info@biopac.com support@biopac.com www.biopac.com PRODUCT SHEET MP36R SYSTEMS MP36R Licensed Systems – See corresponding license page for more information: System Windows Part # MP36R with Basic Scripting MP36R plus Network Data Transfer The MP36R data acquisition unit has an internal microprocessor to control data acquisition and communication with the computer. The MP36R unit takes incoming signals and converts them into digital signals that can be processed with the computer. There are four analog input channels, one of which can be used as a trigger input. To record signals, connect the MP36R unit to the computer and connect electrodes, transducers, and I/O devices to the MP36R unit. MP36R Symbology Symbol Description Explanation Type BF Equipment Consult accompanying documents Turns MP36/35 on assuming AC300A power adapter is powered by the mains Turns MP36/35 off if but AC300A power adapter remains powered by the mains Direct current Direct current output COMPLIANCE SAFETY The MP36R satisfies the Medical Safety Test Standards affiliated with IEC 60601-1 and is designated as Class I Type BF medical equipment EMC The MP36R satisfies the Medical Electromagnetic Compatibility (EMC) Test Standards affiliated with IEC 606011-2. Types of Input Devices There are three types of devices that connect to the MP36R: electrodes, transducers, and I/O devices. • Electrodes are relatively simple instruments that attach to the surface of the skin and pick up electrical signals in the body. Transducers, on the other hand, convert a physical signal into a proportional electrical signal. Input/Output devices (I/O for short) are specialized devices like pushbutton switches and headphones. BIOPAC Hardware | MP36R Systems | Page 1 - 5
Open the catalog to page 1PRODUCT SHEET info@biopac.com support@biopac.com www.biopac.com Simple Sensor Connectors Regardless of the type of device connected, every sensor or I/O device connects to the MP36R using a “Simple Sensor” connector. Simple Sensor connectors are designed to plug only one way into the MP36R—it’s not possible to plug items in upside down or into the wrong socket. • Electrodes, transducers, and the pushbutton switch all connect to the channel input ports on the front panel of the MP36R. Headphones and the stimulator connect to the “Analog out” port on the back panel of the MP36R. (There is...
Open the catalog to page 2PRODUCT SHEET info@biopac.com support@biopac.com www.biopac.com USB Connection The MP36R connects to the computer via a USB Port, located just below the word USB. • Uses a standard USB connector. • Should only be used to connect the MP36R to a PC or Macintosh. Headphone Output • Accepts a standard (1/8” or 3.5 mm) stereo headphone jack. I/O Port • Accepts a DB 25 Female connector. • Input/Output port used to connect digital devices to the MP36R. Trigger Input • Accepts a male BNC connector. • Input port used to send trigger signals from another device to the MP36R. • See External Trigger...
Open the catalog to page 3PRODUCT SHEET info@biopac.com support@biopac.com www.biopac.com MP36R Specifications Electrode Check Resistance Range: Analog inputs: 4 isolated channels (front panel CH 1–CH 4) Sample rate: Trigger Input: Adjustable threshold level with Positive or Negative Trigger 24-bit (before digital filtering) Signal to noise ratio: > 89 dB min Tested at lowest Gain at 1,000 s/s with grounded front end Voltage resolution: Gain dependent: 2.38 microvolts /bit (Gain 5) to 0.024 nanovolts /bit (Gain 50,000) Storage buffer: Input voltage range: Gain dependent: 400 microvolts to 4.0 Volts p-p Input noise...
Open the catalog to page 4info@biopac.com support@biopac.com www.biopac.com PRODUCT SHEET Mains Power Disconnection To completely disconnect the MP36R unit and the AC300A power adapter from all poles of the supply mains, extract the power cord plug from the mains outlet. Please note that the power switch on the back of the MP36R unit turns power ON and OFF to the MP36R unit only. Extract the plug by grasping the plastic shell of the plug and pull firmly away from the mains outlet in a direction perpendicular to the face of the mains outlet. Take care not to touch the metal blades associated with the plug. This...