video corpo

Vacuum drying chambers
16Pages

{{requestButtons}}

Catalog excerpts

Vacuum drying chambers - 1

Vacuum drying chambers VD | VDL series

Open the catalog to page 1
Vacuum drying chambers - 3

Vacuum drying chambers Vacuum drying chambers Both BINDER vacuum drying chamber models enable effective drying without residue or damaging the material being dried. With their proven technological features, the excellently address the strict requirements of industrial and scientific laboratories. Samples and similar materials incorporating flammable and non-flammable solvents can be dried, depending on the individual use. The chambers use a unique safety design that, together with accustomed outstanding performance, sets the bar in terms of quality and safety.

Open the catalog to page 3
Vacuum drying chambers - 4

Product selection | Vacuum drying chambers PRODUCT SELECTION VACUUM DRYING CHAMBERS Features For flammable solvents (ATEX) Ethernet interface Ramp function Temperature dependent delayed OFF Programming option Weekly program function Real-time clock Temperature alarm, visual General data Temperature range +9 °C above ambient tempe-rature to [°C]

Open the catalog to page 4
Vacuum drying chambers - 5

Vacuum drying chambers | Advantages at a glance EXPLOSION-PROTECTED INTERIOR AUTOMATIC DRYING DETECTION thanks to the ATEX-compliant unit concept with pressure control device for heating activation at a vacuum of < 100 mbar. The unit conforms to ATEX category EX II 2/3/- G IIB T3 Gb/Gc/- X. Thanks to the program control, the second pressure drop that typically takes place at the end of drying is detected and the interior is automatically ventilated. TESTED SAFETY JACKET HEATING thanks to the shatterproof, spring-mounted safety glass panel, inert gas connection for interior flushing, and...

Open the catalog to page 5
Vacuum drying chambers - 6

Series VD | Vacuum drying chambers Series VD | for non-flammable solvents BINDER’s VD series vacuum drying chambers while deliver impressive performance through their precise temperature control and gentle drying. The patented expansion rack technology from BINDER also ensures optimal heat transfer. The shelves provide flexible placement and are easy to dry in the interior of the chamber. MAIN FEATURES • Fast, gentle drying • Optimum heat transfer through large thermal conducting plates • Safe work thanks to proven safety concept • Also option of modular complete system with vacuum pump and...

Open the catalog to page 6
Vacuum drying chambers - 7

Vacuum drying chambers | Series VD OPTIONAL EQUIPMENT Touchscreen controller Expansion racks Analogue output for temperature and pressure Universal ventilation Universal access port DN 40 Large display panel with intuitive operation, actual and set values of main process parameters are shown simultaneously on the display. In addition, the graphic chronological evaluation of process parameters is displayed. The expansion racks ensure maximum heat transfer to the items to be dried. You can choose between aluminum and stainless steel racks. For external monitoring and evaluation of process...

Open the catalog to page 7
Vacuum drying chambers - 8

Series VD | Vacuum drying chambers TECHNICAL DATA Description Measures Interior volume [L] Net weight of the unit (empty) [kg] Wall clearance back [mm] Wall clearance sidewise [mm] Internal Dimensions Width [mm] Housing dimensions not incl. fittings and connections Width net [mm] Performance Data Temperature Temperature range +9 °C above ambient temperature to [°C] Temperature variation at 100 °C [± K] Electrical data Nominal power (version 120 V) [kW] Nominal power (version 230 V) [kW] Fixtures Number of shelves (std./max.) ORDERING INFORMATION [Art. No.] Further details: Go to...

Open the catalog to page 8
Vacuum drying chambers - 9

Vacuum drying chambers | Series VD ORDERING INFORMATION OPTIONS Bezeichnung Additional universal ventilation Additional universal connection for ventilation with ambient air or inert gas. Flow limiter thread (RP"), and connection with 3/8" male thread. for temperature and pressure values (output not adjustable) Calibration certificate, expanded for temperature; for extending the measurement in center of chamber to include another test temperature Calibration certificate, pressure for digital pressure display, measurement at 100 mbar or at specified pressure (range 20 – 900 mbar) for...

Open the catalog to page 9
Vacuum drying chambers - 10

Series VD | Vacuum drying chambers Hard copy inside folder Hard copy inside folder IQ/OQ documents – supporting documents for validation performed by customers, consisting of: IQ/OQ checklists incl. calibration guide and comprehensive unit documentation; parameters: temperature, CO₂, O₂, pressure, depending on unit Qualification documents IQ/OQ/PQ documents – supporting documents for validation performed by customers, according to customer requirements, PQ section added to qualification folder IQ/OQ; parameters: temperature, CO₂, O₂ – or pressure, depending on unit Pump chamber for vacuum...

Open the catalog to page 10
Vacuum drying chambers - 11

Vacuum drying chambers | Series VDL Series VDL | for flammable solvents BINDER VDL series safety vacuum drying chambers ensure maximum safety when drying organic solvents. Explosionpro-tected unit with classification according to ATEX directive 2014/34/EU: EX II 2/3/- G IIB T3 Gb/Gc/- X. MAIN FEATURES • Temperature range: Ambient temperature +9 °C to +110 °C • ATEX conformity for units: EX II 2/3/- G IIB T3 Gb/Gc/- X • Intuitive touchscreen controller with graphical pressure and temperature display • Program-controlled drying monitoring with automatic • ventilati-on at end of process •...

Open the catalog to page 11
Vacuum drying chambers - 12

Series VDL | Vacuum drying chambers OPTIONAL EQUIPMENT Expansion racks Analogue output for temperature and pressure Universal ventilation Universal access port DN 40 The expansion racks ensure maximum heat transfer to the items to be dried. You can choose between aluminum and stainless steel racks. For external monitoring and evaluation of process parameters, option of integration into on-site systems. For the convenient selection of different ventilation types, with air or inert gas. The valves can be actuated in a targeted manner via the controller or the APT-COM Multi Management...

Open the catalog to page 12
Vacuum drying chambers - 13

Vacuum drying chambers | Series VDL TECHNICAL DATA Description Measures Interior volume [L] Net weight of the unit (empty) [kg] Wall clearance back [mm] Wall clearance sidewise [mm] Internal Dimensions Width [mm] Housing dimensions not incl. fittings and connections Width net [mm] Performance Data Temperature Temperature range +9 °C above ambient temperature to [°C] Temperature variation at 100 °C [± K] Electrical data Nominal power (version 120 V) [kW] Nominal power (version 230 V) [kW] Fixtures Number of shelves (std./max.) ORDERING INFORMATION [Art. No.] Further details: Go to...

Open the catalog to page 13

All BINDER GmbH catalogs and technical brochures