MK 115 - 6 Pages

Add to MyMedicalExpo favorites
MK 115

Catalog excerpts

Data Sheet Model MK 115 Model MK 115 | Dynamic climate chambers for rapid temperature changes BENEFITS • Homogeneous climate conditions thanks to APT.line™ technology • Comprehensive programming and data acquisition • Large heated viewing window MAIN FEATURES • Temperature range: -40 °C to 180 °C • Adjustable ramp function • APT.line™ preheating chamber technology • Integrated chart recorder • Programmable condensation protection for test material • Real-time clock • Heated viewing window with LED interior lighting • Door heating • BINDER APT-COM™ 3 Basic Edition communication software • 1 stainless steel rack • Troubleshooting system with visual and audible alarms • BINDER test confirmation • Controller with time-segment programming • Inner chamber made of stainless steel • Access port with silicone plug, 50 mm, left • Class 2 independent adjustable temperature safety device (DIN 12880) • Thermal insulation using PUR foam with visual alarm • 4 castors, two with brakes • Cooling with compressor cooling unit • Computer interface: Ethernet • 230 V power socket on the right-side control panel • Display via color LCD monitor ORDERING INFORMATION Interior volume [L] Option model with voltage and frequency converter TECHNICAL DATA Description Article Number Performance Data Temperature Temperature range [°C] BINDER Data Sheet | As of: 04.0

 Open the catalog to page 1

Data Sheet Model MK 115 Article Number Temperature uniformity depending on setpoint [± K] Temperature fluctuation depending on setpoint [± K] Average heating-up rate according to IEC 60068-3-5 [K/min] Average cooling down time according to IEC 60068-3-5 [K/min] Phase (Nominal voltage) Wall clearance back [mm] Wall clearance sidewise [mm] Viewing window width [mm] Viewing window height [mm] Net weight of the unit (empty) [kg] Electrical data Measures - Outer dimensions Measures - Doors Unit doors Measures - Internal Dimensions Environment-specific data Sound-pressure level [dB(A)] BINDER...

 Open the catalog to page 2

Data Sheet Model MK115 Heat compensation chart Cooling down rate Designation Description * Art.-No. Access port notch-type access port in door, 100 x 35 mm - 8012-0708 Access port with silicone * Notes > See last page for temperature values (output not adjustable) - 8012-0517 BINDER Data Sheet | As of: 04.03.2016 Technical specifications are subject to change.

 Open the catalog to page 3

Data Sheet Model MK 115 Calibration certificate, expanded each measurement at additional measuring point or testing temperature for temperature, measurement in center of chamber at specified temperature temperature measurement incl. certificate and 27 measuring points at specified temperature temperature measurement incl. certificate, 15- 18 measuring points at specified temperature temperature measurement incl. certificate, 9 measuring points at specified temperature Converter, voltage and frequency to operate the device at a nominal voltage of 480 V 3 ph 60 Hz, 32 A T 220: temperature...

 Open the catalog to page 4

Data Sheet Model MK 115 SERVICES Designation and set up of unit at operating location, connect to existing connections unit function instructions for operation and programming of the controller Executive of equipment inspection according to maintenance plan Calibration temperature including certificate, one measuring point in center of chamber at specified temperature Temperature measurement 18 measuring points including certificate, 18 measuring points at specified temperature Temperature measurement 27 measuring points including certificate, 27 measuring points at specified temperature...

 Open the catalog to page 5

Data Sheet Model MK 115 Condensation may occur in the area around the access port. Access ports may be placed in custom locations for an additional charge. UL mark is not granted when this option is used. Heat resistant only to max. 200 °C. Only available on units rated for 230 V. Attention: The pump is delivered separately. The electric connection for the pump (230 V/1~/50 Hz) must be carried out by an authorized electrician. Heating-up time may increase as a result of the lower heat conductivity. The additional heat input may affect the temperature behavior. The pump (packaged separately)...

 Open the catalog to page 6

All BINDER GmbH catalogs and technical brochures

  1. C 170

    5 Pages

  2. VDL 115

    5 Pages

  3. VDL 53

    5 Pages

  4. FDL 115

    5 Pages

  5. VD 23

    5 Pages

  6. VD 53

    5 Pages

  7. VD 115

    5 Pages

  8. VDL 23

    5 Pages

  9. M 115

    6 Pages

  10. M 240

    5 Pages

  11. FP 115

    6 Pages

  12. FP 53

    6 Pages

  13. E 28

    4 Pages

  14. UF V 700

    7 Pages

  15. UF V 500

    7 Pages

  16. KBWF 720

    6 Pages

  17. KBWF 240

    6 Pages

  18. KBW 720

    6 Pages

  19. KBW 400

    6 Pages

  20. KBW 240

    6 Pages

  21. KB 720

    5 Pages

  22. KB 400

    6 Pages

  23. KB 240

    5 Pages

  24. KB 53

    5 Pages

  25. KB 23

    5 Pages

  26. KT 170

    6 Pages

  27. KT 115

    6 Pages

  28. KT 53

    5 Pages

  29. B 28

    4 Pages

  30. Model MKF 56

    6 Pages

  31. KBF P 720

    6 Pages

  32. KBF LQC 240

    6 Pages

  33. KBF LQC 720

    7 Pages

  34. KMF 115

    6 Pages

  35. KMF 240

    6 Pages

  36. KMF 720

    6 Pages

  37. MK 53

    6 Pages

  38. MK 240

    6 Pages

  39. MK 720

    6 Pages

  40. MKF 115

    7 Pages

  41. MKF 240

    7 Pages

  42. MKF 720

    7 Pages

  43. MKT 115

    6 Pages

  44. MKT 240

    6 Pages

  45. MKT 720

    6 Pages

  46. MKFT 115

    7 Pages

  47. MKFT 240

    7 Pages

  48. MKFT 720

    7 Pages

  49. BINDER Service

    12 Pages

  50. BD 56

    4 Pages

  51. CB 220

    6 Pages

  52. CB 160

    6 Pages

  53. CB 60

    6 Pages