Data Sheet Model KMF 720 Model KMF 7201 Constant climate chambers with expanded temperature / humidity range • Homogeneous climate conditions thanks to APT.line™ technology • Automatic water and wastewater management • Humidification with fast response times • Wide humidity range up to 98 % RH • Long-term stress testing, e.g. at 85 °C / 85 % RH MAIN FEATURES • APT.line™ preheating chamber technology • Humidity regulation with capacitive humidity sensor and vapor • Inner chamber made of stainless steel • BINDER APT-COM™ 3 Basic Edition communication software • Controller with time-segment programming • Tightly-sealed inner door made of tempered safety glass • 1 stainless steel rack • Access port with silicone plug, 30 mm, left • Class 3.1 independent temperature safety device (DIN 12880) with visual and audible temperature alarm • Computer interface: Ethernet • Door heating ORDERING INFORMATION Option model TECHNICAL DATA Performance Data Temperature Average heating-up rate accordingto IEC 60068-3-5 [K/min] 0.7 0.7 Average cooling down time accordingto IEC 60068-3-5 [K/min] 0.4 0.4 BINDER Data Sheet | As of: 04.03.2016 Technical specifications are subject to change.

 Open the catalog to page 1

Data Sheet Model KMF 720 Article Number Temperature uniformity depending on setpoint [± K] Temperature fluctuation depending on setpoint [± K] Humidity fluctuation depending on setpoint Dew point temperature range [°C] Phase (Nominal voltage) Wall clearance back [mm] Wall clearance sidewise [mm] Inner doors Unit doors Net weight of the unit (empty) [kg] Performance Data Climate Electrical data Measures - Outer dimensions Measures - Doors Measures - Internal Dimensions Environment-specific data BINDER Data Sheet | As of: 04.03.2016 Technical specification

 Open the catalog to page 2

Data Sheet Model KMF 720 A; Guaranteed condenaatian-free range B: Time-limited operation (max. 24 hours) C: Condensation inlhe mnerchamber may be possible Climate chart Cooling down rate Access port with silicone Alarm output, zero- for temperature (±2 °C) and humidity (±5 % RH), accessible via 6-pin DIN socket (max. 24 V - 2.5 A), with audible signal for temperature and humidity values (output not adjustable) k Notes > See last page BINDER Data Sheet | As of: 04.03.2016 Technical specifications are subject to change.

 Open the catalog to page 3

Data Sheet Model KMF 720 BINDER Pure Aqua Service system for preparation or complete desalination of tap water, containing single-use cartridge, hoses and measuring device BINDER Pure Aqua Service, accessories Single-use, replacement cartridge for BINDER Pure Aqua System Calibration certificate, expanded for temperature and humidity, each additional measurement at additional points or sets of values temperature measurement incl. certificate and 27 measuring points at specified temperature temperature measurement incl. certificate, 15- 18 measuring points at specified temperature temperature...

 Open the catalog to page 4

Data Sheet Model KMF 720 version 3, BASIC edition version 3, STANDARD edition and set up of unit at operating location, connect to existing connections unit function instructions for operation and programming of the controller Execution of equipment inspection according to maintenance plan Calibration temperature and humidity including certificate, one measuring point in center of chamber at 25 °C / 60 % RH or at specified values Temperature and humidity measurement according to DIN12880 including certificate (27 temperature measuring points and 1 humidity measuring point, at 25 °C / 60 %...

 Open the catalog to page 5

Data Sheet Model KMF 720 Condensation may occur in the area around the access port. Access ports may be placed in custom locations for an additional charge. UL mark is not granted when this option is used. Heat resistant only to max. 200 °C. Only available on units rated for 230 V. Attention: The pump is delivered separately. The electric connection for the pump (230 V/1~/50 Hz) must be carried out by an authorized electrician. Heating-up time may increase as a result of the lower heat conductivity. The additional heat input may affect the temperature behavior. The pump (packaged...

 Open the catalog to page 6

All BINDER GmbH catalogs and technical brochures

  1. C 170

    5 Pages

  2. VDL 115

    5 Pages

  3. VDL 53

    5 Pages

  4. FDL 115

    5 Pages

  5. VD 23

    5 Pages

  6. VD 53

    5 Pages

  7. VD 115

    5 Pages

  8. VDL 23

    5 Pages

  9. M 115

    6 Pages

  10. M 240

    5 Pages

  11. FP 115

    6 Pages

  12. FP 53

    6 Pages

  13. E 28

    4 Pages

  14. UF V 700

    7 Pages

  15. UF V 500

    7 Pages

  16. KBWF 720

    6 Pages

  17. KBWF 240

    6 Pages

  18. KBW 720

    6 Pages

  19. KBW 400

    6 Pages

  20. KBW 240

    6 Pages

  21. KB 720

    5 Pages

  22. KB 400

    6 Pages

  23. KB 240

    5 Pages

  24. KB 53

    5 Pages

  25. KB 23

    5 Pages

  26. KT 170

    6 Pages

  27. KT 115

    6 Pages

  28. KT 53

    5 Pages

  29. B 28

    4 Pages

  30. Model MKF 56

    6 Pages

  31. KBF P 720

    6 Pages

  32. KBF LQC 240

    6 Pages

  33. KBF LQC 720

    7 Pages

  34. KMF 115

    6 Pages

  35. KMF 240

    6 Pages

  36. MK 53

    6 Pages

  37. MK 115

    6 Pages

  38. MK 240

    6 Pages

  39. MK 720

    6 Pages

  40. MKF 115

    7 Pages

  41. MKF 240

    7 Pages

  42. MKF 720

    7 Pages

  43. MKT 115

    6 Pages

  44. MKT 240

    6 Pages

  45. MKT 720

    6 Pages

  46. MKFT 115

    7 Pages

  47. MKFT 240

    7 Pages

  48. MKFT 720

    7 Pages

  49. BINDER Service

    12 Pages

  50. BD 56

    4 Pages

  51. CB 220

    6 Pages

  52. CB 160

    6 Pages

  53. CB 60

    6 Pages