BiomediQA : Global overview
15Pages

{{requestButtons}}

Catalog excerpts

BiomediQA : Global overview - 1

Innovation for medical physics and radiation protection NUCLEAR MEDICINE DENTAL RADIOLOGY Quality Radiation protection medical physics

Open the catalog to page 1
BiomediQA : Global overview - 2

Summary Created since 2004 according to an original model, conducive to new ideas and creativity, BIOMEDIQA enters a new era of its development. This is a new chapter in our history that is being written, about digital transition and unprecedented technological change. WHAT BRING US TOGETHER IS: PASSION Impassioned about our job, we make possible the most complex or daring projects. We are all, driven by the same values which are: ■ The quest for quality, which is based on a very strong competence and uncompromising rigor ■ The spirit of service: the trust of our customers is based on our...

Open the catalog to page 2
BiomediQA : Global overview - 3

Group BIOMEDIQA Timeline O BIOMEDIQA Creation of BIOMEDIQA Group Internal Quality Control in nuclear medicine Winner of the «Nord Entreprendre price» External RPO Master Degree in Creation issued by the Senate Providing courses in radiation protection of workers J Engineering in nuclear medicine Internal quality control in computed tomography -200^ ASN1 partner 1st international’s Congress of risks management in radiotherapy Research Partnership with «Ecole centrale de Lille» Calculation of the organ’s dose Industrial partnership PHILIPS Partnership scientist with «General de Sante - Groupe...

Open the catalog to page 3
BiomediQA : Global overview - 4

Dose Archiving and Communication System For all radiological imaging techniques BACKGROUND The 2013/59/EURATOM directive, has been applied in Europe during the year 2018, impacting the code of public health in terms of radiation protection. The fulfil legal requirements, BIOMEDIQA proposes to healthcare professionals: ■ A process of traceability and optimization of the radiation dose delivered to patients. ■ A risk management tool. Reports, archives & manages patient dose OPTIMIZE the dose & image’s quality CONTROL risks OUR SOLUTION DoSITRACE is a DACS (Dose Archiving and Communication...

Open the catalog to page 4
BiomediQA : Global overview - 5

Dosimetry by RadioChromic Film skin-mapping of the real patient dose Dosinvivo is an innovative technology for radiochro- great variability of the irradiation doses delivered to patients in interventional radiology, interventional procedures can lead to the appea rance of deterministic effects. mic film dosimetry. This technique ensures better risk prediction and patient monitoring. It was designed and developed by BIOMEDIQA. ■Placed on the patient’s skin, at the entrance of the Example of deterministic effects: x-ray beam, during the interventional examination, these films make it possible...

Open the catalog to page 5
BiomediQA : Global overview - 6

RMP RISK MANAGEMENT PLATFORM Cloud Platform for Risk Management successfull certification and labeling According to ASN1 Guides and HAS2 Certification for Heath institutions PREVENTIVE METHOD RMP platform is a tool for internal risk management (preventive and corrective) and decision support. FMECA: Failure Modes, Effects and Criticality Analysis. This platform has been designed to meet not only the Goals: Write all risks for an activity that can be sources of SE. ■ Thematic creation (process, item). ■ Criticality assessment. ■ Preventive action plan with expected criticality. ■ Result of...

Open the catalog to page 6
BiomediQA : Global overview - 7

Smart alert system for power on & X-ray emission According to ‘NFC 15-160’ standard and REGULATORY STANDARDS According to NFC-15-160 standard, access to an operating room equipped with an X-ray device must include appropriate risk signalling. DOSALERT is an X-ray emission signaling device for the operating room. This signaling allows staff outside the operating room to know if the image intensifier is powered on and whether or not it emits X-rays inside the room. Thanks to this signalling, staff members outside the operating room know if the image intensifier in the room is: This device...

Open the catalog to page 7
BiomediQA : Global overview - 8

TRAINING COURSES o BIOMEDIQA Certified professional Registration Radiation protection of Patients training coursesn°31590612159 Radiation protection of staff Quality Controls: dental equipment, computed tomography In order to ensure your compliance with regulatory requirements, BIOMEDIQA offers training courses in radiation protection and quality control. OUR STRENGTHS ■ Certified training organization (approval number: 31 59 06121 59) ■ Long training experience: More than 1500 trained people. ■ Our expertise in the medical imaging field, guarantee of quality. ■ Possibility of split...

Open the catalog to page 8
BiomediQA : Global overview - 9

according to the decree n°2016-1074, August 3rd 2016 (French legislation) GROUND DELIMITATION STRIP SIGNALING CLOVER Dimension (L x h): 13 x 18 cm Material: Adhesive vinyl 120µ 4 colors : blue, green, yellow, orange 2 models : ■ Irradiation risk (radiology) ■ Irradiation and Contamination risk (nuclear medicine). Decree No. 2016-1074 of 3 August 2016 sets new rules Tape Text: Regulated Crossing Dimension (h x w): 5 x 250 cm Color: blue, green, yellow or orange Material: special adhesion vinyl polymer (adhesive special for floor), with anti-slip granular lamination. for the protection of...

Open the catalog to page 9
BiomediQA : Global overview - 10

Medical Physicist Radiation Rotediran Officer (RpO)Accompaniment & assistancein medical physics and radiation protection MEDICAL PHYSICS RADIATION PROTECTION OF STAFF DESIGN OFFICE The optimization of the radiological dose delivered to the patient and the management of the associated risk, is an important issue of medical imaging and radiotherapy. BIOMEDIQA brings you its expertise and know-how in medical physics and radioprotection of patients. OUR SERVICES ■ Writing & Updating the Medical Physics Organization Plan ■ Assessment and optimization of the patient dose ■ Assistance in...

Open the catalog to page 10
BiomediQA : Global overview - 11

Internal Quality Control interventional radiology according to the decision of From March 31, 2017, comes into force the decision of SERENITY PACK 11/21/2016 of the ANSM1 governing the quality control of radiodiagnostic equipment used for radio-guided interventional procedures. On this same date the decision of Below is a comparison of the 2007 decision with that of 2016: NEW ANSM1 DECISION Includes all conventional and interventional devices Concerns the quality control of interventional devices Performing of 3 quarterly and 1 annual IQC over one year. Therefore we work 3 times a year....

Open the catalog to page 11