MIX 4 - MIX 5

MIX 4 - MIX 5

MIX 4 - MIX 5

Product catalog summary
Description and Details:
The MIX 4 and MIX 5 safety gas mixers are designed to supply medical gas mixtures (O²/N²O or O²/Air) with high precision. These devices are primarily used in workrooms, operating theatres, and examination rooms. Key features include the ability to deliver very low flow rates, high precision through twin reading tubes, separate gas flow readings, and individual calibration of flowmeters. They are insensitive to supply pressure variations and include safety regulations to prevent oxygen concentrations below 20%. In case of oxygen supply failure, nitrous oxide is completely cut off, and an audible alarm is triggered. An auxiliary oxygen supply outlet and an integrated oxygen bypass push button are also included.

Specifications:
MIX 4 - O²-N²O Mixer:
- O2 Flow: 0.2 to 10 L/min
- N²O Flow: 0.2 to 10 L/min
- Mixture Flow: 0.4 to 20 L/min (Oxygen 50%)
- O2+ Flow: 55 L/min (Optional)
- Supply Pressure: 2.5 to 7 bars
- Alarm Trigger Pressure: 1.5 bar
- Dimensions: 320x150x135 mm
- Weight: 2.8 kg

MIX 5 - O²-N²O-AIR Mixer:
- Selector prevents simultaneous AIR and N²O flow
- AIR Flow: 0.2 to 15 L/min
- Weight: 3.5 kg

Both devices comply with the EN-740 standard and the European Medical Device Directive 93/42/CEE.

Options:
- Outlet cone for quick O² connection
- Gas supply hoses
- Universal rail adapter
- Tube fixation adapter
- Oxygen sensor with adapter
- Patient circuit (connector, pipe, mask, balloon, and valve)
See more

Catalog excerpts

MIX 4 - MIX 5-1

EQUIPEMENTS HOSPITALIERS

 Open the catalog to page 1
MIX 4 - MIX 5-2

DESCRIPTION / DETAILS Les Mélangeurs MIX4 et MIX5 sont des dispositifs permettant la fourniture d’un mélange de gaz médicaux (O²/N2O ou O²/Air). Comparés aux MIX 2 et MIX 3 ces mélangeurs permettent une lecture plus précise par leur fonctionnement en tubes jumelés (O², N²0). Utilisés majoritairement en salle de travail, bloc opératoire et salle d’examen les avantages et sécurité de ces dispositifs sont les suivants : n Délivrer de très faibles débits n aut niveau de précision grâce à des tubes de lecture jumelés (O², N²O) H n Lecture séparée du débit de chaque gaz. n Réglage précis : étalonnage...

 Open the catalog to page 2

Archived catalogs

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.