Class 3.1 independent temperature safety device with visual alarm (DIN 12880) Calibration certificate, temperature Door gasket Door lock lockable door handle Ethernet interface for Multi...

 Open the catalog to page 10
Drying and heating chambers-11

for working under GLP-compliant conditions. Measured values are APT-COM™ 4 GLP-Editi- documented in a tamper-proof way in line with the requirements of FDA on Regulation 21 CFR 11. convenient unit and user management built on the BASIC edition. Suitable for networking up to 100 units. version 4, PROFESSIONAL edition • Ethernet interface for Multi Management Software APT-COM™ • • • - 8012-1645 pH-neutral detergent concentrated, for gentle remove of residual contaminants; 1 kg • • • • 8012-2250 IQ/OQ documents - supporting documents for validation performed by customers, consisting of: IQ/OQ checklists...

 Open the catalog to page 11
Drying and heating chambers-12

Series FD Avantgarde.Line | Drying and heating chambers Avantgarde.Line • Best energy efficiency on the market • Excellent temporal and spatial temperature accuracy • USB connection for recording data MAIN FEATURES • Temperature range: +10 °C above ambient temperature to +300 °C • High temperature accuracy thanks to APT.line™ technology • Forced convection • Controller with LCD display • Electromechanical control of the exhaust air flap • Class 2 independent temperature safety device (DIN 12880) with visual temperature alarm • Ergonomic handle design • USB port for recording data Model Interior...

 Open the catalog to page 12
Drying and heating chambers-13

Drying and heating chambers Avantgarde.Line | Series FD Avantgarde.Line OPTIONAL EQUIPMENT Access port with silicone plug For introducing external measuring instruments. Large selection of different diameters Viewing window and interior lighting Viewing window in the door with a triple-glazed insulating glass and interior lighting for Shelf racks Perforated shelves or shelf racks, chrome-plated or made from stainless steel. and positions (left, right, or top) easy visibility of the samples. Particle filter on fresh air supply for unit; filter classification H14 (acc. to. EN 1822-1:2009, > 99.995%...

 Open the catalog to page 13
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.