video corpo

Pantera Pro
5Pages

{{requestButtons}}

Catalog excerpts

Pantera Pro - 1

Lowest crossability in tight lesions 43% less friction during kissing balloon technique 38% more push to reach target lesion Vascular Intervention // Coronary Semi-Compliant Workhorse Balloon Catheter Technical data / ordering info

Open the catalog to page 1
Pantera Pro - 2

Lowest crossability in tight lesions Slim shoulders and hydrophilic coating Proprietary balloon material for small sizes allows for slim shoulders while maintaining durability. Coupled with hydrophilic balloon coating, Pantera Pro excels in tight lesions. Hydrophilic coating Slim shoulders Slim shoulders Excellent visibility platinum iridium markers

Open the catalog to page 2
Pantera Pro - 3

43% less friction during kissing balloon technique 2 Reduced distal shaft profile The reduced distal shaft profile lowers friction when using two balloons in a 6F guiding catheter.* Lowest friction during kissing balloon technique compared to main competitors Pantera Pro BIOTRONIK Trek Abbott Emerge Boston Scientific Mean force to introduce second 3.0 /20 balloon (N) *Any combination of two diameters not larger than 3.5 mm within a 6F guiding catheter with a minimal inner diameter of 0.070”/1.78 mm.

Open the catalog to page 3
Pantera Pro - 4

38% more push to reach target lesion 3 Enhanced Force Transmission shaft BIOTRONIK’s unique Enhanced Force Transmission shaft results in optimal pushability due to the direct transition from proximal metallic hypotube to distal guide wire support section. Pantera Pro Guide wire Direct connection Metallic hypotube shaft Guide wire support section Guide wire Metallic hypotube shaft Intermediate shaft Guide wire support section Pushability comparison Pantera Pro BIOTRONIK Mini Trek Abbott Emerge Boston Scientific

Open the catalog to page 4
Pantera Pro - 5

Vascular Intervention Coronary Indicated for dilation of coronary artery or bypass graft stenosis.* Technical Data Proximal shaft Design Diameter Shaft markers Distal shaft Guiding catheter Guide wire diameter Lesion entry profile Usable length Balloon material Balloon folding Balloon markers Coating distal shaft Balloon and tip coating Kissing balloon technique Diameter Compliance Chart Nominal Pressure (NP) Rated Burst Pressure (RBP) Hypotube design 2.0F 92 cm and 102 cm from tip 5F (min. I.D. 0.056”/1.42 mm) 0.014” 0.017” 140 cm Semi Crystalline Co-Polymer ø 1.25 - 1.5 mm: Two-fold; ø...

Open the catalog to page 5

All Biotronik catalogs and technical brochures

  1. Orsiro

    6 Pages

  2. 3Flow

    2 Pages

  3. Magmaris

    6 Pages

  4. Passeo-35 HP

    4 Pages

  5. Pulsar-18

    6 Pages

  6. Galeo Pro

    2 Pages

  7. Fortress

    3 Pages

  8. Passeo-35 HP

    3 Pages

  9. Passeo-35

    3 Pages

  10. Passeo-18

    3 Pages

  11. Passeo-14

    3 Pages

  12. PK Papyrus

    4 Pages

  13. Astron

    4 Pages

  14. Pantera LEO

    5 Pages

  15. Lumax 740

    1 Pages

  16. BioMonitor

    8 Pages

  17. Protego

    6 Pages

  18. Idova 7

    8 Pages

  19. PRO-Kinetic

    12 Pages

  20. Magnum

    2 Pages

  21. Galeo

    8 Pages

  22. Streamer

    2 Pages

  23. Pacemaker

    48 Pages