1. Catalogs
  2. Bioguard corporation
  3. Leptospira IgM/IgG Ab Test

Leptospira IgM/IgG Ab Test

Leptospira IgM/IgG Ab Test

Product catalog summary
Overview: The Bioguard Leptospira IgM/IgG Antibody Test is a rapid, qualitative immunochromatographic assay designed for detecting Leptospira spp. IgM and IgG antibodies in canine blood. It uses a lateral flow method with a test window featuring two test bands (T1-IgM and T2-IgG) and a control band (C band).
Test Procedure:
  • Remove the test cassette from the foil pouch and place it on a clean surface.
  • Collect the dog's whole blood, serum, or plasma using an EDTA tube.
  • Using a disposable dropper, add 1 drop (20μL) of the sample and 4 drops (100μL) of assay buffer into the sample well.
  • Interpret results within 5-10 minutes; results after 10 minutes are invalid.
Storage Instructions:
  • Store kits between 2-30°C and avoid freezing.
  • Allow kits stored in cold conditions to reach room temperature (15-30 minutes) before use.
  • Avoid direct sunlight and adhere to the expiration date on the foil pouch.
Precautions:
  • Follow instructions strictly for accurate results.
  • Do not use expired kits or reuse any components.
  • Dispose of all materials according to Good Laboratory Practice (GLP).
  • Do not mix components from different lot numbers.
Limitations: This test is for veterinary use and in vitro diagnosis only. It may not exclude false negatives or positives, so additional clinical information and diagnostic methods should be considered.
Components: Each kit contains test devices, disposable droppers, EDTA blood collection tubes, an assay buffer bottle, and an instruction manual. Available in 5 or 10 test boxes.
Interpretation of Results:
  • Positive: Presence of both C and IgM(1)/IgG(2) bands.
  • Negative: Only the C band appears.
  • Invalid: No colored band in the C zone.
See more

Catalog excerpts

Leptospira IgM/IgG Ab Test-1

2) Whole blood or plasma sample ffe r science for animal care Leptospira IgM/IgG Ab Test Collect sample Leptospira IgM/IgG Antibody Test Take blood or plasma 1 drop of blood or plasma 4 drops of assay buffer, wait for 5-10 mins. INTERPRETATION OF RESULTS 1) Posi�ve: The presence of both C and IgM(1)/ IgG(2) band, no ma�er IgM(1)/ IgG(2) band is clear or vague. 2) Nega�ve: Only clear C band appears. 3) Invalid: No colored band appears in C zone, no ma�er whether IgM(1)/ IgG(2) band appears. Bioguard Leptospira IgM/IgG Ab Test is a sandwich lateral flow immunochromatographic assay, developed and manufactured by Bioguard Corpora�on, for rapid and qualita�ve detec�on of Leptospira spp. IgM and IgG An�body in dog‘s blood. The test device has a tes�ng window, coated by two invisible test band (T1-IgM and T2-IgG) and control band (C band). When sample is applied into the sample well on the device, the reagent will laterally flow on the surface of the test strip. If there is enough Leptospira Ab in the sample, a visible T band will appear. The C band should always appear a�er a sample is applied, indica�ng a valid result. By this means, the device can accurately indicate the presence of Leptospira Ab in the specimen. KIT COMPONENTS 5 TESTS /BOX 10 TESTS /BOX COMPONENTS Leptospira IgM/IgG Ab test device Disposable dropper EDTA blood collec�on tube Assay buffer bo�le Instruc�on manual SPECIMEN Dog’s whole blood, serum or plasma. TEST PROCEDURE Remove the sealed pouch, assay buffer bo�le and EDTA blood collec�on tube from the box. Take out the casse�e from the foil pouch and place it horizontally on a clean surface. Take dog’s whole blood, serum or plasma (centrifuga�on from EDTA tube) as sample. Take sample by disposable dropper, drip 1 drop(20μL) of sample and immediately drip 4 drops(100μL) of assay buffer into the well. Interpret the result in 5-10 minutes. The result a�er 10 minutes is not allowed to be read. 1) Serum sample 20μL 10μL Collect sample. Take serum (avoid the red blood cells). STORAGE The kits should be stored between 2-30°C. DO NOT FREEZE. If they are stored under cold circumstance, keep them at room temperature for 15~30 minutes before use. Do not store the test kit in direct sunlight. The test kits are stable through the expira�on date (24 months) marked on the foil pouch. PRECAUTIONS For best results, please strictly adhere to these instruc�ons. Please pay a�en�on to the expira�on date marked on the foil pouch before using. Do not use the expired kits. Do not remove the kit from the foil pouch un�l the test is ready to be carried out in case that the kit is overly exposed to the air and affected by humidity, and all the manipula�ng process should be finished within 10 minutes a�er the foil pouch is opened. All the test devices in the box, including test kit, dropper, assay buffer and EDTA tube are all disposable. Do not reuse. Once the test is finished, please properly discard all specimens and kits in accordance with Good Laboratory Prac�ce (GLP). Do not move the test strip a�er samples applied into the sample wells in cause of abnormal occurrence on the test strips. The components in this kit have been quality-controlled as a standard batch unit. Do not mix components from different lot number units. LIMITATION The test is for veterinary use and in vitro diagnosis only, and it is not able to exclude all the possibility of false nega�ve and false posi�ve results caused by various factors. Hence, besides the results from test kits, veterinarians should also consider other clinical informa�on and laboratory diagnos�c methods to make the definite diagnosis in prac�ce. 4 drops of assay buffer, wait for 5-10 mins. science for animal care 6F. No.20-1. Wugong 5th Road,Wugu Distri

 Open the catalog to page 1

All Bioguard corporation catalogs and technical brochures

  1. CHW Ag Test

    1  Page

  2. VLabs 3DX

    1  Page

  3. VLabs 3RX

    1  Page

  4. VLabs 4X

    1  Page

  5. CDV Ag Test

    1  Page

  6. CPV Ag Test

    1  Page

  7. VLabs 4LX

    1  Page

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.