2015 Product Catalog
28Pages

{{requestButtons}}

Catalog excerpts

2015 Product Catalog - 2

Intuitive standardization. Prep. Freeze. Transport. Store. Thaw.

Open the catalog to page 2
2015 Product Catalog - 3

Controlled-rate, alcohol-free cell freezing containers Page 3 - 6 ThawSTAR™ Automated cell thawing system Page 7 - 9 BioT™ Temperature stability systems Page 10 - 12 CoolBox™ Ice-free cooling and freezing systems Page 13 - 16 Thermo-conductive tube modules Page 17 - 20 Thermo-conductive plate modules Page 21 ThermalTray™ Thermo-conductive platforms Page 22

Open the catalog to page 3
2015 Product Catalog - 4

Controlled-Rate, Alcohol-Free Cell Freezing CoolCell® alcohol-free cell freezing containers ensure standardized controlled-rate -1oC/minute cell freezing in a -80oC freezer - without alcohol or any fluids. Proven for use with a variety of cell types including stem cells, primary cells, PBMC cell lines, insect cells, yeast and others. The patentpending CoolCell technology utilizes a thermo-conductive alloy core and highly-insulative outer material to control the rate of heat removal and provide reproducible cell cryopreservation. CoolCell units are easy to use and deliver comparable results...

Open the catalog to page 4
2015 Product Catalog - 5

CoolCell Reproducibility CoolCell Protocols Cryopreservation and Thawing of Cells Wayne M. Yokoyama, Maria L. Thompson, Rolf O. Ehrhardt University of California School of Medicine, San Francisco, CA BioCision LLC, Larkspur, California Curr. Protoc. Immunology. 2012 Nov; 99 Appendix 3G Standardized Cryopreservation of Pluripotent Stem Cells Rick I. Cohen, Maria L. Thompson, Brian Schryver, Rolf O. Ehrhardt Rutgers University, Piscataway, New Jersey BioCision LLC, Larkspur, California Curr. Protoc. Stem Cell Biology. 2014 Feb; 28 Unit 1C.14 Standardized Cryopreservation of Human Primary...

Open the catalog to page 5
2015 Product Catalog - 6

CoolCell LX For 12 standard 1.0 mL or 2.0 mL cryogenic vials, 1.0 mL fill per vial. Radially symmetric for uniform vial freezing. Numbered wells for easy sample identification. Beveled lid for secure gripping and easy opening. Exposed vial tops when lid is open for quick, organized removal of frozen samples. CoolCell FTS30 For 30 standard 1.0 mL or 2.0 mL cryogenic vials, 1.0 mL fill per vial. Controlled micro-convection for uniform freezing of 30 vials. Removable vial tray for one-step transfer of samples into and out of freezing chamber. Description CoolCell LX, purple CoolCell LX, green...

Open the catalog to page 6
2015 Product Catalog - 7

Cell Cryopreservation Accessories CryoCeps™ Cryogenic Vial Crippers Cryogenic vial grippers feature a unique design to grasp internal- or external-thread cryogenic vials. Easily sort or move vials while maintaining sterility and protecting fingers from frozen vials, dry ice and liquid nitrogen. 5 per pack. BCS-213MC « CryoCeps Cryogenic Vial Grippers, multi-color Patented hinged lid offers convenience and archival integrity, ensuring markings and vials remain in sync. Lid stays attached to base minimizing risk of separation and lid contamination. Lid is easy to open when frozen. Available...

Open the catalog to page 7
2015 Product Catalog - 8

Automated Cell Thawing System ThawSTAR™ automated cell thawing system addresses the last gap in the cell cryopreservation workflow: cell thawing. Replacing common methods of cell thawing such as swirling frozen vials in communal water baths and warming vials between hands - methods that are not standardized and potentially jeopardize the integrity and safety of the sample - ThawSTAR system ensures consistent and reproducible thawing. Utilizing patent-pending STAR™ sensing technology, ThawSTAR employs multiple detection mechanisms to determine vial temperature, phase change initiation and...

Open the catalog to page 8
2015 Product Catalog - 9

ThawSTAR™ Reproducibility 37°C Water Bath 1.8 mL cryogenic vials filled with 1 mL of cryopreservation medium (10% DMSO/20% FBS/70% DMEM) were fitted with an interior wall thermocouple (< 0.5 mm from internal wall surface) and a central axis thermocouple, frozen at -80°C, and maintained at -75°C in a CoolRack® on dry ice. Three vials were thawed in a 37°C water bath (left panel) or in the ThawSTAR™ System (right panel). The temperature profiles recorded by both thermocouples were very similar for both the water bath and the ThawSTAR thaw. For the water bath thaw, the vials were removed from...

Open the catalog to page 9
2015 Product Catalog - 10

ThawSTAR™ Performance cont. Cell Count Mesenchymal Stem Cells (MSC). 3 vials from LN2 stores were thawed via a dry bead bath and ThawSTAR automated system. Cell recovery and viability were measured immediately post-thaw (Day 1) and after 3 days growth (Day 3). Bead bath thaw >5 min, ThawSTAR thaw 2.5 min. - Data courtesy of Dr. Min Liu at Children’s National Hospital, DC Ordering Information ThawSTAR™ Transport and Thawing System ThawSTAR Transport and Thawing System is a complete solution for standardized thawing of cells from frozen storage. Components include ThawSTAR Automated Cell...

Open the catalog to page 10
2015 Product Catalog - 11

BioT Carrier Temperature Stability Chamber BioT™ Carrier is a portable, programmable 2-8°C cooling solution for transporting and maintaining temperature-sensitive laboratory research samples with confidence. Easily adjust the cooling temperature set point to raise or lower the chamber temperature to best suit your application. Transport cold samples between facilities, from clinic to lab, or over longer distances utilizing the car power adaptor. Rechargable battery The LCD display is easy to operate. Digitally program cooling temperature set point (°C/°F) and time. Display indicates battery...

Open the catalog to page 11
2015 Product Catalog - 12

Ultra-Low Temperature Stability System BioT™ ULT Transporter is a breakthrough portable solution for freezing, or transporting valuable frozen biological samples and other temperaturesensitive specimens. The versatile ultra-low temperature system maintains a stable < -70 to -50°C temperature range throughout its entire 8-inch working depth over an 8 hour period with the lid off. With the lid on, the transporter maintains < -70° to -50°C in the chamber for over 24 hours, enabling longer sample transport with virtually no temperature variation or risk of elevated temperatures that could...

Open the catalog to page 12
2015 Product Catalog - 13

BioT™ ULT Transporter Performance Lid open: Over 8 hours < -50°C Temperature profile of BioT™ ULT Transporter loaded with dry ice and with lid open. The entire 8 inch working depth of the transporter remains below -50°C (green shading) for over 8 hours with one charge of dry ice and with the lid open. Temperature readings were taken every 2 inches above the chamber floor for 8 hours. Inches above base chamber floor: 0 inches (dark purple), 2 inches (purple), 4 inches (lavender), 6 inches (dark blue), 8 inches (light blue). Lid closed: Over 24 hours < -50°C Temperature profile of BioT ULT...

Open the catalog to page 13

All BioCision catalogs and technical brochures

  1. CoolSink

    1 Pages

  2. XT Starter

    2 Pages

  3. CoolCell LX

    2 Pages