Biotage® Extrahera™ HV-5000
20Pages

{{requestButtons}}

Catalog excerpts

Biotage® Extrahera™ HV-5000 - 1

Your High Volume Sample Prep Workstation

Open the catalog to page 1
Biotage® Extrahera™ HV-5000 - 2

BIOTAGE SUBWAY ? ANALYTICAL LINE ORGANIC LINE SCALE-UP LINE BIOMOLECULE LINE Plasmid Construct Design Drug Design Plasmid Cloning Biotage Synthesis Sample Collection Sample Preparation Biomolecule Purification Biotage Extrahera HV-5000 | © Biotage 2022 ®

Open the catalog to page 2
Biotage® Extrahera™ HV-5000 - 3

Biotage is a Global Impact Tech Company committed to solving society’s problems. We offer workflow solutions and products to customers in drug discovery and development, analytical testing and water and environmental testing. Biotage is contributing to sustainable science with the goal to make the world healthier, greener and cleaner – HumanKind Unlimited. Our customers span a broad range of market segments including pharmaceutical, biotech, contract research and contract manufacturers as well as clinical, forensic and academic laboratories in addition to organizations focused on food...

Open the catalog to page 3
Biotage® Extrahera™ HV-5000 - 4

Meet the new member of the Biotage® Extrahera™ family Meet the new member of the Biotage Extrahera family ® The new Biotage Extrahera HV-5000, is a GLP capable, positive pressure driven sample prep workstation solution dedicated to column-based sample prep with support for classical SPE and SLE column consumable formats. ® The system caters to larger sample volumes compatible with 3, 6, 10 and 15 mL column consumables and is able to aspirate and dispense volumes from 250 – 5000 μL through each one of its 4-channel pipette tips. Like its predecessors, Extrahera Classic and Extrahera LV-200,...

Open the catalog to page 4
Biotage® Extrahera™ HV-5000 - 5

Meet the new member of the Biotage® Extrahera™ family

Open the catalog to page 5
Biotage® Extrahera™ HV-5000 - 6

Designed for high volume sample laboratories

Open the catalog to page 6
Biotage® Extrahera™ HV-5000 - 7

Biotage Extrahera HV-5000 Designed for labs who process large volume samples manually, but need the reliability and precision of automation. Forensic toxicology GLP available software supports chain of custody via audit trail management and user account management for enhanced security. ISOLUTE SLE+, HCX, HAX and EVOLUTE EXPRESS ABN, CX consumables providing high, reproducible analyte recoveries and clean extracts for reliable quantitation. ® Intuitive software interface ensures new lab personnel can use the system directly, without advanced training. The system has passed validation...

Open the catalog to page 7
Biotage® Extrahera™ HV-5000 - 8

System Overview System Overview Integral Exhaust Fan Allows for flexible installation outside or in chemical fume hood. Powerful Positive Pressure Processing Reproducible flows and elution control results in robust methods. Three Channel Waste Segregation Separation of organic, aqueous, or chlorinated waste reducing waste disposal costs. Modular Two-tier Design Minimizes footprint to increase your labs work area. Tip Configurations Position 1: Sample Tips: 24 sample tips with ability to expand to a maximum of 48 sample tips (Position 6). Position 2: Solvent Tips: 24 reusable solvent tips...

Open the catalog to page 8
Biotage® Extrahera™ HV-5000 - 9

System Overview 4 Channel Pipetting Head Extrahera [ik-strə-hϊ-rə] v. (Swedish). Reduces processing times by parallel transfer of samples or solvents from 0.25 to 5 mL. To get, pull, or draw out, usually with special effort, skill, or force; to separate or obtain a compound from a mixture by pressure, distillation, treatment with solvents, or the like. Intuitive Touch Screen Interface Easy method programming & GLP adherence. Upper Deck Processing Shelf Six positions dedicated to sample prep work flow configuration for large sample volume applications. Solvent Reservoirs (Position 5) Five...

Open the catalog to page 9
Biotage® Extrahera™ HV-5000 - 10

Seamless Workflow Seamless Workflow Biotage Extrahera HV-5000 strikes a balance between complexity and speed, and is the perfect partner for high-throughput laboratories looking for a plug-and-play sample prep automation platform without the hassles of advanced training and complicated custom configurations of a liquid handler. ® Manual Sample Preparation Semi-manual Sample Preparation Biotage Extrahera HV-5000 sample configurations ® 48 position column: 3 mL tabless tubes 24 position column: 3 & 6 mL tabless tubes 12 position columns: 10 and 15 mL tabless tubes Biotage Extrahera HV-5000...

Open the catalog to page 10
Biotage® Extrahera™ HV-5000 - 11

Seamless Workflow Biotage® Lysera Pre-treatment Biotage Lysera ® Homogenization & grinding kits for micro-organisms, hard and soft tissues, and plant tissue. Lysera Tube Carriage Kits Sample Preparation Biotage Extrahera HV-5000 ® Non-polar SPE Mixed-mode SPE Ion exchange SPE Specialty phases ISOLUTE SLE+ columns ® EVOLUTE EXPRESS SPE Columns ® Polymeric non-polar SPE Polymeric mixed-mode SPE Evaporation TurboVap Family Members for Evaporation & Concentration ®

Open the catalog to page 11
Biotage® Extrahera™ HV-5000 - 12

Configurations The Biotage Extrahera HV-5000 can process columns under a variety of configurations offering the versatility needed to adapt to different column formats and sample throughput. ® Regular Format, 24-position configuration, 6 mL Tabless Columns Regular Format, 24-position configuration, 3 mL Columns Regular Format, 12-position configuration, 10/15 mL columns Mixed Format, 48-position configuration, 3 mL Tabless Columns Extra sample tips in position 6 Mixed format, 12-position configuration, 10/15 mL Columns Biotage Extrahera HV-5000 | © Biotage 2022 ®

Open the catalog to page 12
Biotage® Extrahera™ HV-5000 - 13

Accessories We know your sample intake can vary over time and with it, your choice of column format. That’s why the Biotage Extrahera HV-5000 lets you process standard 3 and 6 mL columns in a 24 position configuration or 10 and 15 mL columns in a 12 position configuration all with the same kit. Need to increase your throughput? Batch process 48 samples with 3 mL tabless columns using the 48 position kit. ® Pressure Head Kits Pipette Tips Choose between a 24 or 48 position Dual Flow pressure head and flow through plate The 5000 µL tips are used for pipetting both sample and solvent....

Open the catalog to page 13
Biotage® Extrahera™ HV-5000 - 14

Technical Specifications Technical Specifications Liquid Handling Pipette Pump Capacity Pipetting specifications For the 5000 μL pipette tip (P/N 417007): At 250 μL: ± 2.0% accuracy and 3.0% CV At 500 μL: ±1.5% accuracy and 2.0% CV At 1000 μL: ±1.0% accuracy and 1.5% CV At 5000 μL: ±0.5% accuracy and 1.0% CV Solvent capacity 5 solvent pumps with automatic feed in from external reservoirs, with additional capacity for an extra 5 manually filled solvent reservoirs (5 x 20 mL, 5 x 40 mL, or 5 x 100 mL) Positive Pressure Unit: Pressure unit Waste Outlet Processing: 0-5 Bar (0.1 Bar Increments)...

Open the catalog to page 14