Neuromonitor Catalogue
9Pages

{{requestButtons}}

Catalog excerpts

Neuromonitor Catalogue - 1

BIOSCOPE Safe Protection of Neural Functions

Open the catalog to page 1
Neuromonitor Catalogue - 2

Bioscope Safe Protection of Neural Functions INNOVATIVE MEDICAL TECHNOLOGIES Leading company in ventilation and respiratory equipment Since 2012, Biosys has been producing innovative medical technologies with experienced engineers and doctors, R&D knowledge, and creates new generation solutions by detecting the sector's needs. With continuous improvement in health services all around the world, Biosys allow more people to access these services. Biosys and Arçelik, which previously had made a global impact with Biyovent, the Intensive Care Type Mechanical Ventilation Device, and a vital...

Open the catalog to page 2
Neuromonitor Catalogue - 3

Bioscope Safe Protection of Neural Functions DETAILED RESEARCH CORRECT RESULT We Make a Difference In Intensive Care Systems With New Generation Technology. As Biosys, we realized that, as a result of our research to meet the needs of the health sector, there are deficiencies, especially in intensive care systems and that these deficiencies directly affect both healthcare professionals and patients. In the direction of this awareness, we have developed the Biyovent Intensive Care Type Mechanical Ventilator Device as a result of the 5-year R&D work that we have progressed with the opinions of...

Open the catalog to page 3
Neuromonitor Catalogue - 4

Bioscope Safe Protection of Neural Functions INNOVATIVE DESIGN, FUNCTIONAL USAGE It Was Designed For Health Care Professionals And Optimized For Patients The Bioscope Neuromonitor Device minimizes the risk in operations such as thyroid, parathyroid, hand-face surgery, ENT surgery where the nerve injury risk is high. It provides patient safety by testing nerve-function integrity during the operation. The device has no diagnostic or therapeutic features. The feedbacks are made according to the data obtained from the doctors. Suitable for Pediatric, Adult, and Neonatal (Optional) Patients...

Open the catalog to page 4
Neuromonitor Catalogue - 5

Bioscope Safe Protection of Neural Functions EASILY CARRYABLE, MULTIFUNCTIONAL NEUROMONITOR Working Principle Electrodes are used for direct contact with the laryngeal nerve and surrounding tissues. Electrical stimulation is generated with the electrode used. The emerging electrical stimulation is transmitted to the throat by the recurrent laryngeal nerve. The recording electrode converts the electrical signal into sound and image. The signals that are converted into images are controlled by the surgeon. If a waveform is seen in the monitor, it is understood that recurrent laryngeal nerves...

Open the catalog to page 5
Neuromonitor Catalogue - 6

Bioscope Safe Protection of Neural Functions HIGH DATA SECURITY, AND DETAILED DOCUMENTATION Your health is in safe hands with high safety measures BiO2Flow farklı terapi ihtiyaçlarına sahip hastalara uyum sağlayacak biçimde tasarlanmıştır. Bu benzersiz Consumption Informationayar özellikleriyle esnekliğini farklı modlarıyla ve hassas destekler. Hastanın, sekresyonu kolay atması için The device is powered by an adapter cable and a avantaj sağlar. control connection cable. Tek tuşla kolayca çalıştırılabilen BiO2 ve yazılımsal özellikleri, solunum yetmezliği, post kardiyak cerrahi, kalp...

Open the catalog to page 6
Neuromonitor Catalogue - 7

Bioscope Safe Protection of Neural Functions SAFE PROTECTION OF NEURAL FUNCTIONS Neuro-monitorization It provides easy use with its user-friendly interface and design. Intraoperative farklı terapi ihtiyaçlarına (IONM) hastalaraprocess of examining the effects on nervous neuro-monitorization sahip is the Tek tuşla kolayca çalıştırılabilen BiO2 BiO2Flow system by creating electrical impulses. Electrodes are attached to certain muscle groups based on the type of surgery. The attached electrodes record your nervous system's response for electrical stimulation and display changes in your nervous...

Open the catalog to page 7
Neuromonitor Catalogue - 8

Bioscope Safe Protection of Neural Functions TECHNICAL FEATURES Bioscope Safe Protection of Neural Functions Medical Screening Technology Audio and visual feedback Input Noise Data recording and reporting Electrode status control with impedance measurement Input Impedance Artifact protection Physical Features Maximum input voltage noise of 3.2 nV/√Hz at 1 kHz 200 fA/√Hz current noise at 1 kHz 30 GΩ 3 stage sound (low, medium, high) Band Width Depth Width Input Sensitivity Display Features 10.1” sized touchscreen 1024 x 600 resolution 20-150 KuV Vertical Display Modes Hibernate (Display...

Open the catalog to page 8
Neuromonitor Catalogue - 9

BIOSCOPE Safe Protection of Neural Functions ODTÜ Teknokent 06800 Çankaya/ANKARA All rights reserved. Technical features may be changed only by Biosys Biyomedikal Mühendislik San. Ve Tic. A.Ş

Open the catalog to page 9

All Biosys catalogs and technical brochures