MKT 240 - 6 Pages

Add to MyMedicalExpo favorites
MKT 240

Catalog excerpts

Data Sheet Model MKT 240 Model MKT 240 | Dynamic climate chambers for rapid temperature changes with extended low temperature range BENEFITS • Homogeneous climate conditions thanks to APT.line™ technology • Comprehensive programming and data acquisition • Large heated viewing window MAIN FEATURES • Temperature range: -70 °C to 180 °C • Adjustable ramp function • 4 zero-voltage relay contacts that can be activated via MCS controller • Integrated chart recorder • APT.line™ preheating chamber technology • Real-time clock • Programmable condensation protection for test material • Door heating • Heated viewing window with LED interior lighting • 1 stainless steel rack • BINDER APT-COM™ 3 Basic Edition communication software • BINDER test confirmation • Troubleshooting system with visual and audible alarms • Inner chamber made of stainless steel • Controller with time-segment programming • Access port with silicone plug: 50 mm, left • Thermal insulation using PUR foam • Class 2 independent adjustable temperature safety device (DIN 12880) with visual alarm • Cooling with cascade compressor cooling unit • 4 castors, two with brakes • Computer interface: Ethernet • 230 V power socket on the right-side control panel • Display via color LCD monitor ORDERING INFORMATION Interior volume [L] Option model with voltage and frequency converter BINDER Data Sheet | As of: 04.03.2

 Open the catalog to page 1

Data Sheet Model MKT 240 TECHNICAL DATA Performance Data Temperature Temperature uniformity depending on setpoint [± K] 0.1...1 0.1...1 Temperature fluctuation depending on setpoint [± K] 0.1...0.4 0.1...0.4 Average heating-up rate accordingto IEC 60068-3-5 [K/min] 5 5 Average cooling down time accordingto IEC 60068-3-5 [K/min] 4.2 4.2 Electrical data Phase (Nominal voltage) 3~ 3~ Measures - Outer dimensions Wall clearance back [mm] 230 230 Wall clearance sidewise [mm] 300 300 Viewing window width [mm] 508 508 Viewing window height [mm] 300 300 Measures - Doors Measures - Internal...

 Open the catalog to page 2

Data Sheet Model MKT 240 Heat compensation chart Cooling down rate Access port Access port with silicone notch-type access port in door, 100 x 35 mm for temperature values (output not adjustable) Calibration certificate, each measurement at additional measuring point or testing temperature * Notes > See last page BINDER Data Sheet | As of: 04.03.2016 Technical specifications are subject to change.

 Open the catalog to page 3

Data Sheet Model MKT 240 for temperature, measurement in center of chamber at specified temperature Calibration certificate, temperature temperature measurement incl. certificate and 27 measuring points at specified temperature temperature measurement incl. certificate, 15- 18 measuring points at specified temperature temperature measurement incl. certificate, 9 measuring points at specified temperature Converter, voltage and frequency to operate the device at a nominal voltage of 480 V 3 ph 60 Hz, 32 A T 220: temperature logging from -90 °C to 220 °C Data Logger Kit, software LOG ANALYZE...

 Open the catalog to page 4

Data Sheet Model MKT 240 SERVICES Designation and set up of unit at operating location, connect to existing connections unit function instructions for operation and programming of the controller Executive of equipment inspection according to maintenance plan Calibration temperature including certificate, one measuring point in center of chamber at specified temperature Temperature measurement 18 measuring points including certificate, 18 measuring points at specified temperature Temperature measurement 27 measuring points including certificate, 27 measuring points at specified temperature...

 Open the catalog to page 5

Data Sheet Model MKT 240 Condensation may occur in the area around the access port. Access ports may be placed in custom locations for an additional charge. UL mark is not granted when this option is used. Heat resistant only to max. 200 °C. Only available on units rated for 230 V. Attention: The pump is delivered separately. The electric connection for the pump (230 V/1~/50 Hz) must be carried out by an authorized electrician. Heating-up time may increase as a result of the lower heat conductivity. The additional heat input may affect the temperature behavior. The pump (packaged...

 Open the catalog to page 6

All BINDER GmbH catalogs and technical brochures

  1. C 170

    5 Pages

  2. VDL 115

    5 Pages

  3. VDL 53

    5 Pages

  4. FDL 115

    5 Pages

  5. VD 23

    5 Pages

  6. VD 53

    5 Pages

  7. VD 115

    5 Pages

  8. VDL 23

    5 Pages

  9. M 115

    6 Pages

  10. M 240

    5 Pages

  11. FP 115

    6 Pages

  12. FP 53

    6 Pages

  13. E 28

    4 Pages

  14. UF V 700

    7 Pages

  15. UF V 500

    7 Pages

  16. KBWF 720

    6 Pages

  17. KBWF 240

    6 Pages

  18. KBW 720

    6 Pages

  19. KBW 400

    6 Pages

  20. KBW 240

    6 Pages

  21. KB 720

    5 Pages

  22. KB 400

    6 Pages

  23. KB 240

    5 Pages

  24. KB 53

    5 Pages

  25. KB 23

    5 Pages

  26. KT 170

    6 Pages

  27. KT 115

    6 Pages

  28. KT 53

    5 Pages

  29. B 28

    4 Pages

  30. Model MKF 56

    6 Pages

  31. KBF P 720

    6 Pages

  32. KBF LQC 240

    6 Pages

  33. KBF LQC 720

    7 Pages

  34. KMF 115

    6 Pages

  35. KMF 240

    6 Pages

  36. KMF 720

    6 Pages

  37. MK 53

    6 Pages

  38. MK 115

    6 Pages

  39. MK 240

    6 Pages

  40. MK 720

    6 Pages

  41. MKF 115

    7 Pages

  42. MKF 240

    7 Pages

  43. MKF 720

    7 Pages

  44. MKT 115

    6 Pages

  45. MKT 720

    6 Pages

  46. MKFT 115

    7 Pages

  47. MKFT 240

    7 Pages

  48. MKFT 720

    7 Pages

  49. BINDER Service

    12 Pages

  50. BD 56

    4 Pages

  51. CB 220

    6 Pages

  52. CB 160

    6 Pages

  53. CB 60

    6 Pages