Overview: The document provides technical data and ordering information for the Orsiro Drug-Eluting Stent System, highlighting its clinical efficacy, technical specifications, and ordering details.
Clinical Efficacy: Orsiro stents have demonstrated low target lesion failure (TLF) rates in various clinical trials, outperforming other drug-eluting stents (DES) like Xience. The stent system is particularly effective in challenging subgroups such as STEMI patients, small vessels, and diabetics, with a 0.0% stent thrombosis rate over 60 months in some studies.
Technical Specifications: The stent is made from cobalt chromium with a passive proBIO coating and an active BIOlute bioabsorbable coating that elutes a limus drug. It features ultrathin 60 μm struts for improved re-endothelialization and reduced restenosis risk. The delivery system includes a rapid exchange catheter with a hydrophilic coating and platinum-iridium marker bands.
Performance Metrics: Orsiro stents require up to 68% less force to cross demanding anatomies and have a 13% lower crossing profile compared to competitors. They also transmit 57% more force from hub to tip, enhancing pushability.
Ordering Information: The document provides detailed ordering codes for various stent sizes and lengths, with specifications for catheter length, balloon material, and pressure ratings.
Conclusion: The Orsiro stent system is positioned as a highly deliverable and clinically proven option for coronary interventions, offering superior performance in terms of ease of delivery, clinical outcomes, and structural integrity.
See more

Catalog excerpts

Orsiro-1

Clinically proven Highly deliverable Vascular Intervention // Coronary Drug-Eluting Stent System Technical data / ordering info

 Open the catalog to page 1
Orsiro-2

Clinically proven Extensive clinical program* >32,500 patients enrolled >50,500 patients planned in total >44 studies ongoing >55 studies planned in total Outstanding clinical results even in challenging subgroups Orsiro has demonstrated consistently low target lesion failure (TLF) in all-comers trials compared to major modern drug-eluting stents (DES). Orsiro BIOTRONIK Synergy Boston Scientific Resolute Integrity Medtronic Orsiro BIOTRONIK Xience Prime/ Xpedition Abbott Orsiro BIOTRONIK Nobori Terumo Small vessels patients planned in total

 Open the catalog to page 2
Orsiro-3

The new benchmark for DES BIOFLOW-V 12-month clinical outcomes compared to Xience In a post-hoc analysis of pooled patient-level data from three RCTs, Orsiro achieved a 96.9% probability of superiority* on TLF rate versus Xience.10 BIOFLOW-V / -IV / -II Bayesian Population (n=2,208) Orsiro BIOTRONIK Xience Abbott * osterior probability, Bayesian analytical methods were applied P Proven long term clinical outcomes All stents implanted from 2007 until January 11, 2017 unadjusted (SCAAR)11,12 Cumulative rate of restenosis (%) (includes stent thrombosis) Orsiro showed a lower restenosis rate than...

 Open the catalog to page 3
Orsiro-4

Highly deliverable Designed for challenging cases, the Orsiro stent system provides better push and easier cross with a lower crossing profile. Better push Transmitting up to 57%13 more force from 14 hub to tip. Orsiro BIOTRONIK Resolute Onyx Medtronic better push Xience Xpedition Abbott Synergy Boston Scientific 0 Easier cross Up to 68% less force needed to successfully cross demanding anatomies. 15,16 Orsiro BIOTRONIK Xience Xpedition Abbott less force required Synergy Boston Scientific Resolute Onyx Medtronic 0.05 Lower crossing profile Improved acute performance - up to 13% lower 15 crossing...

 Open the catalog to page 4
Orsiro-5

Orsiro BIOTRONIK Thinner struts make the difference Thinner struts create: • Less disrupted flow18 • Less arterial injury18 Synergy Boston Scientific PtCr-EES Which leads to: 18 • Improved re-endothelialization 18 • Reduced risk of restenosis and thrombosis Ultimaster Terumo The thinner the better, as long as the 18 radial force can be maintained Up to 15% more radial strength scaffolding once implanted. Orsiro BIOTRONIK Synergy Boston Scientific Resolute Onyx Medtronic CoNi-ZES Xience Family Abbott CoCr/EES more radial strength Promus Boston Scientific PtCr-EES

 Open the catalog to page 5
Orsiro-6

Vascular Intervention Coronary Indicated for discrete de novo stenotic lesions and in-stent restenotic lesions.* Technical Data Stent Stent material Passive coating Active coating Drug dose Strut thickness Delivery system Catheter type Recommended guide catheter Lesion entry profile Guide wire diameter Usable catheter length Balloon material Coating (distal shaft) Marker bands Proximal shaft diameter Distal shaft diameter Nominal pressure (NP) Rated burst pressure (RBP) Compliance Chart Nominal Pressure (NP) Rated Burst Pressure (RBP) Ordering Information Cobalt chromium, L-605 proBIO (Amorphous...

 Open the catalog to page 6

All Biotronik catalogs and technical brochures

  1. Pantera Pro

    5  Pages

  2. 3Flow

    2  Pages

  3. Pulsar-18

    6  Pages

  4. Passeo-35 HP

    4  Pages

  5. Passeo-35

    3  Pages

  6. Passeo-18

    3  Pages

  7. Passeo-14

    3  Pages

  8. Astron

    4  Pages

Archived catalogs

  1. Pantera LEO

    5  Pages

  2. Lumax 740

    1  Page

  3. BioMonitor

    8  Pages

  4. Protego

    6  Pages

  5. Idova 7

    8  Pages

  6. PRO-Kinetic

    12  Pages

  7. Magnum

    2  Pages

  8. Galeo

    8  Pages

  9. Streamer

    2  Pages

  10. Pacemaker

    48  Pages

  11. PK Papyrus

    4  Pages

  12. Fortress

    3  Pages

  13. Galeo Pro

    2  Pages

  14. Magmaris

    6  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.