Rules of Conduct:
  • Vertical Handling: Always hold the applicator vertically with the bottle opening upwards to prevent powder from entering the tube, which can bind with liquid and obstruct application.
  • Horizontal Handling: Avoid overturning or laying the applicator horizontally to prevent liquid and powder from mixing and blocking the tube.
  • Pumping Procedure: Before applying the powder, pump the tube 4-5 times to clear any liquid. Ensure the HaemoCer™ PLUS bellows bottle is securely attached during this process.
  • Rotation Caution: Do not rotate the applicator with the bottle attached to prevent powder entry into the tube.
Application Notes:
  • The HaemoCer™ Endoscopic Applicator is designed for simple use without additional handling devices. It is crucial to follow the instructions to prevent blockage.
  • The HaemoCer™ PLUS haemostatic powder absorbs water rapidly, forming a gel matrix upon contact with liquid. Avoid contact with the endoscope's moist environment to prevent blockage.
Product Information:
  • The HaemoCer™ Endoscopic Applicator allows direct application of the HaemoCer™ PLUS powder through a standard endoscope's working channel.
  • It is used to control capillary, venous, and arteriolar bleedings in the gastrointestinal tract, especially effective for seeping haemorrhages.
  • Specifications include a tube length of 2400 mm, HEPA filter, and compatibility with instrument channels of 2.8 mm and above.
Manufacturer: BioCer Entwicklungs-GmbH, Germany.
See more

Catalog excerpts

rules of conduct-1

Application notes HaemoCer™ Endoscopic Applicator needs no handling devices (air compressor etc.) and enables a simple and uncomplicated use. To ensure this it is important to follow the steps described in the instruction for use. HaemoCer™ PLUS haemostatic powder consists of hygroscopic particles that rapidly absorb water from the blood and hence initiate a dehydration process. In contact to liquid, the haemostatic powder immediately forms a gel matrix. An endoscopy is performed in a moist environment and contact with the HaemoCer ™ PLUS haemostatic powder in the endoscope is to be avoided. To prevent blockage during preparation of the HaemoCer ™ Endoscopic Applicator, the following application notes should be observed: When preparing the applicator, always hold it vertically, with the bottle opening pointing upwards. Horizontal Do not overturn the applicator with the HaemoCer™ PLUS bellows bottle, hold it horizontally or lay it down. If powder gets into the tube before use, it binds liquid and a powder application is no longer possible. (Laying the applicator down, e.g. onto an operating table, also makes powder get into the tube and shall be avoided as well) After inserting the applicator into the endoscope and before applying the powder, the tube has to be pumped free 4-5 times. It is obligatory that the HaemoCer™ PLUS bellows bottle must be screwed on during this process. Again, do not turn the applicator with the screwed-on bottle or hold it horizontally, making sure no powder can enter the tube. Pumping is used to remove liquid that has entered the tube. This prevents powder and liquid/ moisture from coming together and blocking the tube during the app

 Open the catalog to page 1
rules of conduct-2

Endoscopic Application of Haemostatic Powder The innovative HaemoCer™ Endoscopic Applicator enables the direct application of HaemoCer™ PLUS resorbable powder through the working channel of a standard endoscope. HEPA filter (High Efficiency Particulate Air) The application tube is inserted through the instrument channel and positioned to the bleeding. The compressed air flow generated by the pump ball transports the powder directly to the bleeding site. For upper and lower gastrointestinal bleedings This system serves as a complementary haemostatic device to control capillary, venous and arteriolar...

 Open the catalog to page 2
*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.