video corpo

Astron

Astron

Astron

Product catalog summary
Overview: The Astron stent is a clinically proven self-expanding stent system designed for the treatment of iliac disease. It features a segmented stent design with specific strut thickness to ensure adequate chronic outward force in the iliac region. The stent's peak-to-valley design and S-articulating connecting bars provide flexibility and prevent fish-scaling in tortuous arteries.
Key Features:
  • proBIO Coating: The stent is coated with proBIO, which acts as a barrier to reduce the release of nickel and other heavy metal ions, enhancing patient safety.
  • Enhanced Visibility: The stent includes four gold markers at each end to improve radiopacity.
  • Delivery System: The pull-back delivery system simplifies stent deployment, and a safety tab prevents accidental deployment. The system includes a 6F distal shaft and a 5.2F proximal shaft, allowing for contrast injection while the device is in place.
Indications: The Astron stent is indicated for patients with atherosclerotic disease of the iliac arteries and for treating insufficient results after percutaneous transluminal angioplasty (PTA), such as residual stenosis and dissection.
Technical Specifications:
  • Catheter Type: OTW
  • Recommended Guide Wire: 0.035”
  • Stent Material: Nitinol
  • Strut Thickness: 225 μm (ø 10 mm = 230 μm)
  • Stent Coating: proBIO (Amorphous Silicon Carbide)
  • Stent Markers: 4 gold markers each end
  • Sizes: Diameter 7 - 10 mm; Length 30 - 80 mm
  • Proximal Shaft: 5.2F, hydrophobic coating
  • Usable Length: 70 and 120 cm
Ordering Information: The stent is available in various sizes and lengths, with specific catalog numbers for each configuration. The catheter lengths are available in 70 cm and 120 cm, with stent lengths ranging from 30 mm to 80 mm.
Contact Information: BIOTRONIK AG, Ackerstrasse 6, 8180 Bülach, Switzerland. Tel: +41 (0) 44 8645111, Fax: +41 (0) 44 8645005, Email: [email protected], Website: www.biotronik.com
See more

Catalog excerpts

Astron-1

Pull-back delivery system for simple stent deployment Clinically proven stent for the treatment of iliac disease 5.2F proximal shaft for contrast injection with device in sheath Technical data / ordering info Vascular Intervention // Coronary BIOTRONIK Self-Expanding Stent System/0.0357OTW W excellence for life

 Open the catalog to page 1
Astron-2

Clinically proven stent for the 1 treatment of iliac disease • Segmented stent design and strut thickness to provide sufficient chronic outward force in the iliac territory. • Peak-to-valley design and S-articulating connecting bars provide multi-directional flexibility and avoid fish-scaling in tortuous arteries. Enhanced visibility 4 gold markers at each end provide enhanced radiopacity proBIO reduces ion release proBIO acts as an effective and reliable barrier to nickel and other heavy metal ion diffusion. 1 day Astron stent proBIO coated Astron stent non-coated

 Open the catalog to page 2
Astron-3

Pull-back delivery system for simple 3 stent deployment Easy release Relieves friction of introducer valve on the retractable shaft during stent deployment, providing a smoother action. Pull-back delivery system Enables simple stent deployment. Safety tab Designed to prevent accidental stent deployment. 5.2F proximal shaft for contrast 4 injection with device in sheath 6F distal shaft with a 5.2F proximal shaft allows contrast injection while the device is positioned inside the introducer and across the lesion.

 Open the catalog to page 3
Astron-4

Vascular Intervention Peripheral Indicated for use in patients with atherosclerotic disease of the iliac arteries and for the treatment of insufficient results after percutaneous transluminal angioplasty (PTA), e.g. residual stenosis and dissection. Catheter type OTW Recommended guide wire 0.035” Stent material Nitinol Stent coating proBIO (Amorphous Silicon Carbide) Stent markers 4 gold markers each end Proximal shaft 5.2F, hydrophobic coating Stent Catheter length 70 cm Ordering Information 0 (mm) Stent length (mm) 1. BIOFLEX I Astron Clinical Report; 2. Nickel release...

 Open the catalog to page 4

All Biotronik catalogs and technical brochures

  1. Pantera Pro

    5  Pages

  2. 3Flow

    2  Pages

  3. Pulsar-18

    6  Pages

  4. Passeo-35 HP

    4  Pages

  5. Passeo-35

    3  Pages

  6. Passeo-18

    3  Pages

  7. Passeo-14

    3  Pages

Archived catalogs

  1. Pantera LEO

    5  Pages

  2. Lumax 740

    1  Page

  3. BioMonitor

    8  Pages

  4. Protego

    6  Pages

  5. Idova 7

    8  Pages

  6. PRO-Kinetic

    12  Pages

  7. Magnum

    2  Pages

  8. Galeo

    8  Pages

  9. Streamer

    2  Pages

  10. Pacemaker

    48  Pages

  11. PK Papyrus

    4  Pages

  12. Fortress

    3  Pages

  13. Galeo Pro

    2  Pages

  14. Magmaris

    6  Pages

  15. Orsiro

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.