1. Catalogs
  2. BINDER GmbH
  3. Vacuum Drying Chambers

Vacuum Drying Chambers

Vacuum Drying Chambers
1 / 21 PagesView full catalog

Vacuum Drying Chambers

Product catalog summary
Overview: The document provides comprehensive details on BINDER's vacuum drying chambers, specifically the VD and VDL series, designed for effective drying of materials without residue or damage. These chambers are suitable for both flammable and non-flammable solvents and are equipped with advanced safety features and precise temperature control, making them ideal for industrial and scientific laboratories.
Key Features:
  • Explosion-Protected Interior: Complies with ATEX standards for operational safety.
  • Automatic Drying Detection: Program-controlled to detect pressure drops and ventilate automatically.
  • Tested Safety: Includes shatterproof safety glass, inert gas connection, and decoupled electronic components.
  • Jacket Heating: Patented expansion racks for optimal heat transfer and flexible placement.
Series VD:
  • Designed for non-flammable solvents with precise temperature control and gentle drying.
  • Temperature range from +9°C above ambient to +220°C.
  • Features include digital pressure and temperature display, internal data logger, and Ethernet interface.
  • Available in different sizes: VD 23, VD 56, and VD 115, with varying interior volumes and power specifications.
Optional Equipment:
  • Expansion racks available in aluminum and stainless steel.
  • Analog output for external monitoring of temperature and pressure.
  • Universal ventilation options for air or inert gas.
  • Pump modules to optimize working height and reduce noise.
Technical Data:
  • Temperature uniformity and fluctuation details provided for each model.
  • Electrical specifications and dimensions outlined for VD 23, VD 56, and VD 115.
Ordering Information: Details on power supply options, model versions, and additional accessories like calibration certificates and door gaskets.
Services: Offers maintenance contracts, warranty extensions, and calibration services to ensure optimal performance and compliance with industry standards.
Maintenance Contracts:
  • SILVER 3-year Maintenance Contract: Includes visual inspection of mechanical and electrical components, control response check, 20% discount on spare parts, testing of key functions, and calibration of one user-specified test temperature.
  • BRONZE 3-year Maintenance Contract: Similar to SILVER but without testing of key functions and calibration.
  • GOLD 3-year Maintenance Contract: Includes all SILVER services plus replacement of wear parts.
Temperature Measurement Services:
  • 9 Measuring Points: Temperature measurement with user-specified set value, includes certificate.
  • 15 Measuring Points: Similar service with more measuring points, includes certificate.
Unit Commissioning: Connection to customer-side utilities, basic function check, and brief operating instructions (excludes unpacking and setup).
Vacuum Pump Maintenance:
  • VAP 1 and VAP 2: Maintenance includes visual inspection, diaphragm, O-ring, and seal replacement, and final functional test.
Series VDL Vacuum Drying Chambers:
  • Safety Features: ATEX-compliant for drying organic solvents, explosion-protected.
  • Temperature Range: +9°C above ambient to +110°C.
  • Controller: Intuitive touchscreen with graphical display.
  • Data Logging: Internal data logger with USB export.
  • Available Sizes: VDL 23, VDL 56, VDL 115 with varying interior volumes.
Optional Equipment:
  • Touchscreen Controller: Large display with simultaneous display of process parameters.
  • Expansion Racks: Available in aluminum or stainless steel.
  • Universal Ventilation: For air or inert gas, controlled via software.
  • Pump Module: Reduces noise and protects components.
Technical Data:
  • Temperature Uniformity: Varies by model, with specific values at 100°C.
  • Vacuum Data: Leak rate and pressure fluctuation specifications.
  • Electrical Data: Nominal power and fuse specifications.
  • Dimensions and Weights: Detailed for each model.
Ordering Information: Includes model versions, power supply options, and accessories like APT-COM™ software for data management.
Services:
  • Calibration Certificates: Available for temperature and pressure.
  • Safety Tests: ATEX-specific safety systems testing.
Temperature Measurement:
  • 9 Measuring Points: Temperature measurement with nine points, user-specified set value, without certificate.
  • 15 Measuring Points: Temperature measurement with fifteen points, user-specified set value, including certificate.
Unit Commissioning: Connect the unit to customer-side connections (electricity, water, wastewater, gas). Includes basic functions check and brief operating instructions. Excludes unpacking, setup, controller instructions, programming, and installation work.
Unit Instructions: Guidance on operating principles and basic functions of the unit, including control electronics operation and programming.
VAP 5 Vacuum Pump Maintenance: Maintenance service includes visual inspection, replacement of diaphragms, O-rings, and seals, with Service Kit 8500-0160. Final functional test included.
Product Range: Includes CO₂ incubators, standard incubators, cooling incubators, growth chambers, ultralow temperature freezers, drying and heating chambers, safety drying chambers, vacuum drying chambers, constant climate chambers, dynamic climate chambers, battery test chambers, walk-in chambers, and multi-management software.
Contact Information: BINDER GmbH, Tuttlingen, Germany. Tel: +49 7462 2005 0. Email: [email protected] BINDER Inc., Bohemia, NY, USA. Tel: +1 631 224 4340. Email: [email protected] BINDER Asia Pacific (Hong Kong) Ltd., Kowloon, Hong Kong, P.R. China. Tel: +852 39070500. Email: [email protected] BINDER Environmental Testing Equipment (Shanghai) Co., Ltd., Shanghai, P.R. China. Tel: +86 21 685 808 25. Email: [email protected]
Newsletter Subscription: Subscribe to the BINDER monthly newsletter for product updates.
See more

Catalog excerpts

Vacuum Drying Chambers-1

Best conditions for your success VACUUM DRYING CHAMBERS EN

 Open the catalog to page 1
Vacuum Drying Chambers-3

Vacuum drying chambers Vacuum drying chambers Series VD Both BINDER vacuum drying chamber models enable effective drying without residue or damaging the material being dried. With their proven technological features, the excellently address the strict requirements of industrial and scientific laboratories. Samples and similar materials incorporating flammable and non-flammable solvents can be dried, depending on the individual use. The chambers use a unique safety design that, together with accustomed outstanding performance, sets the bar in terms of quality and safety.

 Open the catalog to page 3
Vacuum Drying Chambers-5

EXPLOSION-PROTECTED INTERIOR AUTOMATIC DRYING DETECTION thanks to the ATEX-compliant unit concept with pressure control device for heating activation at a vacuum of < 100 mbar. The unit conforms to ATEX category EX II 2/3/- G IIB T3 Gb/Gc/- X. Thanks to the program control, the second pressure drop that typically takes place at the end of drying is detected and the interior is automatically ventilated. TESTED SAFETY JACKET HEATING thanks to the shatterproof, spring-mounted safety glass panel, inert gas connection for interior flushing, and electronic components decoupled from the interior. optimum...

 Open the catalog to page 5
Vacuum Drying Chambers-6

Series VD | Vacuum drying chambers IMPORTANT CHARACTERISTICS Fast, gentle drying Optimum heat transfer through large thermal conducting plates Safe work thanks to proven safety concept Also option of modular complete system with vacuum pump and pump chamber Temperature range: +9°C above ambient temperature to +220 °C Controller with digital display of pressure and temperature Program-controlled drying monitoring with automatic ventilation at end of process Internal data logger, measured values can be read out in open format via USB 1 aluminum expansion rack, can be custom-positioned Inert gas...

 Open the catalog to page 6
Vacuum Drying Chambers-7

Vacuum drying chambers | Series VD OPTIONAL EQUIPMENT Expansion racks Analog output for temperature and pressure values The expansion racks ensure maximum heat transfer to the items to be dried. You can choose between aluminum and stainless steel racks. For external monitoring and evaluation of process parameters, option of integration into on-site systems. For the convenient selection of different ventilation types, with air or inert gas. The valves Universal ventilation can be actuated in a targeted manner via the controller or the APT-COM Multi Management Software. Universal access port DN...

 Open the catalog to page 7
Vacuum Drying Chambers-8

Series VD | Vacuum drying chambers TECHNICAL DATA Data Designation Option model Temperature range +9 °C above ambient temperature to 220 °C +9 °C above ambient temperature to 220 °C +9 °C above ambient temperature to 220 °C Performance Data Temperature Vacuum Data Leak rate Pressure fluctuation over time at 50 mbar Pressure fluctuation over time at 400 mbar Nominal power Phase (Nominal voltage) Vacuum connection with small flange Measuring access port with small flange Compressed air connection for pressure-encapsulation Electrical data Dimensions and weights Interior volume Net weight of the...

 Open the catalog to page 8
Vacuum Drying Chambers-9

Vacuum drying chambers | Series VD ORDERING INFORMATION Interior volume [L] Power supply - unit fuse Model version OPTIONS Designation Additional universal ventilation Additional universal connection for ventilation with ambient air or inert gas. Flow limiter thread (RP”), and connection with 3/8” male thread. for temperature and pressure values (output not adjustable) Calibration certificate, expanded for temperature; for extending the measurement in center of chamber to include another test temperature Calibration of the pressure display to a specified value, including certificate Extension...

 Open the catalog to page 9
Vacuum Drying Chambers-10

Series VD | Vacuum drying chambers Interior lighting LED light strips on the left and right in the door Temperature measurement of the specimen with flexible Pt 100 sensor and digital specimen temperature display Touchscreen controller Large display panel with intuitive operation, actual and set values of main process parameters are shown simultaneously on the display. In addition, the graphic chronological evaluation of process parameters is displayed. Universal access port Additional DN 40 small flange universal access port with blind flange, for positioning sensors or supply lines in the chamber....

 Open the catalog to page 10
Vacuum Drying Chambers-11

Pump chamber for installation of vacuum pumps, with switchable power socket. Including chemical membrane pump with a nominal air Pump chamber VD 56 with flow of 2.0 m3/hour, final pressure 7 mbar and connection kit VD VP1-vacuum pump VP1 VP2. Pump chamber for installation of vacuum pumps, with switchable Pump chamber VD 56 with power socket. Pump chamber VD 115 with vacuum pump VP1 Pump chamber for installation of vacuum pumps, with switchable power socket. Including chemical membrane pump with a nominal air flow of 2.0 m3/hour, final pressure 7 mbar and connection kit VD VP1-VP2. Pump chamber...

 Open the catalog to page 11
Vacuum Drying Chambers-12

Series VD | Vacuum drying chambers SERVICES Designation The warranty is extended by 1 year from the delivery date, wear parts are excluded BRONZE 3-year maintenance contract Maintenance service as contractually agreed, visual inspection of mechanical and electrical components, check of control response, 20% discount on spare parts Calibration of one (1) test temperature specified by the user in center of chamber, including certificate Extension of calibration of one (1) additional test temperature specified by the user in the center of the usable space, including certificate Execution of IQ/OQ...

 Open the catalog to page 12
Vacuum Drying Chambers-14

Series VDL | Vacuum drying chambers IMPORTANT CHARACTERISTICS BENEFITS Fast, gentle drying Optimum heat transfer through large thermal conducting plates Safe working thanks to ATEX-compliant safety concept Also option of modular complete system with vacuum pump and pump chamber Temperature range: +9°C above ambient temperature to +110 °C ATEX conformity for units: EX II 2/3/- G IIB T3 Gb/Gc/- X Intuitive touchscreen controller with graphical pressure and temperature display Program-controlled drying monitoring with automatic ventilation at end of process Internal data logger, measured values...

 Open the catalog to page 14
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.