Conical Connection | B1 Biotec B1 dental implants were designed and developed as a result of a careful and creative R&D process where a wide range of dental implants were evaluated and their most exemplary features were isolated. These innovative features were then combined into a one-of-a-kind implant that stands out above the rest. Titanium Alloy - Ti 6Al 4V ELI Upper diameter Lower diameter Why choose Biotec B1 implants? Perfect sealing The B1 dental implants use a 5°-morse taper connection. This enables dental surgeons to achieve a perfectly hermetic sealing and prevent the screw from loosening....

 Open the catalog to page 2
Implants_ConicalConnection_B1-1-3

Biotec 2019 Product Catalog | 3

 Open the catalog to page 3
Implants_ConicalConnection_B1-1-4

Upper Diameter 0 3.5 mm Lower Diameter 0 2.9 mm Length Catalog Number 8.5 mm Bio-B3585 * Recommended insertion torque 35-60 Ncm * Procedure recommended by Biotec Implant Systems GmbH. Dental professionals should exercise their own judgment in each case.

 Open the catalog to page 4
Implants_ConicalConnection_B1-1-5

Upper Diameter 0 4.0 mm Lower Diameter 0 3.4 mm * Recommended insertion torque 35-60 Ncm * Procedure recommended by Biotec Implant Systems GmbH. Dental professionals should exercise their own judgment in each case. Biotec 2019 Product Catalog | 5

 Open the catalog to page 5
Implants_ConicalConnection_B1-1-6

Upper Diameter 0 4.5 mm Lower Diameter 0 3.9 mm Diameter (mm) Drill Speed (rpm) Hard Bone (D1, D2) * Recommended insertion torque 35-60 Ncm * Procedure recommended by Biotec Implant Systems GmbH. Dental professionals should exercise their own judgment in each case.

 Open the catalog to page 6
Implants_ConicalConnection_B1-1-7

Upper Diameter 0 5.0 mm Lower Diameter 0 4.4 mm * Recommended insertion torque 35-60 Ncm * Procedure recommended by Biotec Implant Systems GmbH. Dental professionals should exercise their own judgment in each case. Biotec 2019 Product Catalog | 7