59-60 5-Part Auto Hematology Analyzer Reagent
1 /1Page

59-60 5-Part Auto Hematology Analyzer Reagent

59-60 5-Part Auto Hematology Analyzer Reagent
1 /1Page

Catalog excerpts

59-60 5-Part Auto Hematology Analyzer Reagent-1

BIOBASG CHINA 5-Part Auto Hematology Analyzer Reagent 3-Part Hematology Analyzer Reagent S&KSS- Probe Cleaning Fluid II Cleaning Cleaning Fluid II Fluid Introduction: Lyse WFL-LH: used to destroy red blood cells, dissolve hemoglobin, and maintain the morphology of the cells to be analyzed before blood cell analysis, so as to facilitate cell classification and counting or hemoglobin quantitative determination. Lyse WFL-LD: used to maintain cell morphology and perform white. Diluent WFL-2: used to dilute samples and prepare cell suspensions before blood cell analysis. Diluent 10><WFL-2: used to dilute samples and prepare cell suspensions before blood cell analysis. Concentrated version of diluent WFL-2, which needs to be diluted before use. Probe Cleaning Fluid II: used to cleaning the instrument regularly. E-Z Cleaning Fluid: used to clean and rinse the injector, valve and piping system. Cleaning the instrument regularly. ©. High accuracy, dedicated machine, benchmarked against national standard substances. ©. High stability, the reagent is stored indoors away from light, the temperature is 8-30°C, the validity period is 24 months, the validity period after opening the bottle is 60 days. (D. High safety, cyanide-free formula, non-toxic and harmless, environmental protection. @. Applicable to 5-Part Auto Hematology Analyzer BH-HA630, BH-HA650. Lyse SFLv SFL-DMs SFL-TK: used to destroy red blood cells, dissolve hemoglobin, and maintain the required morphology of analyzed cells before blood cell analysis, so as to facilitate cell classification and counting or hemoglobin quantitative determination. Diluent SFL-1: used to dilute samples and prepare cell suspensions before blood cell analysis. Diluent 10><SFL-1: used to dilute samples and prepare cell suspensions before blood cell analysis. Concentrated version of diluent SFL-1: which needs to be diluted before use. Probe Cleaning Fluid II: used to cleaning the instrument regularly. E-Z Cleaning Fluid: used to clean and rinse the injector, valve and piping system. Cleaning the instrument regularly. CD. It is highly versatile and can be used in various types of three-classification blood cell analyzers. ©. It has high stability. The reagent should be stored indoors away from light at a temperature of 8-30°C. The validity period is 24 months (SFL-DM, SFL-TK is 18 months). The validity period after opening the bottle is 60 days. (D. It has high safety, cyanide-free formula, non-toxic and harmless, and protects the environment. @. SFL is applicable to 3-Part Hematology Analyzer BH-HA310. ©. SFL-DM is applicable to 3-Part Hematology Analyzer BH-HA310VET.

 Open the catalog to page 1

All Biobase catalogs and technical brochures

  1. Homogenizer

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.