Catalog excerpts
WORKS IN LARGE VOLUME: • Incubators • Gloveboxes • Refrigerators • Animal cages • Plant chambers • Plastic bags • Ice boxes • Tents • Etc. NEW TOOL The new ProOx P360 is a handy little tool for people who do oxygen sensitive work. It makes oxygen control easy. PHYSIOLOGIC CONTROL Control setpoint can be anywhere from 0.1-99.9% oxygen. The ProOx P360 senses oxygen inside the chamber and infuses either nitrogen to lower the concentration or oxygen to raise it. WORKS IN ANY CHAMBER The ProOx P360 fits and controls oxygen within any semi-sealed enclosure. Its high output makes it ideal for larger chambers, and most chambers can be fitted in minutes. CONTROL IS EFFICIENT Feedback from sensor tells the ProOx P360 exactly when and exactly how much gas to infuse. No gas is ever wasted! OPERATION IS SIMPLE Oxygen is quickly taken to setpoint and held there indefinitely. Any disturbances are immediately detected and corrected. Check calibration once in a while and don’t run out of gas. Otherwise it’s all automatic! HANDLES ANY JOB ...Where ambient air oxygen (21%) is too high or too low, the ProOx P360 can provide any other level you need. ...Where ambient atmosphere is not air, the ProOx P360 can restore and maintain air-equivalent oxygen. ...Where oxygen consumptive or generative processes need to be countered, the ProOx P360 can hold oxygen stable against destabilizing loads. It can work continuously year round or on occasion as needed. No other oxygen tool offers so much value!
Open the catalog to page 1Installation Schematics Control via Adapter Plate (shown on BioSpherix C-Shuttle) Direct insertion of sensor/tubing (shown on incubator) ProOx P360 can control any large semi-sealable chamber by one of the methods shown above, installation may vary based on chamber. Installation 1. Set ProOx P360 on or near host chamber and plug it in. 2. Hook up sensor and gas infusion tube and insert both into the chamber. 3. Hook up gas supply. From outside the host chamber, the ProOx P360 works by remotely sensing the oxygen concentration inside the chamber and infusing either nitrogen to lower it or...
Open the catalog to page 2Hypoxia Control Scenario 1 NORMOBARIC OXYGEN FEEDBACK CONTROL ProOx P360 works in semi-sealable chambers. It controls chamber oxygen by forced displacement of gas inside chamber via dilution with either oxygen-rich or oxygenpoor control gas. Pressure inside the chamber stays the same as pressure outside. Dilution is a logarithmic process. The further away from ambient, the slower it goes. But closed-loop control is efficient. By constantly monitoring chamber oxygen, it promptly gets to setpoint. It responds immediately to correct any disturbance. It automatically adjusts to different loads....
Open the catalog to page 3Front Panel ELECTRICAL POWER: 12 VDC at 2.5A 1. Needle Valve: Sets infusion rate of control gases in each chamber to accommodate different dynamics. Can manually override controller to shut off gas. 2. Bleed Valve: Bleeds gas (nitrogen or oxygen) out of gas supply line. Used for calibrating sensor and de-pressurizing gas supply. 3. Controller: Bright green 0.4 inch digits. Continuously displays oxygen concentration at sensor, unless pre-empted by other operations. Displays menu items and settings during programming. 4. Gas Switch: Manually overrides controller to shut off gas. 5. Alarm...
Open the catalog to page 4All BioSpherix Ltd. catalogs and technical brochures
-
Animal Equipment Catalog
18 Pages
-
CELL RESEARCH PRODUCTS
26 Pages
-
Xvivo System
1 Pages
-
OxyStreamer
2 Pages
-
ProCO2 P120
4 Pages
-
ProOx P110
4 Pages
-
ProOx C21
4 Pages
-
OxyCycler C42
4 Pages
-
I-Hood
2 Pages
-
OxyCycler GT41
4 Pages
-
Oxycycler GT4181N
4 Pages
-
Oxycycler GT4181C
4 Pages
-
C-Chamber
2 Pages
-
C-SHUTTLE
4 Pages
-
I-GLOVE
4 Pages