KBF P 720 - 6 Pages

Add to MyMedicalExpo favorites
KBF P 720

Catalog excerpts

Data Sheet Model KBF P 720 Model KBF P 720 | Constant climate chambers with ICH-compliant light source BENEFITS • Homogeneous climate conditions thanks to APT.line™ technology • Automatic water and wastewater management • Pressure humidification with fast response times • Variable position and removable illumination cassettes • ICH-compliant illumination for long-term stable test conditions • Precise photometry with 3D ball-type sensors at the sample MAIN FEATURES • Temperature range: 0 °C to 70 °C • Tightly-sealed inner door made of tempered safety glass • Temperature range with light: 10 °C to 60 °C • 3 stainless steel racks • Access port with silicone plug, 30 mm, left • 3 positionable illumination cassettes with ICH-compliant UV/Vis light • 4 stable castors, two with brakes • Class 3.1 independent temperature safety device (DIN 12880) with visual • APT.line™ preheating chamber technology and audible temperature alarm • Humidity regulation with capacitive humidity sensor and vapor humidification • Computer interface: Ethernet • Door heating • Inner chamber made of stainless steel • Controller with time-segment programming ORDERING INFORMATION Interior volume [L] Option model BINDER Data Sheet | As of: 04.03.2016 Technica

 Open the catalog to page 1

Data Sheet Model KBF P 720 TECHNICAL DATA Description Article Number Temperature range without illumination cassettes [°C] Temperature range with illumination cassettes, with illumination [°C] Max. heat compensation at 40 °C with illumination [W] Recovery time after 30 seconds door open at 25 °C and 60 % RH with illumination [min] Recovery time after 30 seconds door open at 40 °C and 75 % RH with illumination [min] Temperature range without illumination cassettes [°C] Temperature range with illumination cassettes, with illumination [°C] Temperature uniformity with illumination at 25 °C and...

 Open the catalog to page 2

Data Sheet Model KBF P 720 Climate chart OPTIONS AND ACCESSORIES Designation Access port with silicone plug Alarm output, zerovoltage for temperature (±2 °C) and humidity (±5 % RH), accessible via 6-pin DIN socket (max. 24 V - 2.5 A), with audible signal that can be switched off for temperature and humidity values (output not adjustable) BINDER Pure Aqua Service system for preparation or complete desalination of tap water, containing single-use cartridge, hoses and measuring device BINDER Pure Aqua Service, accessories Single-use, replacement cartridge for BINDER Pure Aqua System...

 Open the catalog to page 3

Data Sheet Model KBF P 720 T 220: temperature logging from -90 °C to 220 °C TH 70/70: temperature and humidity logging from -40 °C to 70 °C and 0 % to 100 % RH and additional combination sensor for recording environmental conditions TH 70: temperature and humidity logging from -40 °C to 70 °C and 0 % to 100 % RH Data Logger Kit, software LOG ANALYZE software kit, configuration and evaluation software for all BINDER Data Logger Kits (incl. USB data cable) Door lock lockable door handle ICH illumination cassette, accessories replacement fluorescent tubes for one illumination cassette (set of...

 Open the catalog to page 4

Data Sheet Model KBF P 720 SERVICES Designation and set up of unit at operating location, connect to existing connections unit function instructions for operation and programming of the controller Execution of equipment inspection according to maintenance plan Calibration temperature and humidity including certificate, one measuring point in center of chamber at 25 °C / 60 % RH or at specified values Light photometry including certificate, 25 measuring points on 3 measurement levels, intensity measurements for visible light and UVA, as well as spectral distribution (qualitative spectral...

 Open the catalog to page 5

Data Sheet Model KBF P 720 Condensation may occur in the area around the access port. Access ports may be placed in custom locations for an additional charge. UL mark is not granted when this option is used. Heat resistant only to max. 200 °C. Only available on units rated for 230 V. Attention: The pump is delivered separately. The electric connection for the pump (230 V/1~/50 Hz) must be carried out by an authorized electrician. Heating-up time may increase as a result of the lower heat conductivity. The additional heat input may affect the temperature behavior. The pump (packaged...

 Open the catalog to page 6

All BINDER GmbH catalogs and technical brochures

  1. C 170

    5 Pages

  2. VDL 115

    5 Pages

  3. VDL 53

    5 Pages

  4. FDL 115

    5 Pages

  5. VD 23

    5 Pages

  6. VD 53

    5 Pages

  7. VD 115

    5 Pages

  8. VDL 23

    5 Pages

  9. M 115

    6 Pages

  10. M 240

    5 Pages

  11. FP 115

    6 Pages

  12. FP 53

    6 Pages

  13. E 28

    4 Pages

  14. UF V 700

    7 Pages

  15. UF V 500

    7 Pages

  16. KBWF 720

    6 Pages

  17. KBWF 240

    6 Pages

  18. KBW 720

    6 Pages

  19. KBW 400

    6 Pages

  20. KBW 240

    6 Pages

  21. KB 720

    5 Pages

  22. KB 400

    6 Pages

  23. KB 240

    5 Pages

  24. KB 53

    5 Pages

  25. KB 23

    5 Pages

  26. KT 170

    6 Pages

  27. KT 115

    6 Pages

  28. KT 53

    5 Pages

  29. B 28

    4 Pages

  30. Model MKF 56

    6 Pages

  31. KBF LQC 240

    6 Pages

  32. KBF LQC 720

    7 Pages

  33. KMF 115

    6 Pages

  34. KMF 240

    6 Pages

  35. KMF 720

    6 Pages

  36. MK 53

    6 Pages

  37. MK 115

    6 Pages

  38. MK 240

    6 Pages

  39. MK 720

    6 Pages

  40. MKF 115

    7 Pages

  41. MKF 240

    7 Pages

  42. MKF 720

    7 Pages

  43. MKT 115

    6 Pages

  44. MKT 240

    6 Pages

  45. MKT 720

    6 Pages

  46. MKFT 115

    7 Pages

  47. MKFT 240

    7 Pages

  48. MKFT 720

    7 Pages

  49. BINDER Service

    12 Pages

  50. BD 56

    4 Pages

  51. CB 220

    6 Pages

  52. CB 160

    6 Pages

  53. CB 60

    6 Pages