Introduction
The AngioSculpt PTCA Scoring Balloon Catheter is an innovative device designed for vascular intervention, specifically targeting complex coronary artery lesions. It features a unique nitinol scoring element that enhances precision and safety during procedures.

Specifications
The catheter is equipped with a flexible nitinol scoring element with three rectangular spiral struts, working in tandem with a semi-compliant balloon. It fits into a 6F guiding catheter and is compatible with a 0.014” guide wire. The balloon diameters range from 2.0 to 3.5 mm, with lengths of 10, 15, and 20 mm. The rated burst pressure varies by size, with a maximum of 20 atm for smaller diameters.

Procedures and Performance
The device is designed to score the target lesion with precision, reducing the risk of slippage and ensuring accurate placement. It has been clinically proven to have a significantly lower dissection rate compared to Plain Old Balloon Angioplasty (POBA), with a rate of 13.6% versus approximately 30% for POBA.

Clinical Efficacy
AngioSculpt is the only plaque-modifying device approved for treating C type lesions. It has demonstrated superior outcomes in terms of luminal gain, achieving a 33% greater gain than conventional balloons and a 50% greater gain than direct stenting.

Recommendations
For optimal results, it is recommended to refer to the AngioSculpt Instructions for Use (IFU) to select the appropriate device size. The device is particularly effective for fibro-calcified, bifurcation, and ostial lesions, as well as complex type B2/C lesions and in-stent restenosis.

Conclusion
The AngioSculpt Scoring Balloon Catheter offers a new dimension in lesion preparation, providing better final post-stent dimensions and improved patient outcomes. Its innovative design and proven clinical efficacy make it a valuable tool in vascular intervention.
See more

Catalog excerpts

AngioSculpt PTCA-1

Vascular Intervention AngioSculpt Changing the Landscape Innovation by Design Flexible nitinol scoring element with three rectangular spiral struts works ··Precise Control: The rectangular shaped nitinol scoring element results in a more precise and predictable outcome. in tandem with a semi-compliant balloon to score the target lesion. Semi Compliant Balloon Allows the physician to tailor Helical scoring element with ··Targeted Treatment: No device slippage ensures more accurate placement and therefore no healthy tissue damage. Safe rectangular scoring edge. Balloon inflation focuses uniform radial forces along the edges of the nitinol element. ··Clinically proven to be safe and effective with significantly lower dissection rate than POBA. ··Only plaque modifying device approved to treat C type lesions. Scoring Elements Electropolished struts provide a margin of safety, resulting in zero perforations and no slippage1. Excellent Rewrap Profile Manufacturer: AngioScore, Inc. 5055 Brandin Court Fremont, CA 94538 USA Nitinol enhanced deflation for excellent rewrap and recross capabilities. Low Crossing Profile All devices fit into a Please refer to AngioSculpt Instructions for Use (IFU) to select the appropriate device size. 6F guiding catheter. © BIOTRONIK AG® All rights reserved. Specifications are subject to modification, revision and improvement. Distributor: BIOTRONIK AG Ackerstrasse 6 8180 Bülach · Switzerland Tel +41 (0) 44 8645111 Fax +41 (0) 44 8645005 [email protected] www.biotronik.com Scoring Balloon Catheter AngioSculpt AngioSculpt PTCA Scoring Balloon Catheter Changing the Landscape

 Open the catalog to page 1
AngioSculpt PTCA-2

A New Dimension in Patient Outcomes A New Dimension in Lesion Preparation Product Specifications Balloon Scoring Elements Material Spiral nitinol «scoring» wires Number of scoring elements Shape of scoring element Profile of scoring element Rapid Exchange Catheter Balloon coating As demonstrated in clinical studies, AngioSculpt was The AngioSculpt Scoring Balloon Catheter is a unique product, offering an innovative Guiding catheter Guide wire diameter 0.014” guide wire compatible 137 cm Crossing profile nitinol scoring element which scores the plaque circumferentially and provides a precise used...

 Open the catalog to page 2

All Biotronik catalogs and technical brochures

  1. Pantera Pro

    5  Pages

  2. 3Flow

    2  Pages

  3. Pulsar-18

    6  Pages

  4. Passeo-35 HP

    4  Pages

  5. Passeo-35

    3  Pages

  6. Passeo-18

    3  Pages

  7. Passeo-14

    3  Pages

  8. Astron

    4  Pages

Archived catalogs

  1. Pantera LEO

    5  Pages

  2. Lumax 740

    1  Page

  3. BioMonitor

    8  Pages

  4. Protego

    6  Pages

  5. Idova 7

    8  Pages

  6. PRO-Kinetic

    12  Pages

  7. Magnum

    2  Pages

  8. Galeo

    8  Pages

  9. Streamer

    2  Pages

  10. Pacemaker

    48  Pages

  11. PK Papyrus

    4  Pages

  12. Fortress

    3  Pages

  13. Galeo Pro

    2  Pages

  14. Magmaris

    6  Pages

  15. Orsiro

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.