video corpo

ELVeS® Radial®
8Pages

{{requestButtons}}

Catalog excerpts

ELVeS® Radial® - 1

ELVeS® Radial® Minimally invasive laser therapy  of venous insufficiency Safely to the next level Vena saphena magna Vena saphena parva Tributary veins Perforator veins

Open the catalog to page 1
ELVeS® Radial® - 2

The ELVeS® Radial® procedure ‒ the unique solution for the treatment of venous insufficiency The evolution of laser therapy As one of the world’s leading pioneers in the field of medical laser therapy, biolitec® launched the first medical 1470 nm diode laser in 2006 and the patented Radial® fiber in 2008 and has continued to improve endoluminal laser therapy ever since. Attain the next level safely with us

Open the catalog to page 2
ELVeS® Radial® - 3

The evolution continues Present and future call for even more intelligent solutions. Our striving to develop an outstanding system with respect to safety and flexibility for the endoluminal treatment of varicose veins has led us to 2ring technology. This principle, combined with the safest Fusion® fiber optics, the latest diode laser generation and treatment software, which can also incorporate a pulling device, offers: a high degree of standardization of your treatment always the right equipment for each of your approaches therapy also for complex vascular courses We are reaching the next...

Open the catalog to page 3
ELVeS® Radial® - 4

ELVeS® Radial® 2ring The dual-phase radiation with the ELVeS® Radial® 2ring fiber is the best choice for a perfect result, not only for experienced physicians but also for new users who demand efficient, safe, and easy-to-use technology. With this laser fiber the energy is split into two rings. This allows safe closure of the vein with a low energy density in each ring a perfectly centered fiber tip due to the pre-shrinkage effect optimal, homogeneous radiation on the vessel wall (even with a large diameter >15 mm) a simple retraction technique (possible with the push of a button) ELVeS®...

Open the catalog to page 4
ELVeS® Radial® - 5

Safe through Fusion® Why Fusion®? Because quality matters Due to of its high quality standards, biolitec® has understood from the beginning what is important when it comes to safety. For this reason, all of biolitec®’s distal quartz glass caps and laser fibers are fused to one another with the help of Fusion® technology. Simple gluing does meet the current standard for these products (DIN EN ISO 10555-1, Annex B), but not the high demands of modern minimally invasive laser medicine. biolitec® has developed the Fusion® process and thus set the standards worldwide. On the right side is a...

Open the catalog to page 5
ELVeS® Radial® - 6

T he evolu tio contin n ues ELVeS® Radial® 2ring P ro Simple and Safe ‒  The All-Round Solution with the Integrated Safety Concept The ELVeS® Radial® 2ring process is the optimal solution for effective and careful endovenous laser therapy and sets new standards for patients and users. Performing endovenous laser therapy has never been easier. Thanks to the homogeneous laser radiation made possible by an exclusive and patented distal design, the ELVeS® Radial® 2ring procedure minimizes the risk of vein perforation and ensures high echogenic visibility. The 1470 nm laser energy is preferably...

Open the catalog to page 6
ELVeS® Radial® - 7

INVISIBLE LASER RADIATION AVOID EYE OR SKIN EXPOSURE TO DIRECT OR INDIRECT RADIATION CLASS 4 LASER PRODUCT Diode-Laser 1470 +/- 30 nm CW 15 W(Max.) EN 60 825-1:200 8 EN6 0601-2-22:2007 Model LEONARDO® Mini 1470 LEONARDO® 1470 LEONARDO® 1940 VISIBLE LASER RADIATION AVOID EYE EXPOSURE TO DIRECT RADIATION CLASS 3RLASER PRODUCT Diode-Laser 635 +/- 10 nm CW 4 mW (Max.)(Aiming) Diode-Laser 532 +/- 10 nm CW 1 mW(Max.)(Aiming) EN 60825-1:2008 EN60601-2-22:2007 CeramOptec GmbH Slemensstr. 44, D-53121 Bonn green 1 mW, red 4 mW, user controlled intensity user controlled intensity Treatment mode CW,...

Open the catalog to page 7
ELVeS® Radial® - 8

to learn more about a whole new world of minimally invasive laser therapies The path is the goal ‒ The biolitec®evolution continues biolitec ® worldwide biolitec AG Vienna, Austria phone: +43 1 3619 909 50 info@biolitec.de www.biolitec.com biolitec biomedical technology GmbH Jena, Germany Phone: +49 3641 519 53 0 biolitec Schweiz GmbH Wollerau, Switzerland Phone: +41 55 555 30 20 biolitec España Madrid, Spain Phone: +34 91 9910857 biolitec Italia SRL Milano, Italy Phone: +39 02 8423 0633 biolitec Tıbbi Cihazları Ltd. Şti. Istanbul, Turkey Phone: +90 216 574 7456 PT. Biolitec Tangerang,...

Open the catalog to page 8

All Biolitec catalogs and technical brochures

  1. TULA® DUAL

    4 Pages

  2. LaEvita

    2 Pages