CHW Ag Test

CHW Ag Test

Product catalog summary
Overview: The Bioguard Canine Heartworm (CHW) Antigen Test is a rapid, qualitative test for detecting Dirofilaria immitis in dogs. It uses a sandwich lateral flow immunochromatographic assay to identify the presence of heartworm antigens in blood samples.
Kit Components: The kit includes a CHW Ag test device, disposable dropper, EDTA blood collection tube, assay buffer bottle, and an instruction manual. Available in 5, 10, or 20 test kits per box.
Specimen Requirements: The test can be conducted using dog’s whole blood, serum, or plasma.
Test Procedure:
  • Remove the test components from the box and place the cassette horizontally.
  • Collect the sample (whole blood, serum, or plasma) using a disposable dropper.
  • Add 1 drop (20μL) of the sample and 4 drops (100μL) of assay buffer into the sample well.
  • Interpret results within 5-10 minutes. Results after 10 minutes are invalid.
Interpretation of Results:
  • Positive: Both C and T bands appear.
  • Negative: Only the C band appears.
  • Invalid: No C band appears, regardless of T band presence.
Storage Instructions: Store kits between 2-30°C. Do not freeze. Allow kits to reach room temperature before use if stored cold. Avoid direct sunlight.
Precautions:
  • Adhere strictly to instructions for best results.
  • Check expiration date before use.
  • Do not reuse components; dispose of them according to Good Laboratory Practice (GLP).
  • Do not mix components from different lot numbers.
Limitations: The test is for veterinary use and in vitro diagnosis only. It may not exclude false negatives or positives. Clinical information and other diagnostic methods should be considered for a definitive diagnosis.
Contact Information: Bioguard Corporation, New Taipei City, Taiwan. Tel: +886-2-5591-6688, Fax: +886-2-6625-8182.
See more

Catalog excerpts

CHW Ag Test-1

2) Whole blood or plasma sample W science for animal care Collect sample 1 drop of blood or plasma Take blood or plasma 4 drops of assay buffer, wait for 5-10 mins. Canine Heartworm Antigen Test INTERPRETATION OF RESULTS 1) Positive: The presence of both C and T band, no matter T band is clear or vague. 2) Negative: Only clear C band appears. 3) Invalid: No colored band appears in C zone, no matter whether T band appears. Bioguard Canine Heartworm (CHW) Ag Test is a sandwich lateral flow immunochromatographic assay, developed and manufactured by Bioguard Corporation, for rapid and qualitative detection of Dirofilaria immitis in dog’s blood. The test device has a testing window, coated by an invisible T (test) zone and C (control) zone. When sample is applied into the sample well on the device, the reagent will laterally flow on the surface of the test strip. If there is enough CHW Ag in the sample, a visible T band will appear. The C band should always appear after a sample is applied, indicating a valid result. By this means, the device can accurately indicate the presence of CHW Ag in the specimen. KIT COMPONENTS 5 TESTS /BOX 10 TESTS /BOX 10 5 10 5 10 5 1 1 1 1 COMPONENTS CHW Ag test device Disposable dropper EDTA blood collection tube Assay buffer bottle Instruction manual SPECIMEN Dog’s whole blood, serum or plasma. TEST PROCEDURE Remove the sealed pouch, assay buffer bottle and EDTA blood collection tube from the box. Take out the cassette from the foil pouch and place it horizontally on a clean surface. Take dog’s whole blood, serum or plasma(centrifugation from EDTA tube) as sample. Take sample by disposable dropper, drip 1 drop(20μL) of sample and immediately drip 4 drops(100μL) of assay buffer into the well. Interpret the result in 5-10 minutes. The result after 10 minutes is not allowed to be read. Take serum (avoid the red blood cells). Collect sample STORAGE The kits should be stored between 2-30°C. DO NOT FREEZE. If they are stored under cold circumstance, keep them at room temperature for 15~30 minutes before use. Do not store the test kit in direct sunlight. The test kits are stable through the expiration date (24 months) marked on the foil pouch. PRECAUTIONS For best results, please strictly adhere to these instructions. Please pay attention to the expiration date marked on the foil pouch before using. Do not use the expired kits. Do not remove the kit from the foil pouch until the test is ready to be carried out in case the kit is overly exposed to the air and affected by humidity, and all the manipulating process should be finished within 10 minutes after the foil pouch is opened. All the test devices in the box, including test kit, dropper, assay buffer and EDTA tube are all disposable. Do not reuse. Once the test is finished, please properly discard all specimens and kits in accordance with Good Laboratory Practice (GLP). Do not move the test strip after sample applying into the sample well in case of abnormal occurrence on the test strip. The components in this kit have been quality-control tested as standard batch unit. Do not mix components from different lot numbers. LIMITATION The test is for veterinary use and in vitro diagnosis only, and it is not able to exclude all the possibility of false negative and false positive results caused by various factors. Hence, besides the results from test kits, veterinarians should also consider other clinical information and laboratory diagnostic methods to make the definite diagnosis in practice. 4 drops of assay buffer, wait for 5-10 mins. science for animal care 6F. No.20-1. Wugong 5th Road,Wugu District, New Taipei City 248020,Taiwan TEL : +886-2-5591-6688 FAX : +886-2-

 Open the catalog to page 1

All Bioguard corporation catalogs and technical brochures

  1. VLabs 3DX

    1  Page

  2. VLabs 3RX

    1  Page

  3. VLabs 4X

    1  Page

  4. CDV Ag Test

    1  Page

  5. CPV Ag Test

    1  Page

  6. VLabs 4LX

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.