video corpo

ENT
8Pages

{{requestButtons}}

Catalog excerpts

ENT - 1

 Minimally invasive  laser therapies in ENT Excellent hemostasis

Open the catalog to page 1
ENT - 2

Laser solutions for outpatient ENT surgery The biolitec® laser and fiber systems have a compact, maintenance-free design for effective and safe use in ENT surgery. Specifically developed for various applications, this sophisticated system offers a wide range of possibilities for minimally invasive laser therapy of ear, nose and throat ailments. Whether in the OR, in out-patient clinic or in private practice – the range of applications can be extended according to individual requirements. Effective, precise, minimally invasive with dedicated solutions in the following areas: Endonasal...

Open the catalog to page 2
ENT - 3

Significantly better hemostasis and control The wavelength of 980 nm has a high absorbance in hemoglobin whereas the 1470 nm has a high absorbance in water. The thermal penetration depth of the LEONARDO® DUAL laser therefore can be adjusted to the needs of the particular ENT application by just a finger tip. This allows safe and precise procedures to be performed close to delicate structures while protecting the surrounding tissue. Compared to the CO2 laser, this special wavelength set exhibits a significantly better hemostasis and prevents bleeding during the operation, even in hemorrhagic...

Open the catalog to page 3
ENT - 4

Ambulatory treatment Endo Nasal surgery Endoscopic surgery is an established, modern process in the treatment of nasal and paranasal sinuses. However, due to the strong bleeding tendency of the mucosal tissue, surgical treatment in this area is often challenging. A poor operating field of vision due to bleeding often results in imprecise work; prolonged nasal packing and significant patient and doctor effort is usually unavoidable. The main imperative in endonasal surgery is to maintain the surrounding mucosal tissue as much as possible. New designed fiber with special conical fiber tip on...

Open the catalog to page 4
ENT - 5

Oropharynx One of the most frequent operations in the oropharynx area is laser tonsillotomy in children (Kissing Tonsils). In pediatric symptomatic tonsillar hyperplasias, LTT represents a sensible, gentle and very low risk alternative to tonsillectomy (children up to 8 years of age). The risk of post-operative bleeding is minimal. The minimal amount of post-operative pain thanks to the shortened period of healing, the ability to perform out-patient operations (with general anesthesia) and the leaving behind of a tonsillar parenchyma are significant advantages of laser tonsillotomy....

Open the catalog to page 5
ENT - 6

Clinical applications Otology In the field of Otology, biolitec®’s advanced LEONARDO® diode laser systems extend the range of minimally invasive treatment options. Laser PARACENTESIS is a minimally invasive and bloodless treatment operation that opens the eardrum with a single shot contact technique. The small circular perforated hole in the eardrum, performed by the laser, has the advantage of remaining open for about three weeks. The emission of liquid is easy to handle and therefore the healing process after inflammation is considerably shorter, compared to conventional surgical...

Open the catalog to page 6
ENT - 7

INVISIBLE LASER RADIATION AVOID EYE OR SKIN EXPOSURE TO DIRECT OR INDIRECT RADIATION CLASS 4 LASER PRODUCT Diode-Laser 980 +/- 30 nm CW 30 W(Max.) VISIBLE LASER RADIATION AVOID EYE EXPOSURE TO DIRECT RADIATION CLASS 3RLASER PRODUCT Diode-Laser 635 +/• 10 nm CW 4 mW (Max.)(Aiming) Diode-Laser 532 +/- 10 nm CW 1 mW(Max.)(Aiming) EN 60825-1:2008 EN60601-2-22:2007 CeramOptec GmbH Siemensstr. 44, D-53121 Bonn LEONARDO® Model REF Wavelength Power LEONARDO® Mini Dual SL980+1470nm16W 980 nm and 1470 nm 11 W (980 nm) / 5 W (1470 nm) Fiber diameter Aiming beam Treatment mode CW, Pulse Mode (optional)...

Open the catalog to page 7
ENT - 8

to learn more about a whole new world of minimally invasive laser therapies biolitec ® worldwide biolitec AG Vienna, Austria phone: +43 1 3619 909 50 info@biolitec.de www.biolitec.com biolitec biomedical technology GmbH Jena, Germany Phone: +49 3641 519 53 0 biolitec Schweiz GmbH Wollerau, Switzerland Phone: +41 55 555 30 20 biolitec España Madrid, Spain Phone: +34 91 9910857 biolitec Italia SRL Milano, Italy Phone: +39 02 8423 0633 biolitec Tıbbi Cihazları Ltd. Şti. Istanbul, Turkey Phone: +90 216 574 7456 PT. Biolitec Tangerang, Indonesia Phone: +62 21 537 2994 OOO biolitec Spb...

Open the catalog to page 8

All Biolitec catalogs and technical brochures

  1. TULA® DUAL

    4 Pages

  2. LaEvita

    2 Pages

  3. ThyLA DUAL

    6 Pages

  4. CALA

    6 Pages

  5. LEONARDO®

    6 Pages

Archived catalogs

  1. PLDD

    2 Pages

  2. Pneumology

    6 Pages

  3. LHP

    12 Pages

  4. FiLaC

    12 Pages

  5. HeLP™

    12 Pages

  6. EVOLVE™

    12 Pages

  7. EVOLVE™ DUAL

    12 Pages

  8. Evolve™ 180

    12 Pages