video corpo

Implant System

Implant System
1 / 51 PagesView full catalog

Implant System

Product catalog summary
CEO's Message
Biotem Co. Ltd is committed to advancing dental implant technology, achieving international certifications like ISO 13485 and CE, and expanding globally. The Bio-Dental Implant System is designed to enhance safety and ease of operation for dentists while ensuring patient satisfaction.
History
Biotem's key milestones include establishing a factory in Busan in 2008, obtaining CE certification in 2009, and expanding into international markets.
Doctor's Recommendation Letter
Biotem implants are endorsed by doctors worldwide for their ease of use, high success rates, and excellent aesthetic outcomes.
Biotem Implant Surface Feature
The SLA surface of Biotem implants, created through sandblasting, reduces bacterial vulnerability and enhances osseointegration and stability.
AR | Submerged Implant System
The AR Implant System features a single pitch macro thread, Morse tapered connection, and corkscrew thread for enhanced stability and ease of use. The drilling sequence is tailored for different bone densities.
AR Drilling Sequence
Specific drilling sequences for various implant sizes and bone densities ensure precise and effective implant placement.
AR Fixture
The AR Fixture, with a tapered body and SLA surface, is recommended for placement with a torque of less than 25-30N. It is available in various diameters and lengths.
AR Abutment
The AR Abutment includes options such as healing and solid abutments, each designed for specific prosthetic applications with specified fastening torque.
AR Prosthetic Flow Chart
The flow chart outlines the sequence of components and steps involved in the prosthetic process.
Specifications
  • Abutments: Various types with specific torque recommendations, typically 20Ncm for narrow and 30Ncm for regular/wide abutments.
  • Impression Copings: Designed for use with close and custom trays, available in hex and non-hex configurations.
  • Multi Abutment Components: Include multi temporary cylinders, lab analogs, and healing caps with specific torque settings.
Procedures
  • Prosthetic Flow Charts: Outline the flow of prosthetic procedures, including various abutments and impression techniques.
  • Installation and Torque Guidelines: Emphasize correct torque application for stability and functionality.
Recommendations
  • Material Use: Recommendations for using specific materials like Ti Gr-5 for temporary cylinders.
  • Component Selection: Guidance on selecting appropriate components based on clinical scenarios.
Key Data from Tables and Charts
  • Dimensions and Codes: Tables list dimensions, product codes, and configurations for precise selection and ordering.
  • Torque Settings: Consistent torque settings ensure proper installation and function.
Critical Information
  • Fastening Torque: Adhering to specified torque settings prevents component failure.
  • Component Compatibility: Ensures compatibility with specific implant systems and configurations.
IR Tissue Level Implant System
  • Design Features: Includes single pitch and corkscrew threads for high initial stability.
  • Prosthetic Components: Variety of abutments with specific fastening torques.
  • Drilling Sequence: Detailed sequences for different fixture sizes based on bone density.
BR External Hex Implant System
  • Design Features: Corkscrew threads for synchronized threading and high initial stability.
  • Prosthetic Components: Includes cemented and angled abutments with specific torque requirements.
  • Drilling Sequence: Outlines sequences for various fixture sizes with detailed steps for different bone densities.
MR One Body Implant System
  • Drilling Sequence: Provides sequences for BOS 2.5/BOB 2.5 and BOS 3.0/BOB 3.0.
  • Components: Includes plastic impression coping, temporary caps, lab analogs, and burn-out cylinders.
Micro Thread Type Implants
  • Designed for narrow ridges, with a micro thread design to enhance chewing power.
  • Surface treated with sandblasting and acid etching (SLA).
  • Optimal insertion torque is 30Ncm.
Single Thread Type Implants
  • Mini dental implant for narrow spaces, surface treated with SLA.
  • Optimal insertion torque is 30Ncm.
MR Implant Components
  • Includes lab analog, plastic temporary cap, burn-out cylinder, and plastic impression coping.
Denture Type Implants
  • Single body, mini dental implant for denture fixation, available in 2.5 or 4mm gingival heights.
  • Optimal insertion torque is 30Ncm.
Surgical Kit Components
  • Includes various drills, drivers, and pins for surgical procedures.
Certificates and Accreditation
  • Biotem holds international certificates such as CE0120, ISO13485, and KGMP.
See more

Catalog excerpts

Implant System-2

CEO's Message Doctor's Recommendation Letter Biotem Implant Surface Feature AR | Submerged Implant System AR Implant Features AR Drilling Sequence AR Fixture AR Abutment AR Prosthetic Flow Chart AR Abutment AR Prosthetic Flow Chart AR Impression Coping AR Lab Analog AR Prosthetic Flow Chart AR Multi Abutment AR Multi Component AR Prosthetic Flow Chart AR Locator Abutment AR Abutment Locator Component AR Ball Abutment & Component SANTA & BIOARK IR | Tissue Level Implant System IR Implant Features IR Prosthetic Flow Chart IR Drilling Sequence IR Screw & Abutment IR Analog & Coping BR | External...

 Open the catalog to page 2
Implant System-3

CEO'S MESSAGE CEO'S MESSAGE Hot heads and cold hearts never solve anything Cold heads and hot hearts can solve everything! Our Company, Biotem Co. Ltd, has been working to improve and enhance dental implant technology for many years in order to provide the most satisfying product for both patients and dentists. With this accumulated experience, our technical know-how has reached a very high level. We have gained international certificates such as ISO 13485, CE together with KGMP, and we have stepped into the world-wide market. Currently, Korea’s standard of dental implant technology is one of...

 Open the catalog to page 3
Implant System-4

Korea DIDEX exhibition participation Russia Certificate Participated in WCUPS in Philippines (Contract with agency of Philippines) AEEDC(DUBAI Exhibition) (Contract with agency of Iraq, Egypt) Japan Certificate 필리핀 보라카이 세계초음파학회 참가 (필리핀 에이전시 계약체결) Live Surgery in Hochiminh, Vietnam Participated in WCUPS in Netherland Germany Cologne IDS Exhibition Participation (Contract with agency of Russia) Phuket Thailand BIOTEM World Symposium F.D.A Certificate Korea DIDEX exhibition participation Germany Cologne IDS exhibition participation. (Contract with agency of Portugal, Italy, Jordan, Swiss etc.) Participated...

 Open the catalog to page 4
Implant System-5

DOCTOR'S RECOMMENDATION LETTER DOCTOR'S RECOMMENDATION LETTER Dr. Raymond | Lebanon After working with implants for over 15 years, I discovered that Biotem implants’quality and user-friendliness match the best international products, they provide high satisfication and top performance. Prof. Sohn | Daegu Catholic University Dental clinic from Korea I have experienced over than 20 years of implant and Biotem implant is one of the best solution to the patients as it is very easy to surgery, good result of symptoms and most fittable to the prosthetic process. Dr. Eric Park | U.S.A After placing...

 Open the catalog to page 5
Implant System-6

BIOTEM IMPLANT SURFACE FEATURE X 500 SANDBLASTED, LARGE-GRIT, ACID-ETCHED The SLA surface is produced by a large grit sand-blasting. The surface is not microporous and therefore provides no enclosed volumes to reduce vulnerability to bacteria. This method analyses the first few atomic layers of the surface, and thus the chemical composition of the material which is in direct contact and interacts with tissue fluids and cells. Biotem Implant Surface Feature

 Open the catalog to page 6
Implant System-7

AR | Submerged Implant System FXAR 3.4 | Drilling Sequence ASTFA 3.5 / FXAR 3.7 | Drilling Sequence ASTFA 4.0 / FXAR 4.0 | Drilling Sequence ASTFA 4.5 / FXAR 4.5 | Drilling Sequence ASTFA 5.0 / FXAR 5.0 | Drilling Sequence ASTFA 6.0 / FXAR 6.0 | Drilling Sequence Non-Micro Thread AR Fixture | SLA Tapered AR Fixture | SLA Cover Screw Healing Abutment Solid Abutment Cemented Abutment (Hex) Cemented Abutment (Non-Hex) Milling Abutment (Hex) Temporary Abutment (Hex) Temporary Abutment (Non-Hex) Angled Abutment (Hex) A-Type Angled Abutment (Hex) B-Type Angled Abutment (Non-Hex) Ti-base Abutment Transfer...

 Open the catalog to page 7
Implant System-8

AR | Submerged Implant System FXAR 3.4 | Drilling Sequence Single Pitch Macro Thread • 0.7pitch x 0.15depth x double thread • Synchronized thread • Optimized design for (SLA/RBM) surface • Reinforce fixture strength Morse Tapered Connection 11 • The Fixture & Abutment interface ensures hermetic sealing • This distributes the load to the fixture evenly. Therefore, it minimized bone loss Bone Density Point Drill Soft Normal Ø3.4 Fixture Implant Placement ASTFA 3.5 / FXAR 3.7 | Drilling Sequence Corkscrew Thread Taper degree 1.5 • Easy to get initial stability in soft bone • Powerful self threading...

 Open the catalog to page 8
Implant System-9

ASTFA 4.5 / FXAR 4.5 | Drilling Sequence Non-Micro Thread AR Fixture | SLA • No Mount System : Using a special fixture driver with more durability and easy separation-connection to fixture • Surface : SLA • Recommended placement torque : Less than 25~30N • Tapered body for maxillary L Y-Dim (0.7) Bone Density Soft Normal Point Drill Ø4.5 Fixture Implant Placement ASTFA 5.0 / FXAR 5.0 | Drilling Sequence Bone Density Soft Normal Point Drill F5.0 Cortical Drill Ø5.0 Fixture Implant Placement ASTFA 6.0 / FXAR 6.0 | Drilling Sequence Bone Density Point Drill Soft Normal Hard Submerged Implant System...

 Open the catalog to page 9
Implant System-10

Cover Screw • Ø 4.0, Ø 5.0 fixture : Expanded Platform (Ø 3.4 fixture is excluded) • No Mount System : Using a special fixture driver with more durability and easy separation-connection to fixture • Surface : SLA • Recommended placement torque : Less than 25~30N Healing Abutment • Using a 1.2 Hex Driver • Fastening torque : 5~8Ncm • H=From Fixture platform to top D Submerged Implant System

 Open the catalog to page 10
Implant System-11

AR PROSTHETIC FLOW CHART Solid / Cemented Abutment Level Impression Solid Abutment • An abutment combined with a set screw, for a bridge prosthesis • Using a 1.2 Hex Driver • Fastening torque : Narrow 20Ncm Regular / Wide 30Ncm • Protective cap included except Ø 4.0 D Ø4.5 Plastic Impression Coping D Ø5.5 Cemented Abutment 1.2 Hex Driver Cover Screw Healing Abutment Outer Driver Solid Outer Driver • Solid Abutment protection with reduced patient discomfort • Used as a temporary crown base Submerged Implant System

 Open the catalog to page 11
Implant System-12

AR PROSTHETIC FLOW CHART Cemented/ Angled / Milling / Temporary Fixture Level Impression • An abutment for a single prosthesis. • Using a 1.2 Hex Driver • Fastening torque : Narrow 20Ncm Regular / Wide 30Ncm • Protect cap is optional Angled Abutment Milling Abutment Temporary Abutment SAAT 30514 MSA SAAT 30524 MSA SAAT 30534 MSA SAAT 30544 MSA SAAT 30515 MSA SAAT 30525 MSA SAAT 30535 MSA SAAT 30545 MSA SAAT 30517 MSA SAAT 30527 MSA SAAT 30537 MSA SAAT 30547 MSA Transfer Type Pick-up Type 1.2 Hex Driver Cover Screw Abutment Screw M 2.0 (AAHS 2083 Ebony) Abutment Screw M 1.6 (AAHS 1687 Gold) Abutment...

 Open the catalog to page 12

All BIOTEM.Co.,Ltd catalogs and technical brochures

  1. MRCatalogue

    9  Pages

  2. SANTA / BIOARK

    14  Pages

  3. DENTAL IMPLANT

    44  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.