1. Catalogs
  2. Bioner
  3. Top DM catalogue
video corpo

Top DM catalogue
1 /36Pages

Top DM catalogue

Top DM catalogue
1 /36Pages

Catalog excerpts

Top DM catalogue-1

$BIONER DENTAL IMPLANTS

 Open the catalog to page 1
Top DM catalogue-3

BIONER, since 1992 leading the way Since its founding in 1992, Bioner’s activities have been geared toward supplying the Spanish implant market. In recent years Bioner has begun its international expansion without compromising the values that have driven its growth: the precision and quality of its products, the ongoing collaboration with professionals and prestigious organisations, and a order technical and commercial service.

 Open the catalog to page 3
Top DM catalogue-6

IMPLANT DESIGN Implant system TOP DM a versatile, advanced solution Bioner has placed all the technical and scientific know-how gained over 25 years of history at the service of the TOP DM system, an implant that optimises the management and care of patient tissues to obtain excellent short and long-term results. TOP DM is designed with an expanding cone-shaped core of increasing diameter from the apical to the coronal area, thus favouring insertion in areas with low bone volume. Its dual pitch thread and neutral apex endure quick, safe insertion and optimal primary stability, ideal for post-extraction...

 Open the catalog to page 6
Top DM catalogue-7

IMPLANT DESIGN Indexed hexagonal conical connection. 24° cone. Stable implantprosthesis connection. Grade 5 titanium. Maximum stability and reliability in the prosthetic connection. Unique 3 mm connection for all implant diameters. Simplifies management of prosthetic attachments. Straight neck + Spiral up to the platform. Subcrestal insertion. Simplifies passage through the cortical, reducing post-surgical tension and preventing marginal bone loss. Dual pitch thread for fast, easy insertion. Pitches of 1.8 (DM-35), 2.5 (DM-40) and 2.4 (DM-50). Bioetch Surface® Fast osseointegration. Conical cylinder...

 Open the catalog to page 7
Top DM catalogue-8

BIOETCH® SURFACE Bioetch®, the best surface in grade 5 Titanium Change the technological standard: macro and micro texturised surfaces obtained by etching with acid instead of sand-blasting. The TOP DM implant is Bioner’s response to the requirements of modern implantology: ensure stable internal connections with reduced diameter implants. For this reason, the manufacturer uses grade 5 titanium. Fig. 1 Internal connections and reduced diameters weaken implant walls. The Classical treatment of grade 5 titanium implants includes sand-blasting. This procedure gives the implants an adequate surface...

 Open the catalog to page 8
Top DM catalogue-9

BIOETCH® SURFACE Characteristics of the Bioetch® surface The Bioetch® surface is characterised by a very regular pattern of macro and microcavities with an average roughness of 1.3 µm that favours micro-fixation of the bone during the osseointegration process. Regular pattern of macro and microcavities Optimisation of the micro fixation in neoformed bone Improvement of the bone-implant contact (BIC) (1) Mag 2700X. (2) Mag 500X. (3, 4) “Influence of a new implant design to prevent crestal bone reabsorption and increase implant contact. A histomorphometric study in American Foxhound dogs.” Calvo-Guirado...

 Open the catalog to page 9
Top DM catalogue-10

IMPLANT PRESENTATION TOP DM is available in 3 different diameters of 3.5, 4 and 5 mm to cover all regenerative needs, from the reconstruction of small parts to the rehabilitation of posterior areas and even for use in aesthetics. TOP DM is available in lengths of 7 mm up to 15 mm in all diameters. For severe cases of atrophy, Bioner offers the SHORT DM line of implants available in

 Open the catalog to page 10
Top DM catalogue-11

IMPLANT PRESENTATION The packaging for TOP DM implants is specially designed, on the one hand, to make handling easier during surgery and, on the other, to simplify storage and fast identification of the different sizes. The outer label consists of three stickers showing the basic implant identification information (reference and batch No.). One of these stickers may be affixed to the implant passport Bioner provides its customers. Opening the package using the easy-open system exposes a double blister pack and implant tube that guarantees sterility and safety during pre-surgical handling. The...

 Open the catalog to page 11
Top DM catalogue-12

SURGICAL INSTRUMENTS The TOP DM surgical kit is simple and intuitive and includes all the tools required for implant placement. It has been designed to simplify the surgical procedure as much as possible so that the implantologist can concentrate on the patient. Simplified drilling improves the primary stability of the implant, favouring early loading. The diameter drills and the stop system favour optimal and safe drilling. Lance drill and extender F-EXT Drill extender - Cylindrical drills Pilot drills Hard bone drills Drill shafts available in two lengths.

 Open the catalog to page 12
Top DM catalogue-13

SURGICAL INSTRUMENTSTransporters DM-CiC Transporter C Short Angle’ DM-CiL Transporter C Wide angle DM-CiC Short Ratchet Transporter' DM-CiC Long Ratchet Transporter Screwdrivers and other elements _(L) PUC Manual Screwdriver/Short Unigrip Ratchet1 8 mm PUM Manual Screwdriver/Medium Unigrip Ratchet1 14 mm PUL Manual Screwdriver/Long Unigrip Ratchet1 22 mm DCAUC Short Unigrip CA Screwdriver1 8 mm DCAUM Medium Unigrip CA Screwdriver 13 mm DCAUL Long Unigrip CA Screwdriver1 21 mm PCTT Medium Manual Tubular Screwdriver 12 mm DCATT Tubular Ratchet CA Screwdriver1 14 mm I35 Implant paralleling tool/Gum...

 Open the catalog to page 13
Top DM catalogue-14

Drilling protocol The drilling protocol of the TOP DM implant is characterised by its simplicity. The surgical box is reduced in size to simplify handling in the surgical field. The bands of colour on the tray surgical and the bone type markers indicate the sequence of drills to be used in any surgical situation. Drilling sequence Pilot Drills Bone Drills III-IV Pilot Drills Bone Drills Implant paralleling tool pin. Probe for selecting the abutment Abutment selection guide Drill marks Implant transporter Knurled screwdriver Tubular screwdriver (Minicone)

 Open the catalog to page 14
Top DM catalogue-15

Example of drilling for an 11.5 mm implant for the different diameters available. The drill depth is 13 mm for 1.5 mm infraosseous insertion. The pilot drill is not a burr it should go the full depth; its neutral tip does not modify the drilling depth (optional). H Hard bone drill (optional).

 Open the catalog to page 15
Top DM catalogue-16

Placement of the implant The TOP DM implant is inserted directly using the transporter tool included in the surgical kit. There are no intermediate elements to be removed after implant insertion thus making the procedure rapid and avoiding unnecessary handling. The kit surgical includes transport keys for contra-angle implant placement with a ratchet key. Tissue management. Selecting the abutment. The surgical versatility of the TOP DM implant enables juxta-osseous or infraosseous insertion to prevent marginal bone loss and favour optimal aesthetic emergence. The TOP DM implant is designed for...