PRO-Kinetic Energy - 1

Clinically proven results Ultrathin struts Exceptional deliverability Technical data / ordering info Vascular Intervention // Coronary Cobalt Chromium Coronary Stent System Pro-Kinetic Energy

Open the catalog to page 1
PRO-Kinetic Energy - 2

Clinically proven results Numerically, the lowest TVF* of 9.06% across FDA IDE studies from leading BMS 1 competitors. BIOHELIX-I2 BIOTRONIK Driver Registry 3 Medtronic OMEGA Trial4 Boston Scientific Vision Registry 5 Abbott Double helix stent design for a smooth outer contour and outstanding flexibility Longitudinal connectors designed to resist longitudinal compression Wedge shaped transitions provide consistent scaffolding 60 μm * arget Vessel Failure rate as a composite of Cardiac T Death, Myocardial Infarction (MI) and ischemia-driven Target Vessel Revascularization.

Open the catalog to page 2
PRO-Kinetic Energy - 3

Thinnest struts among major modern BMS Ultrathin struts Struts of only 60 μm result in exceptional flexibility and deliverability of the stent in even the most challenging anatomy.6 PRO-Kinetic Energy 6 BIOTRONIK The lowest bending stiffness for outstanding flexibility. PRO-Kinetic Energy BIOTRONIK Rebel Boston Scientific Rebel Boston Scientific Integrity Medtronic Integrity Medtronic Radial strength Double Helix stent design maintains sufficient radial strength with thin strut design and provides stability for optimal scaffolding and support. Multi-Link 8 Abbott thinner than Rebel...

Open the catalog to page 3
PRO-Kinetic Energy - 4

Exceptional deliverability Expect effortless deliverability from the stent delivery system featuring an Enhanced Force Transmission shaft and thinner materials for added pushability and trackability. Ultrathin struts and advanced crimping for a minimized crossing profile. PRO-Kinetic Energy BIOTRONIK Rebel Boston Scientific Integrity Medtronic Profile of crimped stent Diameter (mm) Exceptional pushability with Enhanced Force Transmission shaft. Multi-Link 8 Abbott Integrity Medtronic Rebel Boston Scientific PRO-Kinetic Energy BIOTRONIK

Open the catalog to page 4
PRO-Kinetic Energy - 5

PRO-Kinetic Energy Indicated for improving coronary luminal diameter.* Technical Data Stent Stent material Passive coating Strut thickness Delivery system Catheter type Recommended guide catheter Lesion entry profile Guide wire diameter Usable catheter length Balloon material Coating (distal shaft) Marker bands Proximal shaft diameter Distal shaft diameter Nominal pressure (NP) Rated burst pressure (RBP) Compliance Chart Nominal Pressure atm** (NP) ø (mm) Rated Burst atm** Pressure (RBP) ø (mm) Ordering Information Vascular Intervention Coronary Cobalt chromium, L-605 proBIO (Amorphous...

Open the catalog to page 5

All Biotronik catalogs and technical brochures

  1. Orsiro

    6 Pages

  2. Pantera Pro

    5 Pages

  3. 3Flow

    2 Pages

  4. Magmaris

    6 Pages

  5. Passeo-35 HP

    4 Pages

  6. Pulsar-18

    6 Pages

  7. Galeo Pro

    2 Pages

  8. Fortress

    3 Pages

  9. Passeo-35 HP

    3 Pages

  10. Passeo-35

    3 Pages

  11. Passeo-18

    3 Pages

  12. Passeo-14

    3 Pages

  13. PK Papyrus

    4 Pages

  14. Astron

    4 Pages

  15. Pantera LEO

    5 Pages

  16. Lumax 740

    1 Pages

  17. BioMonitor

    8 Pages

  18. Protego

    6 Pages

  19. Idova 7

    8 Pages

  20. PRO-Kinetic

    12 Pages

  21. Magnum

    2 Pages

  22. Galeo

    8 Pages

  23. Streamer

    2 Pages

  24. Pacemaker

    48 Pages